Building legislation along with environmental and comfort concerns are increasingly driving designers of building services and air conditioning equipment towards more energy efficient solutions. Heat pipe technology is emerging as a viable, efficient and environmentally-sound technology for applications in efficient air handling unit designs. In this paper, an experimental investigation on the thermal performance of an air-to-air heat exchanger, which utilises heat pipe technology, will be presented. The heat exchanger consisted of 7 loop heat pipes with finned evaporator and condenser sections. The heat exchanger was fully instrumented to test for the effect of the variation of heat load and the air velocity, through the heat exchanger, on the overall thermal resistance of the loops. The values of the effectiveness of the heat pipe heat exchanger are shown to vary with the air velocity as expected but the results also allow the prediction of effectiveness variation with the heat load and operating temperature (previously assumed to be constant). The results allow an interpretation of the overall thermal performance of each loop heat pipe as a function of the load and air velocity. The paper concludes with a theoretical analysis of the energy savings that would be expected when utilising the technology in a representative application. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4592 / 4599
页数:8
相关论文
共 22 条
[1]   HEAT PIPE HEAT-STORAGE PERFORMANCE [J].
CARUSO, A ;
GRAKOVICH, LP ;
PASQUETTI, R ;
VASILIEV, LL .
HEAT RECOVERY SYSTEMS & CHP, 1989, 9 (05) :407-410
[2]  
CHEN K, ENERGY IN PRESS, DOI DOI 10.1016/J.ENERGY.2009.05.022
[3]  
Faghri Amir., 1995, HEAT PIPE SCI TECHNO
[4]  
HORBANIUC B, 2009, RENEW ENERG, V9, P605
[5]   Economic assessment of the benefits of wraparound heat pipes in ventilation processes for hot and humid climates [J].
Jouhara, Hussam .
INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2009, 4 (01) :52-60
[6]   Potential of heat pipe technology in nuclear seawater desalination [J].
Jouhara, Hussam ;
Anastasov, Vladimir ;
Khamis, Ibrahim .
DESALINATION, 2009, 249 (03) :1055-1061
[7]   Experimental investigation of small diameter two-phase closed thermosyphons charged with water, FC-84, FC-77 and FC-3283 [J].
Jouhara, Hussam ;
Robinson, Anthony J. .
APPLIED THERMAL ENGINEERING, 2010, 30 (2-3) :201-211
[8]   An Experimental Study of Small-Diameter Wickless Heat Pipes Operating in the Temperature Range 200°C to 450°C [J].
Jouhara, Hussam ;
Robinson, Anthony J. .
HEAT TRANSFER ENGINEERING, 2009, 30 (13) :1041-1048
[9]   Heat pipes as an extra measure to eliminate radioactive contamination in nuclear seawater desalination [J].
Khamis, Ibrahim ;
Jouhara, Hussam ;
Anastasov, Vladimir .
DESALINATION AND WATER TREATMENT, 2010, 13 (1-3) :82-87
[10]   An experimental study on the heat transfer characteristics of a heat pipe heat exchanger with latent heat storage. Part II: Simultaneous charging/discharging modes [J].
Liu, ZL ;
Wang, ZY ;
Ma, CF .
ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (7-8) :967-991