A collinear angle-resolved photoelectron spectrometer

被引:2
|
作者
Windelius, O. [1 ,3 ]
Aguilar, A. [2 ]
Bilodeau, R. C. [2 ,4 ]
Juarez, A. M. [5 ]
Rebolledo-Salgado, I. [5 ]
Pegg, D. J. [6 ]
Rohlen, J. [3 ]
Castel, T. [7 ]
Welander, J. [3 ]
Hanstorp, D. [3 ]
机构
[1] Chalmers Univ Technol, Dept Phys, SE-41296 Gothenburg, Sweden
[2] Lawrence Berkeley Natl Lab, Adv Light Source, Berkeley, CA 94720 USA
[3] Univ Gothenburg, Dept Phys, SE-41296 Gothenburg, Sweden
[4] Univ Connecticut, Dept Phys, Storrs, CT 06269 USA
[5] Univ Nacl Autonoma Mexico, Inst Ciencias Fis, POB 48-3, Cuernavaca 62251, Morelos, Mexico
[6] Univ Tennessee, Dept Phys, Knoxville, TN 37996 USA
[7] Ecole Natl Super Ingenieurs Caen, ENSICAEN, 6 Blvd Marechal Juin, F-14050 Caen, France
基金
瑞典研究理事会;
关键词
Photoelectron spectroscopy; Photodetachment; Photoionization; Angular distributions; Synchrotron radiation; ANGULAR-DISTRIBUTIONS; NEGATIVE-ION; PHOTODETACHMENT; PHOTOIONIZATION; EXCITATION;
D O I
10.1016/j.nimb.2017.08.028
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In the present paper we describe a newly designed collinear photoelectron spectrometer for angular distribution measurements. We will henceforth refer to this instrument by the acronym PEARLS (PhotoElectron Angle-Resolved Linear Spectrometer). The design was motivated by the desire to collect electrons emitted from an extended linear source consisting of collinear photon and ion beams at a synchrotron radiation site. The electrons could be produced in either photoionization or photodetachment events. The primary advantage of a collinear beams geometry is that the effective interaction volume can be made much larger than that obtainable with a crossed beams geometry, which has been used in many earlier photoelectron spectroscopic studies. The present apparatus is capable of collecting electrons over a beam source length of 22 cm. The electrons are detected using Channel Electron Multipliers (CEMs). There are 4 detector planes placed perpendicular to the direction of the beam source, where each plane contains 4 CEMs. The use of all 4 detector planes with a total of 16 CEMs enhances the photoelectron signal, which is important at a synchrotron radiation site where the photon flux is typically low. If photoelectrons of different energies are emitted, the design allows for electrostatic energy analyzers to be placed in front of the CEMs. We have performed a photodetachment experiment to demonstrate the functionality of the PEARLS apparatus using a pulsed laser as the photon source. In particular, we have measured the angular distribution of photoelectrons ejected from Ag- at two different photon energies. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:144 / 152
页数:9
相关论文
共 50 条
  • [31] Development of a conical energy analyzer for angle-resolved photoelectron spectroscopy
    Iwasaki, K
    Mitsuke, K
    SURFACE REVIEW AND LETTERS, 2002, 9 (01) : 583 - 586
  • [32] ANGLE-RESOLVED X-RAY PHOTOELECTRON-SPECTROSCOPY
    FADLEY, CS
    PROGRESS IN SURFACE SCIENCE, 1984, 16 (03) : 275 - 388
  • [33] Angle-resolved secondary photoelectron emission from graphene interfaces
    Vilkov, Oleg Yu.
    Krasovskii, Eugene E.
    Fedorov, Alexander V.
    Rybkin, Artem G.
    Shikin, Alexander M.
    Laubschat, Clemens
    Budagosky, Jorge
    Vyalikh, Denis V.
    Usachov, Dmitry Yu.
    PHYSICAL REVIEW B, 2019, 99 (19)
  • [34] Angle-Resolved Photoelectron Spectroscopy for Studying the Electronic Structure of Nanosystems
    Usachov, Dmitry
    2014 TENTH INTERNATIONAL VACUUM ELECTRON SOURCES CONFERENCE (IVESC), 2014,
  • [35] TEARES: a toroidal energy- and angle-resolved electron spectrometer
    Siggel-King, MRF
    Lindsay, R
    Quinn, FM
    Pearson, J
    Fraser, G
    Thornton, G
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2004, 137 : 721 - 729
  • [36] A NEW MULTIDETECTION SPECTROMETER FOR STUDIES OF ANGLE-RESOLVED ELECTRON DISTRIBUTIONS
    ROY, D
    TREMBLAY, D
    TREMBLAY, B
    DUBE, D
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1990, 52 : 787 - 796
  • [37] Alternative detection for angle-resolved photoemission spectrometer in ultraviolet range
    Thomas, J
    Pollini, I
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (02): : 345 - 349
  • [38] ANGLE-RESOLVED AND SPIN-RESOLVED PHOTOELECTRON-SPECTROSCOPY IN ROTATIONALLY RESOLVED PHOTOIONIZATION OF HI
    MANK, A
    DRESCHER, M
    BROCKHINKE, A
    BOWERING, N
    HEINZMANN, U
    ZEITSCHRIFT FUR PHYSIK D-ATOMS MOLECULES AND CLUSTERS, 1994, 29 (04): : 275 - 289
  • [39] ENERGY-RESOLVED AND ANGLE-RESOLVED PHOTOELECTRON-SPECTROSCOPY OF NEGATIVE-IONS
    PEGG, DJ
    THOMPSON, JS
    COMPTON, RN
    ALTON, GD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 40-1 : 221 - 224
  • [40] Large solid-angle analyzer applied to angle-resolved ultraviolet photoelectron spectroscopy
    Sakai, Daisuke
    Miura, Daisuke
    Maruyama, Akira
    Ishikawa, Tsuyoshi
    Oshima, Chuhei
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2007, 159 (1-3) : 39 - 45