T1 measurement using a short acquisition period for quantitative cardiac applications

被引:47
作者
Higgins, DM [1 ]
Ridgway, JP
Radjenovic, A
Sivananthan, UM
Smith, MA
机构
[1] Leeds Teaching Hosp NHS Trust, Dept Med Phys & Engn, Leeds, W Yorkshire, England
[2] Univ Leeds, Acad Unit Med Phys, Leeds, W Yorkshire, England
[3] Gen Infirm, Cardiac Magnet Resonance Unit, Leeds LS1 3EX, W Yorkshire, England
[4] Univ Teesside, Middlesbrough, Cleveland, England
关键词
magnetic resonance imaging; relaxation times; quantification; myocardial perfusion;
D O I
10.1118/1.1921668
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Myocardial signal intensity curves for myocardial perfusion studies may be made quantitative by the use of T1 measurements made after the first-pass of contrast agent. A short data acquisition method for T1 mapping is presented in which all data for each T1 map are acquired in a short breath hold, and the slice geometry and timing in the cardiac cycle exactly match that of the dynamic first-pass perfusion sequence. This allows accurate image registration of the T1 map with the first-pass series of images. The T1 method is based on varying the preparation-pulse delay time of a saturation recovery sequence, and in this implementation employs an ECG-triggered, single-shot, spoiled gradient echo technique with SENSE reconstruction. The method allows T1 estimates of three slices to be made in fifteen heartbeats. For a range of samples with T1 values equivalent to those found in the myocardium during the first-pass of contrast agent, T1 estimates were accurate to within 6%, and the variation between slices was 2% or less. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:1738 / 1746
页数:9
相关论文
共 48 条
  • [31] 2-S
  • [32] RADJENOVIC A, 2002, MAGN RESON MATER PHY, V15, P227
  • [33] T1 quantification with inversion recovery TrueFISP
    Scheffler, K
    Hennig, J
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) : 720 - 723
  • [34] Normal myocardial perfusion assessed with multishot echo-planar imaging
    Schwitter, J
    Debatin, JF
    vonSchulthess, GK
    McKinnon, GC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) : 140 - 147
  • [35] First-pass myocardial perfusion MR imaging with interleaved notched saturation: Feasibility study
    Slavin, GS
    Wolff, SD
    Gupta, SN
    Foo, TKF
    [J]. RADIOLOGY, 2001, 219 (01) : 258 - 263
  • [36] Stanisz GJ, 2000, MAGNET RESON MED, V44, P665, DOI 10.1002/1522-2594(200011)44:5<665::AID-MRM1>3.0.CO
  • [37] 2-M
  • [38] IMPROVED SIGNAL IN SNAPSHOT FLASH BY VARIABLE FLIP ANGLES
    STEHLING, MK
    [J]. MAGNETIC RESONANCE IMAGING, 1992, 10 (01) : 165 - 167
  • [39] TISSUE DISTRIBUTION AND MAGNETIC-RESONANCE SPIN-LATTICE RELAXATION EFFECTS OF GADOLINIUM-DTPA
    STRICH, G
    HAGAN, PL
    GERBER, KH
    SLUTSKY, RA
    [J]. RADIOLOGY, 1985, 154 (03) : 723 - 726
  • [40] A NOVEL FAST T1-MAPPING METHOD
    TONG, CY
    PRATO, FS
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05): : 701 - 708