APPLICATION OF HYDROCYCLONE AND UV RADIATION AS A BALLAST WATER TREATMENT METHOD

被引:0
|
作者
Kurtela, Zeljko [1 ]
Komadina, Pavao [2 ]
机构
[1] Univ Dubrovnik, Maritime Dept, HR-20000 Dubrovnik, Croatia
[2] Univ Rijeka, Fac Maritime Studies, HR-51000 Rijeka, Croatia
来源
PROMET-TRAFFIC & TRANSPORTATION | 2010年 / 22卷 / 03期
关键词
ballast water treatment; hydrocyclone; UV radiation; application of method; pilot plant; hydrodynamic forces;
D O I
暂无
中图分类号
U [交通运输];
学科分类号
08 ; 0823 ;
摘要
The ballast water exchange methods in open sea are, for the time being, the prevailing procedures accepted by shipowners. However, such methods do not guarantee full efficacy in elimination of allochthonous organisms. Besides, in some navigation zones, in particular in the closed seas, not even the criteria prescribed by international regulations can be fulfilled, i.e. the position of a ship exchanging ballast must be farther than 200Nm from the shore (alternatively 50Nm) at the sea depth exceeding 200m. Numerous research attempts on various treatment methods lead to the conclusion that there is still no scientific opinion on the final choice of methods for wide application on board. The treatment methods, such as hydrocyclone separation in the first stage and UV radiation in the second stage, stand a good chance for application on board. Advantages of such a combined method are in the very application of treatment that can be performed during all stages of ballast water treatment, i.e. loading ballast, voyage in ballast and discharging ballast. In closed seas and on shorter routes the operational advantages of hydrocyclone and UV radiation could be the prevailing factor for application. Within the research on the possible application of ballast water treatment by hydrocyclone and UV radiation, a pilot plant with hydrocyclone cluster and UV device was constructed. The research carried out on the pilot plant installed on board the m/v "Nase more" proved the effectiveness of such ballast water treatment method and offered a new approach in using hydrocyclone for the inactivation of organisms by hydrodynamic forces. This approach has largely increased the efficacy of the device and a new method for utilization of hydrocyclone in ballast water treatment on board has been discovered.
引用
收藏
页码:183 / 191
页数:9
相关论文
共 50 条
  • [21] Flocculation process for the treatment of ballast water application research process
    Li, Xiaoyan
    Chen, Yang
    Liu, Sha
    Zhou, Zhimin
    MECHANICAL AND ELECTRONICS ENGINEERING VI, 2014, 654 : 39 - 42
  • [22] Sonication of bacteria, phytoplankton and zooplankton: Application to treatment of ballast water
    Holm, Eric R.
    Stamper, David M.
    Brizzolara, Robert A.
    Barnes, Laurie
    Deamer, Nora
    Burkholder, JoAnn M.
    MARINE POLLUTION BULLETIN, 2008, 56 (06) : 1201 - 1208
  • [23] The Efficiency of Application of UV + VUV Radiation for Preventing Unicellular Invasions Transported with Ballast Waters of Ships
    Fokanov V.P.
    Gavrilova O.V.
    Fokanov A.V.
    Russian Journal of Biological Invasions, 2019, 10 (1) : 68 - 73
  • [24] UV-LEDs combined with persulfate salts as a method to inactivate microalgae in ballast water
    Rivas-Zaballos, Ignacio
    Romero-Martinez, Leonardo
    Moreno-Garrido, Ignacio
    Moreno-Andres, Javier
    Acevedo-Merino, Asuncion
    Nebot, Enrique
    JOURNAL OF WATER PROCESS ENGINEERING, 2023, 51
  • [25] Which ballast water treatment?
    Anon
    MER Marine Engineers Review, 2001, (MAY):
  • [26] OptiMar ballast systems: Practical solution for ballast water treatment
    HSB International, 2002, 51 (03): : 42 - 43
  • [27] Recolonization by heterotrophic bacteria after UV irradiation or ozonation of seawater; a simulation of ballast water treatment
    Hess-Erga, Ole-Kristian
    Blomvagnes-Bakke, Bente
    Vadstein, Olau
    WATER RESEARCH, 2010, 44 (18) : 5439 - 5449
  • [28] UV-based technologies for marine water disinfection and the application to ballast water: Does salinity interfere with disinfection processes?
    Moreno-Andres, Javier
    Romero-Martinez, Leonardo
    Acevedo-Merino, Asuncion
    Nebot, Enrique
    SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 581 : 144 - 152
  • [29] KPI (KEY PERFORMANCE INDICATORS) APPLICATION ON BALLAST WATER TREATMENT SYSTEM SELECTION
    Yonsel, Fatma
    Vural, Gulcin
    BRODOGRADNJA, 2017, 68 (03): : 67 - 84
  • [30] Analysis on Application Effectiveness of Ballast Water Treatment Based on Advanced Oxidation Processes
    Zhang X.
    Zhang Y.
    Tian Y.
    Zhang X.
    Zhang Z.
    Liu R.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (08): : 2681 - 2688