Thermodynamic study on thermal insulation schemes for liquid helium storage tank

被引:14
|
作者
Zhang, Caigong [1 ]
Li, Changjun [1 ,2 ]
Jia, Wenlong [1 ,2 ]
Pang, Yu [1 ]
机构
[1] Southwest Petr Univ, Petr Engn Sch, Chengdu 610500, Sichuan, Peoples R China
[2] Southwest Petr Univ, CNPC Key Lab Oil & Gas Storage & Transportat, Chengdu 610500, Peoples R China
基金
中国国家自然科学基金;
关键词
Liquid helium tank; Thermal insulation schemes; Thermodynamic model; Variable density configuration; Self-evaporation vapor cooled shield; DENSITY MULTILAYER INSULATION; VAPOR-COOLED SHIELD; COMPOSITE INSULATION; HEAT-TRANSFER; OPTIMIZATION; PERFORMANCE; HYDROGEN; SYSTEM; FOAM; STRATIFICATION;
D O I
10.1016/j.applthermaleng.2021.117185
中图分类号
O414.1 [热力学];
学科分类号
摘要
The temperature of liquid helium (LHe) is 4.2 K, high-performance thermal insulation schemes such as the variable density (VD) and self-evaporation vapor-cooled shield (VCS) are required for LHe tank. However, the working parameters of the VD and VCS in LHe tank have not been investigated. However, the related researches on liquid hydrogen tank neglected the heat transfer of the tank wall and the gap; The VD configuration may less than the optimal because the maximum number of spacers for each layer was pre-set artificially. Meanwhile, the recovery rate of sensible heat cannot be obtained by the existing model. In this work, these limitations are taken into account to establish the thermodynamic model of composite multilayer insulation (FMLI), VD and VCS, respectively. The results show that the correction coefficient of FMLI model is 0.1875; The layer densities of composite variable density MLI (FVD-MLI) with four segments are 3.31, 6.62, 13.23, and 19.98 layer/cm, with a 9.6% reduction in heat leakage compared to that of FMLI. The optimal position of the VCS in VCS-composited MLI (FMLI + VCS) and VCS-composited variable density MLI (FVD-MLI + VCS) is approximately 30% and 25% near the cold boundary respectively, and 36.2% and 40.7% reduction in heat leakage compared to that of FMLI and FVD-MLI respectively. The VD and VCS promote each other in improving thermal insulation performance, while the VCS plays a greater role than VD.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Effect of initial parameter on thermodynamic performance in a liquid oxygen tank with pressurized helium gas
    Liu, Zhan
    Cue, Jie
    Yan, Jia
    Zhou, Guoqing
    Li, Yanzhong
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2020, 26 (03) : 426 - 436
  • [22] Computational design of vapor-cooled shield structure for liquid hydrogen storage tank
    Zhu, Xian You
    Lee, Jung Hee
    Kim, Kyong-Hwan
    Lee, Seong Hyuk
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2024, 38 (03) : 1575 - 1583
  • [23] Thermal Performance Analysis of a Mounded Liquid Ethylene Storage Tank
    Xin, Biping
    Wen, Jian
    Zhou, Aimin
    Wang, Simin
    CHEMICAL ENGINEERING & TECHNOLOGY, 2024, 47 (02) : 275 - 282
  • [24] Thermal analysis of coupled vapor-cooling-shield insulation for liquid hydrogen-oxygen pair storage
    Jiang, Wenbing
    Zuo, Zhongqi
    Sun, Peijie
    Li, Peng
    Huang, Yonghua
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (12) : 8000 - 8014
  • [25] Transient-state modeling and thermodynamic analysis of self-pressurization liquid hydrogen tank considering effect of vacuum multi-layer insulation coupled with vapor-cooled shield
    Li, Ke
    Wen, Jian
    Xin, Biping
    Zhou, Aimin
    Wang, Simin
    ENERGY, 2024, 286
  • [26] Numerical Study on Heat Leakage, Thermal Stratification, and Self-Pressurization Characteristics in Liquid Helium Storage Tanks
    Xu, Jing
    Liu, Fa'an
    Zhang, Jianguo
    Li, Chao
    Liu, Qinghua
    Li, Changjun
    Jia, Wenlong
    Fu, Shixiong
    Li, Longjiang
    ENERGIES, 2024, 17 (24)
  • [27] Study on transient thermal performance of coupled vapor-cooled shield insulation for liquid hydrogen tank during the on-orbit period
    Liang, Jiajia
    Li, Cui
    Ma, Yuan
    Liu, Xin
    Zhang, Shaohua
    Zhou, Zhenjun
    Li, Yanzhong
    APPLIED THERMAL ENGINEERING, 2025, 266
  • [28] ESTIMATION OF THERMAL INSULATION PERFORMANCE IN MULTILAYER INSULATOR FOR LIQUID-HELIUM PIPE
    SHIBANUMA, K
    KURIYAMA, M
    SHIBATA, T
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1991, 33 (11): : 1083 - 1095
  • [29] CFD investigation on helium pressurization behaviors in liquid hydrogen tank
    Wang, Lei
    Ye, Shixuan
    Ma, Yuan
    Wang, Jiaojiao
    Li, Yanzhong
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (52) : 30792 - 30803
  • [30] Thermodynamic optimization of composite insulation system with cold shield for liquid hydrogen zero-boil-off storage
    Zheng, Jianpeng
    Chen, Liubiao
    Liu, Xuming
    Zhu, Honglai
    Zhou, Yuan
    Wang, Junjie
    RENEWABLE ENERGY, 2020, 147 : 824 - 832