Heat Transfer Characteristics of Oscillating Heat Pipe With Water and Ethanol as Working Fluids

被引:29
作者
Xian, Haizhen [1 ]
Yang, Yongping [1 ]
Liu, Dengying [2 ]
Du, Xiaoze [1 ]
机构
[1] N China Elect Power Univ, Beijing Key Lab Energy Safety & Clean Utilizat, Sch Energy & Power Engn, Beijing 102206, Peoples R China
[2] Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
来源
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME | 2010年 / 132卷 / 12期
基金
中国国家自然科学基金;
关键词
oscillating heat pipe; heat transfer characteristics; water; ethanol; TRANSFER ENHANCEMENT; VISUALIZATION; CEOHP; PART;
D O I
10.1115/1.4002366
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, experiments were conducted to achieve a better understanding of the oscillating heat pipe (OHP) operating behavior with water and ethanol as working fluid. The experimental results showed that there existed a necessary temperature difference between the evaporator and the condenser section to keep the heat pipe working. The maximum effective conductivity of the water OHP reached up to 259 kW/m K, while that of the ethanol OHP is of 111 kW/m K. Not all the OHPs are operated in the horizontal operation mode. The heat transfer performance of the ethanol OHP was obviously affected by the filling ratio and the inclination angle but the influence law is irregular The effect of the filling ratio and the inclination angle of the water OHP were smaller than that of the ethanol one. The heat transfer performance of the OHP was improved with increase of operating temperature. The startup characteristics of the OHP depended on the establishment of the integral oscillating process, which was determined by the operating factors. The startup temperature of the ethanol OHP varied from 40 degrees C to 50 degrees C and that of the water, OHP varied from 40 degrees C to 60 degrees C without considering the horizontal operating mode. The water OHP showed a better performance and more stable heat transfer characteristics than the ethanol OHP, which had no obvious advantages of the startup capability as well. [DOI: 10.1115/1.4002366]
引用
收藏
页数:6
相关论文
共 13 条
[1]  
Akachi H., 1996, PROC 5 INT HEAT PIPE, P208
[2]   Closed loop pulsating heat pipes - Part A: parametric experimental investigations [J].
Charoensawan, P ;
Khandekar, S ;
Groll, M ;
Terdtoon, P .
APPLIED THERMAL ENGINEERING, 2003, 23 (16) :2009-2020
[3]  
GI K, 1999, P 11 INT HEAT PIP C, P166
[4]   Investigations on the heat transport capability of a cryogenic oscillating heat pipe and its application in achieving ultra-fast cooling rates for cell vitrification cryopreservation [J].
Han, Xu ;
Ma, Hongbin ;
Jiao, Anjun ;
Critser, John K. .
CRYOBIOLOGY, 2008, 56 (03) :195-203
[5]   Analysis of pulsating heat pipe with capillary wick and varying channel diameter [J].
Holley, B ;
Faghri, A .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (13) :2635-2651
[6]   Closed loop pulsating heat pipes - Part B: visualization and semi-empirical modeling [J].
Khandekar, S ;
Charoensawan, P ;
Groll, M ;
Terdtoon, P .
APPLIED THERMAL ENGINEERING, 2003, 23 (16) :2021-2033
[7]   Effect of nanofluid on the heat transport capability in an oscillating heat pipe [J].
Ma, HB ;
Wilson, C ;
Borgmeyer, B ;
Park, K ;
Yu, Q ;
Choi, SUS ;
Tirumala, M .
APPLIED PHYSICS LETTERS, 2006, 88 (14)
[8]  
Miyazaki Y., 1996, P 5 INT HEAT PIP S M, P378
[9]   Experimental study of the performance of a solar collector by closed-end oscillating heat pipe (CEOHP) [J].
Rittidech, S. ;
Wannapakne, S. .
APPLIED THERMAL ENGINEERING, 2007, 27 (11-12) :1978-1985
[10]   Closed-ended oscillating heat-pipe (CEOHP) air-preheater for energy thrift in a dryer [J].
Rittidech, S ;
Dangeton, W ;
Soponronnarit, S .
APPLIED ENERGY, 2005, 81 (02) :198-208