Experimental measurement of thermal transmittance in reinforced concrete buildings

被引:0
作者
Evola, Gianpiero [1 ]
Marletta, Luigi [1 ]
Marino, Concettina [2 ]
Nucara, Antonino [2 ]
Panzera, Maria Francesca [2 ]
Pietrafesa, Matilde [2 ]
Taverriti, Annunziato Massimo [2 ]
Tronchin, Lamberto [3 ]
机构
[1] Univ Catania, Dept Elect Elect & Comp Engn, Catania, Italy
[2] Univ Reggio Calabria, Dept Civil Energy Environm & Mat Engn Mediterrane, Reggio Di Calabria, Italy
[3] Univ Bologna, Dept Archtecture, Bologna, Italy
来源
2020 20TH IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2020 4TH IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC/I&CPS EUROPE) | 2020年
关键词
NZEB; thermal transmittance measurement; Hotbox method; building envelope; building typology; IN-SITU;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To reduce the incidence of greenhouse gas emissions, radical measures need to be adopted in the most pollutant sectors, among which the building one, where actions can be undertaken, involving both the passive (envelope) and the active (thermal plants) sections. In this framework, the aim of this paper was to elaborate and test a suitable procedure to measure one of the characteristic parameters of the envelope, the thermal transmittance of the opaque components. A codified procedure has been exploited, using instruments and experimental techniques able to overcome most of the drawbacks (e.g. long period of measurement) which often have to be dealt with, during field measurement of thermal transmittance of opaque building envelope structures. The technique was exploited to measure wall thermal transmittance of different buildings located in the city of Reggio Calabria (Italy),
引用
收藏
页数:5
相关论文
共 17 条
[1]  
Aberge LT, 2018, GLOBAL STATUS REPORT
[2]   Balancing the impacts of energy efficiency strategies on comfort quality of interior places: Application of optimization algorithms in domestic housing [J].
Aghamolaei, Reihaneh ;
Ghaani, Mohammad Reza .
JOURNAL OF BUILDING ENGINEERING, 2020, 29 (29)
[3]  
Ahmed Somaya Albadry, 2019, IOP Conference Series: Earth and Environmental Science, V397, DOI 10.1088/1755-1315/397/1/012021
[4]  
[Anonymous], 1999, 8990 UNI EN ISO
[5]  
[Anonymous], 2015, UNI ISO 9869-1
[6]  
Branchi D., 2009, MEAUREMENT U VALUE T
[7]   Effect of different parameters on the in situ thermal conductance evaluation [J].
Cesaratto, Pier Giorgio ;
De Carli, Michele ;
Marinetti, Sergio .
ENERGY AND BUILDINGS, 2011, 43 (07) :1792-1801
[8]   Analysis of Convergence Characteristics of Average Method Regulated by ISO 9869-1 for Evaluating In Situ Thermal Resistance and Thermal Transmittance of Opaque Exterior Walls [J].
Choi, Doo Sung ;
Ko, Myeong Jin .
ENERGIES, 2019, 12 (10)
[9]  
DallO G., 2020, BUILDINGS ED, P317, DOI [10.1007/978-3- 030-33687-5_28, DOI 10.1007/978-3-030-33687-5_28]
[10]  
DellIsola M., 2009, 6 C METR QUAL