Development of a tandem time-of-flight mass spectrometer with an electrospray ionization ion source

被引:6
作者
Nagao, Hirofumi [1 ]
Shimma, Shuichi [2 ]
Hayakawa, Shigeo [3 ]
Awazu, Kunio [4 ]
Toyoda, Michisato [1 ,2 ,5 ]
机构
[1] Osaka Univ, Renovat Ctr Instruments Sci Educ & Technol, Osaka 5600043, Japan
[2] Osaka Univ, Venture Business Lab, Ctr Adv Sci & Innovat, Suita, Osaka 5650871, Japan
[3] Osaka Prefecture Univ, Dept Chem, Grad Sch Sci, Naka Ku, Osaka 5998531, Japan
[4] Osaka Univ, Div Sustainable Energy & Environm Engn, Grad Sch Engn, Suita, Osaka 5650871, Japan
[5] Osaka Univ, Dept Phys, Grad Sch Sci, Osaka 5600043, Japan
来源
JOURNAL OF MASS SPECTROMETRY | 2010年 / 45卷 / 08期
关键词
tandem time-of-flight mass spectrometer; ESI-TOF/quadTOF; multiply protonated peptide; high-energy CID; quadratic-field ion mirror; COLLISION-INDUCED DISSOCIATION; SEQUENCE IONS; CHARGE-STATE; PEPTIDES; PROTEINS; FRAGMENTATION; SPECTRA; PROTEOMICS; TOF/TOF; LIFT;
D O I
10.1002/jms.1787
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new tandem time-of-flight mass spectrometer with an electrospray ionization ion source 'ESI-TOF/quadTOF' was designed and constructed to achieve the desired aim of structural elucidation via high-energy collision-induced dissociation (CID), and the simultaneous detection of all fragment ions. The instrument consists of an orthogonal acceleration-type ESI ion source, a linear TOF mass spectrometer, a collision cell, a quadratic-field ion mirror and a microchannel plate detector. High-energy CID spectra of doubly protonated angiotensin II and bradykinin were obtained. Several fragment ions such as a-, d-, v- and w-type ions, characteristic of high-energy CID, were clearly observed in these spectra. These high-energy CID fragment ions enabled confirmation of the complete sequence, including leucine-isoleucine determinations. It was demonstrated that high-energy CID of multiply protonated peptides could be achieved in the ESI-TOF/quadTOF. Copyright (c) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:937 / 943
页数:7
相关论文
共 50 条
[21]   Comparison of electrospray and matrix-assisted laser desorption ionization on the same hybrid quadrupole time-of-flight tandem mass spectrometer Application to bidimensional liquid chromatography of proteins from bovine milk fraction [J].
Molle, Daniel ;
Jardin, Julien ;
Piot, Michel ;
Pasco, Maryvonne ;
Leonil, Joelle ;
Gagnaire, Valerie .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (12) :2424-2432
[22]   Development of an ion trap/multi-turn time-of-flight mass spectrometer with potential-lift [J].
Iwamoto, Kenichi ;
Nagao, Hirofumi ;
Toyoda, Michisato .
EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2009, 15 (02) :249-260
[23]   Using a matrix-assisted laser desorption ionization time-of-flight mass spectrometer for combined in-source decay/post-source decay experiments [J].
Pfeifer, T ;
Drewello, M ;
Schierhorn, A .
JOURNAL OF MASS SPECTROMETRY, 1999, 34 (06) :644-650
[24]   A collinear tandem time-of-flight mass spectrometer for infrared photodissociation spectroscopy of mass-selected ions [J].
Wang GuanJun ;
Chi ChaoXian ;
Xing XiaoPeng ;
Ding ChuanFan ;
Zhou MingFei .
SCIENCE CHINA-CHEMISTRY, 2014, 57 (01) :172-177
[25]   Structural characterization and identification of major constituents in Radix Scrophulariae by HPLC coupled with electrospray ionization quadrupole time-of-flight tandem mass spectrometry [J].
Chen You-Hua ;
Qi Jin ;
Hua Jing ;
Yu Bo-Yang .
CHINESE JOURNAL OF NATURAL MEDICINES, 2014, 12 (01) :47-54
[26]   Capillary electrophoresis and off-line capillary electrophoresis-electrospray ionization quadrupole time-of-flight tandem mass spectrometry of carbohydrates [J].
Zamfir, A ;
König, S ;
Althoff, J ;
Peter-Katalinc, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 895 (1-2) :291-299
[27]   Nitroimidazolic radiosensitizers investigated by electrospray ionization time-of-flight mass spectrometry and density functional theory [J].
Pandeti, S. ;
Feketeova, L. ;
Reddy, T. J. ;
Abdoul-Carime, H. ;
Farizon, B. ;
Farizon, M. ;
Mark, T. D. .
RSC ADVANCES, 2017, 7 (71) :45211-45221
[28]   Comparison of the Internal Energy Deposition of Direct Analysis in Real Time and Electrospray Ionization Time-of-Flight Mass Spectrometry [J].
Harris, Glenn A. ;
Hostetler, Dana M. ;
Hampton, Christina Y. ;
Fernandez, Facundo M. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2010, 21 (05) :855-863
[29]   Characterization of Bacitracin Zinc by Matrix-Assisted Laser Desorption Ionization - Tandem Time-of-Flight Mass Spectrometry [J].
Zhao, Wen-jie ;
Qiao, Jun-qin ;
Song, Qun ;
Lian, Hong-zhen .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 2015, 43 (04) :453-468
[30]   Characterization and identification of steroidal alkaloids in Fritillaria species using liquid chromatography coupled with electrospray ionization quadrupole time-of-flight tandem mass spectrometry [J].
Zhou, Jian-Liang ;
Xin, Gui-Zhong ;
Shi, Zi-Qi ;
Ren, Mei-Ting ;
Qi, Lian-Wen ;
Li, Hui-Jun ;
Li, Ping .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (45) :7109-7122