Preliminary investigation of performance of thermoluminescent dosimeters for dose verification in brachytherapy

被引:1
|
作者
D'Avino, V. [1 ]
Scarica, M. [2 ]
Ametrano, G. [3 ]
La Verde, G. [1 ,4 ,5 ]
Manti, L. [1 ,5 ]
Muto, P. [3 ]
Pugliese, M. [1 ,5 ]
Arrichiello, C. [3 ]
机构
[1] Natl Inst Nucl Phys, Sect Naples, Naples, Italy
[2] Univ Naples Federico II, Dept Elect Engn & Informat Technol, Naples, Italy
[3] IRCCS, Fdn G Pascale, Ist Nazl Tumori, Radiotherapy Unit, Naples, Italy
[4] Univ Naples Federico II, Dept Pharm, Naples, Italy
[5] Univ Naples Federico II, Dept Phys E Pancini, Naples, Italy
来源
NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS | 2020年 / 43卷 / 06期
关键词
NONMELANOMA SKIN-CANCER; HDR BRACHYTHERAPY; AAPM; PHOTON; RECOMMENDATIONS; TOXICITY; PREDICTION; POSITION; UPDATE; CERVIX;
D O I
10.1393/ncc/i2020-20149-5
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Brachytherapy represents the treatment of choice for many cancerous lesions, including skin tumours. Purpose of the study was to investigate the performance of thermoluminescent dosimeters of type 100, (TLD-100), for dose verification in high dose-rate treatment with a radioactive source of iridium-192. A set of TLDs-100 was calibrated with a 250 kVp X-ray beam in the dose range 0-5 Gy. Through a head and neck phantom, TLDs were fixed on districts corresponding to volumes of interest, including the target volume and some critical structures, then a single fraction of brachytherapy treatment was delivered. The dose measurements provided by TLDs were compared with the planned ones and the results were discussed in the light of limitations affecting the current treatment planning systems and critical aspects relating to brachytherapy implementation that still occurred in clinical settings. The findings of the study allow us to conclude that TLDs-100 show a good performance in the radiation field investigated and the use of so small, cheap and practical dosimetry system is potentially an optimal strategy of improving and standardizing the quality assurance protocol in brachytherapy.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Personalized Superficial HDR Brachytherapy-Dosimetric Verification of Dose Distribution with Lead Shielding of Critical Organs in the Head and Neck Region
    Zwierzchowski, Grzegorz
    Bieleda, Grzegorz
    Szymbor, Agata
    Boehlke, Marek
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (09):
  • [42] Verification of High Dose Rate 192Ir Source Position During Brachytherapy Treatment Using Silicon Pixel Detectors
    Batic, Matej
    Burger, Janez
    Cindro, Vladimir
    Kramberger, Gregor
    Mandic, Igor
    Mikuz, Marko
    Studen, Andrej
    Zavrtanik, Marko
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (05) : 2250 - 2256
  • [43] Experience of using MOSFET detectors for dose verification measurements in an end-to-end 192Ir brachytherapy quality assurance system
    Persson, Maria
    Nilsson, Josef
    Tedgren, Asa Carlsson
    BRACHYTHERAPY, 2018, 17 (01) : 227 - 233
  • [44] High Dose Rate Brachytherapy in the Treatment of cervical cancer: preliminary experience with cobalt 60 Radionuclide source-A Prospective Study
    Ntekim, Atara
    Adenipekun, Adeniyi
    Akinlade, Bidemi
    Campbell, Oladapo
    CLINICAL MEDICINE INSIGHTS-ONCOLOGY, 2010, 4 : 89 - 94
  • [45] Technical note: High-dose and ultra-high dose rate (UHDR) evaluation of Al2O3:C optically stimulated luminescent dosimeter nanoDots and powdered LiF:Mg,Ti thermoluminescent dosimeters for radiation therapy applications
    Liu, Kevin
    Velasquez, Brett
    Schuler, Emil
    MEDICAL PHYSICS, 2024, 51 (03) : 2311 - 2319
  • [46] Dosimetric performance of a multipoint plastic scintillator dosimeter as a tool for real-time source tracking in high dose rate192Ir brachytherapy
    Rosales, Haydee M. Linares
    Archambault, Louis
    Beddar, Sam
    Beaulieu, Luc
    MEDICAL PHYSICS, 2020, 47 (09) : 4477 - 4490
  • [47] Dosimetric investigation of a new high dose rate 192Ir brachytherapy source, IRAsource, by Monte Carlo method
    Rostami, Atefeh
    Hoseini, Mahdi
    Ghorbani, Mahdi
    Knaup, Courtney
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (01) : 139 - 145
  • [48] Deployment and performance of model-based dose calculation algorithm in 192Ir shielded cylinder brachytherapy
    Tien, Christopher J.
    Chen, Zhe
    BRACHYTHERAPY, 2019, 18 (06) : 883 - 889
  • [49] High dose brachytherapy (real time) in patients with intermediate- or high-risk prostate cancer: Technical description and preliminary experience
    Prada Gómez P.J.
    De La Rua Calderón A.
    Fonseca I.R.
    Suárez M.E.
    García J.M.A.
    Rijo G.J.
    García J.F.
    Sancho J.M.G.
    García R.A.
    Rodríguez-Fernández R.
    Clinical and Translational Oncology, 2005, 7 (9) : 389 - 397
  • [50] Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part II. High dose rate 192Ir sources
    Fulkerson, Regina K.
    Micka, John A.
    DeWerd, Larry A.
    MEDICAL PHYSICS, 2014, 41 (02)