Establishment of institutional diagnostic reference levels for 6 adult computed tomography examinations: Results from preliminary data collection

被引:6
|
作者
Albahiti, Sarah K. [1 ]
Barnawi, Rashid A. [1 ]
Alsafi, Khalid [1 ]
Khafaji, Mawya [1 ]
Aljondi, Rowa [2 ]
Alghamdi, Salem Saeed [2 ]
Awan, Zuhier [3 ,4 ]
Sulieman, Abdelmoneim [5 ,6 ]
Jafer, Mustafa [2 ]
Tamam, Nissren [7 ]
Tajaldeen, Abdulrahman [8 ]
Mattar, Essam H. [9 ]
Al-Malki, Khaled Mudis [10 ]
Bradley, David [11 ,12 ]
机构
[1] King Abdulaziz Univ, Dept Radiol, Fac Med, Jeddah, Saudi Arabia
[2] Univ Jeddah, Dept Appl Radiol Technol, Coll Appl Med Sci, Jeddah, Saudi Arabia
[3] Univ Jeddah, Dept Clin Biochem, Fac Med, Jeddah, Saudi Arabia
[4] King Abdulaziz Univ, Dept Clin Biochem, Fac Med, Jeddah, Saudi Arabia
[5] Prince Sattam bin Abdulaziz Univ, Radiol & Med Imaging Dept, Coll Appl Med Sci, POB 422, Alkharj 11942, Saudi Arabia
[6] Sudan Univ Sci & Technol, Dept Basic Sci, Coll Med Radiol Sci, POB 1908, Khartoum, Sudan
[7] Princess Nourah bint Abdulrahman Univ, Dept Phys, Coll Sci, POB 84428, Riyadh 11671, Saudi Arabia
[8] Imam Abdulrahman Bin Faisal Univ, Dept Radiol Sci, Coll Appl Med Sci, Dammam 34212, Saudi Arabia
[9] King Saud Univ, Dept Radiol Sci, Coll Appl Med Sci, POB 10219, Riyadh 11433, Saudi Arabia
[10] King Abdulaziz Univ, Dept Phys, Fac Sci, Jeddah, Saudi Arabia
[11] Sunway Univ, Sch Engn & Technol, Ctr Appl Phys & Radiat Technol, Bandar Sunway 47500, Selangor, Malaysia
[12] Univ Surrey, Dept Phys, Ctr Nucl & Radiat Phys, Guildford GU2 7XH, Surrey, England
关键词
Radiology; Diagnostic reference levels; Dose -length product; CT dose Index; Computed tomography; PATIENT; CHEST;
D O I
10.1016/j.radphyschem.2022.110477
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Computed tomography (CT) is the leading source of the cumulative effective doses to the general populace from medicinal and artificial sources. With the increased use of CT examinations comes the concern regarding the health effects of unnecessary radiation exposure and the need to optimize the doses that patients receive. The current study evaluates the patients' doses during specific CT procedures and establishes institutional diagnostic reference levels (DRLs) for the frequent CT scans performed. 8156 CT scan examinations were performed during three years from 2015 to 2018 using a single CT scan machine at our institution. Data from the six most common examinations were analyzed. The volume CT dose index (CTDIvol (mGy)) and dose length product (DLP) distribution's median and 75th percentile values were computed. The results were descriptively compared with DRLs from different countries and regions. The six most common examinations constituted 5815 studies. We established our DRLs as the median value of CTDIvol (mGy)| and DLP (mGy x cm) as follows: CT of the brain: 35.0 mGy and 839 mGyx cm, respectively; chest with contrast: 4 mGy and 148 mGy-cm, respectively; chest without contrast: 5 mGy and 190 mGy-cm, respectively; abdomen and pelvis with contrast: 8 mGy and 636 mGy-cm, respectively; abdomen and pelvis without contrast 8 mGy and 568 mGy-cm, in that order; abdomen, pelvis, and kidneys: 11 mGy and 458 mGyx cm, respectively. Our values for brain and chest CTs were lower than the international DRLs, while those for abdominal imaging were higher. The established DRLs offer an opportunity for us to optimize the dose delivered to patients and compare them to the national benchmarks when they are issued. The study revealed that CT dose showed wide discrepancies for the same procedures at the department levels suggesting that the practice was neither optimized nor harmonized. Therefore, DRL should be reassessed after the operators' training and awareness to reduce the patients' dose and related radiogenic risk to its minimal value.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Establishment of diagnostic reference levels in low-dose renal computed tomography
    Rawashdeh, Mohammad
    Saade, Charbel
    ACTA RADIOLOGICA, 2023, 64 (02) : 829 - 836
  • [22] Diagnostic Reference Levels for computed tomography in Austria: A 2018 nationwide survey on adult patients
    Wachabauer, David
    Roethlin, Florian
    Moshammer, Hanns Michael
    Homolka, Peter
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 125
  • [23] Local Diagnostic Reference Levels for Common Adult Computed Tomography Procedures in Addis Ababa
    Dellie, Seife Teferi
    Tesfaw, Ambaye Fisehaw
    Kumsa, Marema Jebessa
    Tolawak, Birhanu Turi
    DOSE-RESPONSE, 2023, 21 (02):
  • [24] Systematic Review on Diagnostic Reference Levels for Computed Tomography Examinations in Radiation Therapy Planning
    Rao, Shreekripa
    Sharan, Krishna
    Sukumar, Suresh
    Chandraguthi, Srinidhi Gururajarao
    Nisha Dsouza, Rechal
    David, Leena R.
    Ravichandran, Sneha
    Uzun, Berna
    Kadavigere, Rajagopal
    Uzun Ozsahin, Dilber
    DIAGNOSTICS, 2023, 13 (06)
  • [25] Estimation of radiation dose and establishment of local diagnostic reference levels for computed tomography of head in pediatric population
    Priyanka
    Kadavigere, Rajagopal
    Sukumar, Suresh
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (05) : 983 - 991
  • [26] Establishment of national diagnostic reference levels for radiotherapy computed tomography simulation procedures in Slovenia
    Zalokar, Nika
    Marcius, Valerija Zager
    Mekis, Nejc
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 127
  • [27] Development of size-specific institutional diagnostic reference levels for computed tomography protocols in neck imaging
    Steuwe A.
    Thomas C.
    Kraus B.
    Bethge O.T.
    Aissa J.
    Klosterkemper Y.
    Antoch G.
    Boos J.
    Journal of Radiological Protection, 2020, 40 (01) : 68 - 82
  • [28] Diagnostic reference levels of paediatric computed tomography examinations performed at a dedicated Australian paediatric hospital
    Bibbo, Giovanni
    Brown, Scott
    Linke, Rebecca
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (04) : 475 - 484
  • [29] Establishment of institutional diagnostic reference level for Computed Tomography dose on 160 slicer Computed Tomography scan at Lady Reading Hospital Peshawar
    Khan, Muhammad Imran
    Khan, Muhammad Zeeshan
    Afzal, Fariha
    Zenab
    Khan, Shandana
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2023, 73 (04) : 808 - 811
  • [30] Establishment of Diagnostic Reference Levels and Evaluation of Radiation Dose in Double Phase Abdominopelvic Computed Tomography
    Keshtkar M.
    Iranian Journal of Medical Physics, 2023, 20 (02) : 80 - 86