T1 measurement using a short acquisition period for quantitative cardiac applications

被引:48
作者
Higgins, DM [1 ]
Ridgway, JP
Radjenovic, A
Sivananthan, UM
Smith, MA
机构
[1] Leeds Teaching Hosp NHS Trust, Dept Med Phys & Engn, Leeds, W Yorkshire, England
[2] Univ Leeds, Acad Unit Med Phys, Leeds, W Yorkshire, England
[3] Gen Infirm, Cardiac Magnet Resonance Unit, Leeds LS1 3EX, W Yorkshire, England
[4] Univ Teesside, Middlesbrough, Cleveland, England
关键词
magnetic resonance imaging; relaxation times; quantification; myocardial perfusion;
D O I
10.1118/1.1921668
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Myocardial signal intensity curves for myocardial perfusion studies may be made quantitative by the use of T1 measurements made after the first-pass of contrast agent. A short data acquisition method for T1 mapping is presented in which all data for each T1 map are acquired in a short breath hold, and the slice geometry and timing in the cardiac cycle exactly match that of the dynamic first-pass perfusion sequence. This allows accurate image registration of the T1 map with the first-pass series of images. The T1 method is based on varying the preparation-pulse delay time of a saturation recovery sequence, and in this implementation employs an ECG-triggered, single-shot, spoiled gradient echo technique with SENSE reconstruction. The method allows T1 estimates of three slices to be made in fifteen heartbeats. For a range of samples with T1 values equivalent to those found in the myocardium during the first-pass of contrast agent, T1 estimates were accurate to within 6%, and the variation between slices was 2% or less. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:1738 / 1746
页数:9
相关论文
共 48 条
[31]  
2-S
[32]  
RADJENOVIC A, 2002, MAGN RESON MATER PHY, V15, P227
[33]   T1 quantification with inversion recovery TrueFISP [J].
Scheffler, K ;
Hennig, J .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :720-723
[34]   Normal myocardial perfusion assessed with multishot echo-planar imaging [J].
Schwitter, J ;
Debatin, JF ;
vonSchulthess, GK ;
McKinnon, GC .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) :140-147
[35]   First-pass myocardial perfusion MR imaging with interleaved notched saturation: Feasibility study [J].
Slavin, GS ;
Wolff, SD ;
Gupta, SN ;
Foo, TKF .
RADIOLOGY, 2001, 219 (01) :258-263
[36]  
Stanisz GJ, 2000, MAGNET RESON MED, V44, P665, DOI 10.1002/1522-2594(200011)44:5<665::AID-MRM1>3.0.CO
[37]  
2-M
[38]   IMPROVED SIGNAL IN SNAPSHOT FLASH BY VARIABLE FLIP ANGLES [J].
STEHLING, MK .
MAGNETIC RESONANCE IMAGING, 1992, 10 (01) :165-167
[39]   TISSUE DISTRIBUTION AND MAGNETIC-RESONANCE SPIN-LATTICE RELAXATION EFFECTS OF GADOLINIUM-DTPA [J].
STRICH, G ;
HAGAN, PL ;
GERBER, KH ;
SLUTSKY, RA .
RADIOLOGY, 1985, 154 (03) :723-726
[40]   A NOVEL FAST T1-MAPPING METHOD [J].
TONG, CY ;
PRATO, FS .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05) :701-708