Coupled-Inductor-Based DC Current Measurement Technique for Transformerless Grid-Tied Inverters

被引:32
作者
Abdelhakim, Ahmed [1 ]
Mattavelli, Paolo [1 ]
Yang, Dongsheng [2 ]
Blaabjerg, Frede [2 ]
机构
[1] Univ Padua, Dept Management & Engn, I-36100 Vicenza, Italy
[2] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
关键词
Coupled inductor; current sensor; current transformer; dc current; grid-tied inverters; photovoltaic; renewable energy sources; transformerless; voltage-source inverter (VSI); CONNECTED POWER CONVERTERS; CURRENT INJECTION; CONTROL STRATEGY; PV INVERTER; SYSTEMS; BIAS;
D O I
10.1109/TPEL.2017.2712197
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Grid-tied photovoltaic inverters must fulfill several requirements, including high efficiency and reduced cost and complexity of the overall system. Hence, transformerless operation is advantageous in order to achieve the prior requirements. Meanwhile, such operation results in several demerits, such as the dc current component injection into the grid. This component should be effectively mitigated in order to avoid some impacts, such as the saturation of the transformers in the distribution network. On the other hand, limiting this component up to few milliamperes is a challenging issue due to the various measurement errors. Accordingly, different blocking and measurement techniques have been proposed and studied to overcome this issue, where some demerits are seen behind each technique such as the implementation complexity, the common-mode voltage problems, and the high filter requirements. Moreover, none of them measures the dc component directly, but predicts its value using different approaches. Hence, this letter proposes a new technique to measure this dc current component with high accuracy using a coupled inductor combined with a small-range Hall effect current sensor in order to achieve the lowest possible cost with the highest possible accuracy. The proposed technique is introduced, analyzed, and tested experimentally to verify its principle of operation. Also experimental measurement of the dc current component using a 5-kVA transformerless grid-tied voltage-source inverter is introduced with and without the proposed technique in order to validate its operation.
引用
收藏
页码:18 / 23
页数:6
相关论文
共 29 条
[1]  
Abdelhakim A., 2017, IEEE T IND IN PRESS
[2]  
Ahfock T., 2006, P AUST U POW ENG C D, P1
[3]  
[Anonymous], 2014, REFERENCE TECHNICAL
[4]  
[Anonymous], 2003, IEEE Std 181-2003, DOI [10.1109/IEEESTD.2003.94394, DOI 10.1109/IEEESTD.2003.94285]
[5]  
[Anonymous], P IEEE INT WORKSH VI
[6]   Auto-calibrating dc link current sensing technique for transformerless, grid connected, H-bridge inverter systems [J].
Armstrong, Matthew ;
Atkinson, David. J. ;
Johnson, C. Mark ;
Abeyasekera, Tusitha. D. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2006, 21 (05) :1385-1393
[7]   Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Damping [J].
Bao, Chenlei ;
Ruan, Xinbo ;
Wang, Xuehua ;
Li, Weiwei ;
Pan, Donghua ;
Weng, Kailei .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) :1239-1253
[8]  
Berba F., 2012, 2012 2nd International Symposium on Environment-Friendly Energies and Applications (EFEA 2012), P296, DOI 10.1109/EFEA.2012.6294058
[9]  
Berba F., 2014, POW EL DISTR GEN SYS, P1
[10]  
Blaabjerg F., 2012, 2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG), P751, DOI 10.1109/PEDG.2012.6254086