A review of recent trends in electrospray ionisation-mass spectrometry for the analysis of metal-organic ligand complexes

被引:95
作者
Keith-Roach, Miranda J. [1 ,2 ]
机构
[1] Univ Plymouth, Biogeochem Res Ctr, Plymouth PL4 8AA, Devon, England
[2] Univ Plymouth, Consolidated Radioisotope Facil CORiF, Sch Earth Ocean & Environm Sci, Plymouth PL4 8AA, Devon, England
关键词
Electrospray ionisation-mass spectrometry; Chromatography; Quantitation; pH; Oxidation state; Competition; Displacement; ANION-EXCHANGE CHROMATOGRAPHY; PROTEIN LIQUID-CHROMATOGRAPHY; ESI-MS; ICP-MS; CAPILLARY-ELECTROPHORESIS; SPECIATION ANALYSIS; ARABIDOPSIS-THALIANA; SOLUTION EQUILIBRIA; ION CHROMATOGRAPHY; AQUEOUS-SOLUTIONS;
D O I
10.1016/j.aca.2010.08.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrospray ionisation-mass spectrometry (ESI-MS) is used in a wide variety of fields to examine the formation, stoichiometry and speciation of complexes involving metals and organic ligands This article reviews the literature in this area over the past 5 years, examining trends in ESI-MS use and novel applications that enhance the scope of the technique ESI-MS can provide direct information on changes in speciation with metal ligand ratio and pH, identify metal oxidation state directly and allow insight into competitive interactions in ternary systems However, both the instrumental set-up and artefacts in the electrospraying process can affect the species distribution observed, and changes in solution chemistry can affect the relative ion intensity of species. Therefore, ESI-MS data is at its most powerful when corroborated by data from other experimental techniques, such as pH potentiometry The challenges in interpreting direct ESI-MS data quantitatively are discussed in detail, with reference to differences in the ion intensities of species, signal suppression and quantifying species distributions. The use of HPLC-ESI-MS is also reviewed, highlighting challenges and applications Overall, the need for more standard reporting of quality assurance data is discussed, to strengthen the applications of ESI-MS to metal-organic ligand complexes further (C) 2010 Elsevier B V All rights reserved
引用
收藏
页码:140 / 148
页数:9
相关论文
共 69 条
[1]   ELECTROSPRAY MASS-SPECTROMETRY AS A TECHNIQUE FOR ELEMENTAL ANALYSIS - PRELIMINARY-RESULTS [J].
AGNES, GR ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1992, 46 (03) :401-406
[2]   Affinity gradients drive copper to cellular destinations [J].
Banci, Lucia ;
Bertini, Ivano ;
Ciofi-Baffoni, Simone ;
Kozyreva, Tatiana ;
Zovo, Kairit ;
Palumaa, Peep .
NATURE, 2010, 465 (7298) :645-U145
[3]   Investigation of low molecular weight Al complexes in human serum by fast protein liquid chromatography (FPLC)-ETAAS and electrospray (ES)-MS-MS techniques [J].
Bantan, T ;
Milacic, R ;
Mitrovic, B ;
Pihlar, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (11) :1743-1748
[4]   The use of fast protein liquid chromatography with ICP-OES and ES-MS-MS detection for the determination of various forms of aluminium in the roots of Chinese cabbage [J].
Bantan-Polak, T ;
Mitrovic, B ;
Milacic, P .
ANALYTICA CHIMICA ACTA, 2005, 540 (01) :83-89
[5]   Stability of arsenic peptides in plant extracts: off-line versus on-line parallel elemental and molecular mass spectrometric detection for liquid chromatographic separation [J].
Bluemlein, Katharina ;
Raab, Andrea ;
Feldmann, Jorg .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (01) :357-366
[6]   Can we trust mass spectrometry for determination of arsenic peptides in plants:: comparison of LC-ICP-MS and LC-ES-MS/ICP-MS with XANES/EXAFS in analysis of Thunbergia alata [J].
Bluemlein, Katharina ;
Raab, Andrea ;
Meharg, Andrew A. ;
Charnock, John M. ;
Feldmann, Jorg .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (07) :1739-1751
[7]   Cobalt speciation study in the cobalt-cysteine system by electrospray ionization mass spectrometry and anion-exchange chromatography inductively coupled plasma atomic emission spectrometry [J].
Bresson, C ;
Colin, C ;
Chartier, F ;
Moulin, C .
APPLIED SPECTROSCOPY, 2005, 59 (05) :696-705
[8]   Preliminary speciation study of Co(II)-citrate system by ion pairing-reversed phase chromatography coupled to UV detector [J].
Bresson, C ;
Bion, L ;
Moulin, C ;
Lamouroux, C .
RADIOCHIMICA ACTA, 2005, 93 (11) :675-682
[9]   Study of metal complexes of a tripodal hydroxypyridinone ligand by electrospray tandem mass spectrometry [J].
Budimir, N ;
Fournier, F ;
Bailly, T ;
Burgada, R ;
Tabet, JC .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (13) :1822-1828
[10]   Characterisation of thorium-ethylenediaminetetraacetic acid and thorium-nitrilotriacetic acid species by electrospray ionisation-mass spectrometry [J].
Cartwright, Andrew J. ;
May, Colin C. ;
Worsfold, Paul J. ;
Keith-Roach, Miranda J. .
ANALYTICA CHIMICA ACTA, 2007, 590 (01) :125-131