Real-time monitoring of cardiac regional function using FastHARP MRI and region-of-interest reconstruction

被引:9
作者
Abd-Elmoniem, Khaled Z. [1 ]
Sampath, Smita
Osman, Nael F.
Prince, Jerry L.
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
[2] NHLBI, Cardiac Energet Lab, NIH, Bethesda, MD 20892 USA
[3] Johns Hopkins Univ, Dept Elect & Comp Engn, Image Anal & Commun Lab, Baltimore, MD 21218 USA
[4] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21205 USA
关键词
cardiac motion; FastHARP (HARP-MRI); harmonic phase (HARP); magnetic resonance (MR) tagging; myocardial strain; real-time imaging;
D O I
10.1109/TBME.2007.891946
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cardiovascular stress test imaging assists in the diagnosis and monitoring of cardiovascular disease. The procedure can be carried out in a magnetic resonance (MR) scanner using pharmacological agents that mimic the effects of natural exercise. In order to provide real time indication of ischemia, thereby assisting in diagnosis and helping to assure patient safety, it is desirable to have real time monitoring of the myocardial regional function. This paper presents an algorithm for the real time myocardium region-of-interest reconstruction and myocardial strain computation using data acquired from a real time pulse sequence that has been previously reported. The chirp Fourier transform is used for efficient computation, enabling a real-time continuous strain map at a rate of 25 frames/s. Coupled with a real time data path from the scanner to a laptop computer, this algorithm enables real time continuous monitoring of cardiac strain and is targeted for use in the early detection and quantification of ischemia during MR stress tests.
引用
收藏
页码:1650 / 1656
页数:7
相关论文
共 15 条
[1]  
ABDELMONIEM KZ, 2003, P MICCAI 6 INT C, P516
[2]  
ABDELMONIEM KZ, 2003, P SPIE MED IM C, P581
[3]  
ABDELMONIEM KZ, 2003, P INT SOC MAGN RES M, P89
[4]   HEART WALL MOTION - IMPROVED METHOD OF SPATIAL MODULATION OF MAGNETIZATION FOR MR IMAGING [J].
AXEL, L ;
DOUGHERTY, L .
RADIOLOGY, 1989, 172 (02) :349-350
[5]  
FRIGO M, 1999, FFTW DISCRETE FOURIE
[6]   Quantitative ischemia detection during cardiac magnetic resonance stress testing by use of FastHARP [J].
Kraitchman, DL ;
Sampath, S ;
Castillo, E ;
Derbyshire, JA ;
Boston, RC ;
Bluemke, DA ;
Gerber, BL ;
Prince, JL ;
Osman, NF .
CIRCULATION, 2003, 107 (15) :2025-2030
[7]  
Oppenheim R. W., 1999, DISCRETE TIME SIGNAL
[8]  
Osman NF, 1999, MAGN RESON MED, V42, P1048, DOI 10.1002/(SICI)1522-2594(199912)42:6<1048::AID-MRM9>3.0.CO
[9]  
2-M
[10]   Regenerating MR tagged images using harmonic phase (HARP) methods [J].
Osman, NF ;
Prince, JL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (08) :1428-1433