Piezoelectric pumping in flow analysis: Application to the spectrophotometric determination of gabapentin

被引:27
作者
Ribeiro, Marta F. T. [1 ]
Santos, Joao L. M. [1 ]
Lima, Jose L. F. C. [1 ]
机构
[1] Univ Porto, REQUIMTE, Fac Farm, P-4099030 Oporto, Portugal
关键词
piezoelectric micro-pump; flow analysis; pulsed flow; gabapentin; 1,2-naphthoquinone-4-sulfonate; multi-pumping;
D O I
10.1016/j.aca.2006.11.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solutions propelling devices are fundamental components of a flow-based analytical manifold. in this work different manifold configurations were implemented to evaluate the performance of multiple piezoelectric micro-pumps used as solutions insertion and propulsion devices. The micro-pumps are piezo-actuated micro-diaphragm pumps with passive check valves characterised by a small compact size and low power demands, and are able to produce reproducible flow rates of up to 4mL min(-1). The flow rate is controlled by the frequency of the piezoelectric actuator (up to 20Hz). As an additional feature, piezoelectric micro-pumps actuation generates a pulsed flowing stream that ensures a faster sample/reagent mixing contributing to improved reaction development. The developed flow approach was assessed in the spectrophotometric determination of gabapentin in pharmaceutical preparations upon reaction with 1,2-naphthoquinone-4-sulfonate in alkaline medium. Distinct flow manifold configurations were designed for achievement of different solutions management. Linear calibrations plots for gabapentin concentrations of up to 150mgL(-1), with relative standard deviations of less than 1.50% (n = 10) and a sample throughput of about 28 determinations per hour, were obtained. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:14 / 20
页数:7
相关论文
共 21 条
[1]  
[Anonymous], STAT CHEMOMETRICS AN
[2]   Sequential injection system in flame atomic absorption spectrometry for the determination of calcium and magnesium in mineral waters [J].
Araújo, AN ;
Costa, RCC ;
Lima, JLFC ;
Reis, BF .
ANALYTICA CHIMICA ACTA, 1998, 358 (02) :111-119
[3]   Quantitative determination of vigabatrin and gabapentin in human serum by gas chromatography-mass spectrometry [J].
Borrey, DCR ;
Godderis, KO ;
Engelrelst, VIL ;
Bernard, DR ;
Langlois, MR .
CLINICA CHIMICA ACTA, 2005, 354 (1-2) :147-151
[4]   PULSED REAGENT INTRODUCTION THROUGH A MEMBRANE REACTOR FOR FLOW-INJECTION SYSTEMS [J].
DASGUPTA, PK ;
VITHANAGE, RS ;
PETERSEN, K .
ANALYTICA CHIMICA ACTA, 1988, 215 (1-2) :277-282
[5]   Flow analysis based on a pulsed flow of solution: theory, instrumentation and applications [J].
Francis, PS ;
Lewis, SW ;
Lim, KF ;
Carlsson, K ;
Karlberg, B .
TALANTA, 2002, 58 (06) :1029-1042
[6]  
GARCIA LL, 1995, J CHROMATOGR B, V669, P157
[7]   Gabapentin quantification in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Application to bioequivalence study [J].
Ifa, DR ;
Falci, M ;
Moraes, ME ;
Bezerra, FAF ;
Moraes, MO ;
de Nucci, G .
JOURNAL OF MASS SPECTROMETRY, 2001, 36 (02) :188-194
[8]   Rapid high-performance liquid chromatographic determination of serum gabapentin [J].
Jiang, QB ;
Li, SG .
JOURNAL OF CHROMATOGRAPHY B, 1999, 727 (1-2) :119-123
[9]   Photochemical-fluorimetric determination of folic acid in a multicommutated flow system [J].
Lapa, RAS ;
Lima, JLFC ;
Reis, BF ;
Santos, JLM ;
Zagatto, EAG .
ANALYTICA CHIMICA ACTA, 1997, 351 (1-3) :223-228
[10]   Multi-pumping in flow analysis: concepts, instrumentation, potentialities [J].
Lapa, RAS ;
Lima, JLFC ;
Reis, BF ;
Santos, JLM ;
Zagatto, EAG .
ANALYTICA CHIMICA ACTA, 2002, 466 (01) :125-132