Lens of the eye dose calculation for neuro-interventional procedures and CBCT scans of the head

被引:7
作者
Xiong, Zhenyu [1 ]
Vijayan, Sarath [1 ]
Rana, Vijay [1 ]
Jain, Amit [1 ]
Rudin, Stephen [1 ]
Bednarek, Daniel R. [1 ]
机构
[1] Univ Buffalo, Toshiba Stroke & Vasc Res Ctr, Buffalo, NY USA
来源
MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING | 2016年 / 9783卷
关键词
lens dose; Monte Carlo; EGSnrc; DTS; CBCT; neuro-interventional procedure; RADIATION;
D O I
10.1117/12.2216504
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The aim of this work is to develop a method to calculate lens dose for fluoroscopically-guided neuro-interventional procedures and for CBCT scans of the head. EGSnrc Monte Carlo software is used to determine the dose to the lens of the eye for the projection geometry and exposure parameters used in these procedures. This information is provided by a digital CAN bus on the Toshiba Infinix C-Arm system which is saved in a log file by the real-time skin-dose tracking system (DTS) we previously developed. The x-ray beam spectra on this machine were simulated using BEAMnrc. These spectra were compared to those determined by SpekCalc and validated through measured percent-depth-dose (PDD) curves and half-value-layer (HVL) measurements. We simulated CBCT procedures in DOSXYZnrc for a CTDI head phantom and compared the surface dose distribution with that measured with Gafchromic film, and also for an SK150 head phantom and compared the lens dose with that measured with an ionization chamber. Both methods demonstrated good agreement. Organ dose calculated for a simulated neuro-interventional-procedure using DOSXYZnrc with the Zubal CT voxel phantom agreed within 10% with that calculated by PCXMC code for most organs. To calculate the lens dose in a neuro-interventional procedure, we developed a library of normalized lens dose values for different projection angles and kVp's. The total lens dose is then calculated by summing the values over all beam projections and can be included on the DTS report at the end of the procedure.
引用
收藏
页数:15
相关论文
共 14 条
  • [1] Verification of the performance accuracy of a real-time skin-dose tracking system for interventional fluoroscopic procedures
    Bednarek, Daniel R.
    Barbarits, Jeffery
    Rana, Vijay K.
    Nagaraja, Srikanta P.
    Josan, Madhur S.
    Rudin, Stephen
    [J]. MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [2] Risk of cataract after exposure to low doses of ionizing radiation: A 20-year prospective cohort study among US radiologic technologists
    Chodick, Gabriel
    Bekiroglu, Nural
    Hauptmann, Michael
    Alexander, Bruce H.
    Freedman, D. Michal
    Doody, Michele Morin
    Cheung, Li C.
    Simon, Steven L.
    Weinstock, Robert M.
    Bouville, Andre
    Sigurdson, Alice J.
    [J]. AMERICAN JOURNAL OF EPIDEMIOLOGY, 2008, 168 (06) : 620 - 631
  • [3] Cucinotta FA, 2001, RADIAT RES, V156, P460, DOI 10.1667/0033-7587(2001)156[0460:SRACIA]2.0.CO
  • [4] 2
  • [5] ICRP, 2007, USITC PUBL, V103
  • [6] Kawrakow I., 2011, PIRS701 NAT RES COUN
  • [7] Kawrakow I., 2006, PIRS624 NRCC
  • [8] SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes
    Poludniowski, G.
    Landry, G.
    DeBlois, F.
    Evans, P. M.
    Verhaegen, F.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (19) : N433 - N438
  • [9] Rogers DWO, 2007, PIRS0509 NAT RES COU
  • [10] Tapiovaara M., 2008, PCXMC MONTE CARLO PR