Preliminary investigation of performance of thermoluminescent dosimeters for dose verification in brachytherapy

被引:1
|
作者
D'Avino, V. [1 ]
Scarica, M. [2 ]
Ametrano, G. [3 ]
La Verde, G. [1 ,4 ,5 ]
Manti, L. [1 ,5 ]
Muto, P. [3 ]
Pugliese, M. [1 ,5 ]
Arrichiello, C. [3 ]
机构
[1] Natl Inst Nucl Phys, Sect Naples, Naples, Italy
[2] Univ Naples Federico II, Dept Elect Engn & Informat Technol, Naples, Italy
[3] IRCCS, Fdn G Pascale, Ist Nazl Tumori, Radiotherapy Unit, Naples, Italy
[4] Univ Naples Federico II, Dept Pharm, Naples, Italy
[5] Univ Naples Federico II, Dept Phys E Pancini, Naples, Italy
来源
NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS | 2020年 / 43卷 / 06期
关键词
NONMELANOMA SKIN-CANCER; HDR BRACHYTHERAPY; AAPM; PHOTON; RECOMMENDATIONS; TOXICITY; PREDICTION; POSITION; UPDATE; CERVIX;
D O I
10.1393/ncc/i2020-20149-5
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Brachytherapy represents the treatment of choice for many cancerous lesions, including skin tumours. Purpose of the study was to investigate the performance of thermoluminescent dosimeters of type 100, (TLD-100), for dose verification in high dose-rate treatment with a radioactive source of iridium-192. A set of TLDs-100 was calibrated with a 250 kVp X-ray beam in the dose range 0-5 Gy. Through a head and neck phantom, TLDs were fixed on districts corresponding to volumes of interest, including the target volume and some critical structures, then a single fraction of brachytherapy treatment was delivered. The dose measurements provided by TLDs were compared with the planned ones and the results were discussed in the light of limitations affecting the current treatment planning systems and critical aspects relating to brachytherapy implementation that still occurred in clinical settings. The findings of the study allow us to conclude that TLDs-100 show a good performance in the radiation field investigated and the use of so small, cheap and practical dosimetry system is potentially an optimal strategy of improving and standardizing the quality assurance protocol in brachytherapy.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Development of Volumetric Independent Dose Calculation System for Verification of the Treatment Plan in Image-Guided Adaptive Brachytherapy
    Kang, Sang-Won
    Chung, Jin-Beom
    Kim, Kyeong-Hyeon
    Park, Ji-Yeon
    Park, Hae-Jin
    Cho, Woong
    Olberg, Sven
    Suh, Tae Suk
    Park, Justin C.
    FRONTIERS IN ONCOLOGY, 2020, 10
  • [32] Focal high-dose-rate brachytherapy for localized prostate cancer: toxicity and preliminary biochemical results
    Prada, Pedro J.
    Cardenal, Juan
    Garcia Blanco, Ana
    Andreescu, Jon
    Ferri, Maria
    Anchuelo, Javier
    Diaz de Cerio, Ivan
    Sierrasesumaga, Nicolas
    Vazquez, Andres
    Pacheco, Maite
    Ruiz Arrebola, Samuel
    STRAHLENTHERAPIE UND ONKOLOGIE, 2020, 196 (03) : 222 - 228
  • [33] Vaginal dose-surface maps in cervical cancer brachytherapy: Methodology and preliminary results on correlation with morbidity
    Serban, Monica
    de Leeuw, Astrid A. C.
    Tanderup, Kari
    Jurgenliemk-Schulz, Ina M.
    BRACHYTHERAPY, 2021, 20 (03) : 565 - 575
  • [34] Preliminary investigation of the safe dose of oleandrin when administered orally to Beagles
    Fossum, Theresa W.
    Newman, Robert A.
    Matos, Jose R.
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2024, 262 (07): : 966 - 972
  • [35] Preliminary investigation into the use of Raman spectroscopy for the verification of Australian grass and grain fed beef
    Logan, Bridgette G.
    Hopkins, David L.
    Schmidtke, Leigh
    Morris, Stephen
    Fowler, Stephanie M.
    MEAT SCIENCE, 2020, 160
  • [36] The American College of Radiology and the American Brachytherapy Society practice parameter for the performance of radionuclide-based high-dose-rate brachytherapy
    Erickson, Beth A.
    Bittner, Nathan H. J.
    Chadha, Manjeet
    Mourtada, Firas
    Demanes, D. Jeffrey
    BRACHYTHERAPY, 2017, 16 (01) : 75 - 84
  • [37] Preliminary results of MRI-assisted high-dose-rate interstitial brachytherapy for uterine cervical cancer
    Yoshida, Ken
    Yamazaki, Hideya
    Takenaka, Tadashi
    Kotsuma, Tadayuki
    Miyake, Shunsuke
    Ueda, Mari Mikami
    Yoshida, Mineo
    Masui, Koji
    Yoshioka, Yasuo
    Uesugi, Yasuo
    Shimbo, Taiju
    Yoshikawa, Nobuhiko
    Yoshioka, Hiroto
    Aramoto, Kazumasa
    Narumi, Yoshifumi
    Yamada, Shigetoshi
    Tatsumi, Keiji
    Tanaka, Eiichi
    BRACHYTHERAPY, 2015, 14 (01) : 1 - 8
  • [38] High-dose-rate interstitial brachytherapy in recurrent and previously irradiated head and neck cancers - Preliminary results
    Narayana, Ashwatha
    Cohen, Gil'ad N.
    Zaider, Marco
    Chan, Kelvin
    Lee, Nancy
    Wong, Richard J.
    Boyle, Jay
    Shaha, Ashok
    Kraus, Dennis
    Shah, Jatin
    Zelefsky, Michael J.
    BRACHYTHERAPY, 2007, 6 (02) : 157 - 163
  • [39] Preliminary Results of Concurrent Chemotherapy and Radiation Therapy using High-dose-rate Brachytherapy for Cervical Cancer
    Lee, Kyung-Ja
    Lee, Jihye
    Lee, Rena
    Suh, Hyunsuk
    RADIATION ONCOLOGY JOURNAL, 2006, 24 (03): : 171 - 178
  • [40] A Monte Carlo investigation of the dose distribution for new I-125 Low Dose Rate brachytherapy source in water and in different media
    Fardi, Zeinab
    Taherparvar, Payvand
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2019, 25 (01): : 15 - 22