Perchlorate analysis using solid-phase extraction cartridges

被引:4
|
作者
Medina, VF
Larson, SL
Extine, B
Bednar, A
机构
[1] USA, Environm Lab, Engn Res & Dev Ctr, Vicksburg, MS USA
[2] Appl Res Associates Inc, So Div, Vicksburg, MS 39180 USA
关键词
D O I
10.1093/chromsci/43.4.195
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Perchlorate is a compound of increasing concern as an environmental contaminant and is being regulated at increasingly stringent levels. Reliable methods are needed to consistently analyze perchlorate at low concentration levels. This research investigates the use of solid-phase extraction cartridges as an alternative to large-volume injection loops to achieve low-level (μg/L level) perchlorate quantitation. The method involves commercially available strong anion exchange (SAX) cartridges. Water samples are filtered (100 to 1000 ml) using the cartridge, which removes the perchlorate from the solution by anion exchange. Then, after the desired volume is filtered, the perchlorate is extracted using 4 ml of 1 % NaOH. In addition, a cleanup method is developed to remove competing anions (chloride, sulfate, and carbonate) that are often found in environmental samples. Analyses are performed with an ion Chromatograph using a 10-μL injection loop, yielding a perchlorate method detection limit (MDL) of 210 μg/L. One-liter volumes of a 2-μg/L perchlorate spiked deionized water solution are filtered with SAX SPE. Following extraction and analysis, an MDL of 0.82 μg/L is obtained, comparable to that found for 1-mL injection loop systems (reported as low as 0.53 μg/L). MDL studies are then conducted on perchlorate-amended groundwater (solution concentration of 70 μg/L) and surface water (solution concentration of 10 μg/L) using a filtration volume of 200 ml. The MDLs are 6.7 μg/L for the groundwater and 2.4 μg/L for the surface water.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 50 条
  • [41] Solid-Phase Extraction
    不详
    LC GC NORTH AMERICA, 2013, 31 (01) : 74 - 74
  • [42] Evaluation of two new examples of graphitized carbon blacks for use in solid-phase extraction cartridges
    Crescenzi, C
    DiCorcia, A
    Passariello, G
    Samperi, R
    Carou, MIT
    JOURNAL OF CHROMATOGRAPHY A, 1996, 733 (1-2) : 41 - 55
  • [43] Stability of fluoroquinolone antibiotics in river water samples and in octadecyl silica solid-phase extraction cartridges
    Turiel, E
    Martín-Esteban, A
    Bordin, G
    Rodríguez, AR
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 380 (01) : 123 - 128
  • [44] Miniaturized 3D printed solid-phase extraction cartridges with integrated porous frits
    Ren, Xinpeng
    Balavandy, Sepideh Keshan
    Li, Feng
    Breadmore, Michael C.
    Maya, Fernando
    ANALYTICA CHIMICA ACTA, 2022, 1208
  • [45] Stability of fluoroquinolone antibiotics in river water samples and in octadecyl silica solid-phase extraction cartridges
    Esther Turiel
    Antonio Martín-Esteban
    Guy Bordin
    Adela R. Rodríguez
    Analytical and Bioanalytical Chemistry, 2004, 380 : 123 - 128
  • [46] SOLID-PHASE EXTRACTION BASICS FOR WATER ANALYSIS
    MARKELL, CG
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 13 - CEI
  • [47] Solid-phase extraction for oil and grease analysis
    Lau, SL
    Stenstrom, MK
    WATER ENVIRONMENT RESEARCH, 1997, 69 (03) : 368 - 374
  • [48] Fast copper speciation screenings with solid-phase extraction cartridges using high-specific activity 64 Cu
    J. van Doornmalen
    K. J. Kroon
    J. T. van Elteren
    J. J.M. de Goeij
    Journal of Radioanalytical and Nuclear Chemistry, 2001, 249 (2) : 349 - 353
  • [49] SOLID-PHASE EXTRACTION AND HPLC ANALYSIS OF BENZODIAZEPINES
    MAZHAR, M
    BINDER, SR
    MCEACHERN, MB
    CLINICAL CHEMISTRY, 1988, 34 (06) : 1263 - 1263
  • [50] IMPROVEMENT OF EXTRACTION AND CONCENTRATION OF MILK PEPTIDES WITH SOLID-PHASE CARTRIDGES FOR ANALYSIS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    VOIRIN, A
    LETAVERNIER, JF
    SEBILLE, B
    JOURNAL OF CHROMATOGRAPHY, 1991, 553 (1-2): : 155 - 164