Telemedicine Improves Continuous Positive Airway Pressure Adherence in Stroke Patients with Obstructive Sleep Apnea in a Randomized Trial

被引:26
|
作者
Nilius, Georg [1 ,4 ]
Schroeder, Maik [1 ]
Domanski, Ulrike [2 ]
Tietze, Adam [2 ,5 ]
Schaefer, Thorsten [2 ,5 ]
Franke, Karl-Josef [3 ,4 ]
机构
[1] Evang Kliniken Essen Mitte, Essen, Germany
[2] Helios Klin Hagen Ambrock, Hagen, Germany
[3] Mark Kliniken GmbH, Ludenscheid, Germany
[4] Univ Witten Herdecke, Witten, Germany
[5] Ruhr Univ Bochum, Bochum, Germany
关键词
Stroke; Obstructive sleep apnea; Continuous positive airway pressure; Telemedicine; Monitoring; Adherence; CARDIOVASCULAR EVENTS; ISCHEMIC-STROKE; CPAP; THERAPY; IMPACT; PREVALENCE; PREDICTORS;
D O I
10.1159/000501656
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: The prevalence of obstructive sleep apnea (OSA) is very high in stroke patients, whereas the acceptance of positive airway pressure (PAP) therapy is low. Although telemedicine offers new options to increase acceptance, effective concepts and patient groups are not yet known. Objective: The aim of this study was to investigate the effect of a telemedicine concept consisting of telemonitoring and support when usage time drops. Methods: PAP naive stroke patients with apnea-hypopnea index (AHI) >15 were randomized in a prospective parallel design comparing home therapy with standard care (SC) as opposed to telemedicine care (TC) over a period of 6 months. The TC group received a standardized phone call to offer help and advice if the average weekly usage of PAP fell below 4 h/night. Results: Eighty patients were included, 5 were lost to follow-up, 75 (20 females, age: 57.0 +/- 9.9, body mass index: 30.9 +/- 6.0 kg/m(2), AHI: 39.4 +/- 18.6) were evaluated. While inpatient usage was similar in both groups, a significant difference was identified after 6 months of receiving home therapy (TC: 4.4 +/- 2.5 h, SC: 2.1 +/- 2.2 h; p < 0.000063). On average, 4.7 +/- 3.1 interventional phone calls were needed (173 calls in total, ranging from 0 to 10 calls per patient), primarily for the purpose of motivation (61.3%), mask problems (16.2%), nasopharyngeal complaints or humidification issues (11.2%), and technical questions (10.6%). Sleepiness (Epworth Sleepiness Scale [ESS]) differed significantly (TC: 3.7 + 3.2, SC: 6.1 + 4.1; p = 0.008), as well as systolic blood pressure, which was available in a subgroup of 55 patients (TC: 129.5 + 15.2 mm Hg, SC: 138.8 + 16.1 mm Hg; p = 0.034). Conclusion: A concept of telemonitoring and short telephone calls from the sleep lab raised PAP therapy adherence significantly in a group of stroke patients with moderate to severe OSA.
引用
收藏
页码:410 / 420
页数:11
相关论文
共 50 条
  • [21] A Randomized Controlled Trial of Continuous Positive Airway Pressure on Glucose Tolerance in Obese Patients with Obstructive Sleep Apnea
    Salord, Neus
    Maria Fortuna, Ana
    Monasterio, Carmen
    Gasa, Merce
    Perez, Antonio
    Bonsignore, Maria R.
    Vilarrasa, Nuria
    Maria Montserrat, Josep
    Mayos, Mercedes
    SLEEP, 2016, 39 (01) : 35 - 41
  • [22] Continuous Positive Airway Pressure Treatment and Adherence in Obstructive Sleep Apnea
    Matthews, Ellyn E.
    Aloia, Mark S.
    SLEEP MEDICINE CLINICS, 2009, 4 (04) : 473 - 485
  • [23] The effect of continuous positive airway pressure on spectral encephalogram characteristics in stroke patients with obstructive sleep apnea
    Alshaer, Hisham
    Pandya, Aditya
    Zivanovic, Igor
    Carvalho, Carolina Gonzaga
    Ryan, Clodagh M.
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2018, 249 : 62 - 68
  • [24] Management of Obstructive Sleep Apnea by Continuous Positive Airway Pressure
    Weaver, Terri E.
    Sawyer, Amy
    ORAL AND MAXILLOFACIAL SURGERY CLINICS OF NORTH AMERICA, 2009, 21 (04) : 403 - +
  • [25] Erectile dysfunction in obstructive sleep apnea patients: A randomized trial on the effects of Continuous Positive Airway Pressure (CPAP)
    Pascual, Merce
    de Batlle, Jordi
    Barbe, Ferran
    Castro-Grattoni, Anabel L.
    Auguet, Josep M.
    Pascual, Lydia
    Vila, Manel
    Cortijo, Anunciacion
    Sanchez-de-la-Torre, Manuel
    PLOS ONE, 2018, 13 (08):
  • [26] Preoperative adherence to continuous positive airway pressure among obstructive sleep apnea patients
    Deflandre, E.
    Degey, S.
    Bonhomme, V.
    Donneau, A. F.
    Poirrier, R.
    Brichant, J. F.
    Hans, P.
    MINERVA ANESTESIOLOGICA, 2015, 81 (09) : 960 - 967
  • [27] Acute effects of continuous positive airway pressure in patients with obstructive sleep apnea
    Han, Su-Hyun
    Lee, Sang-Ahm
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2020, 54 (01) : 26 - 31
  • [28] Association of continuous positive airway pressure adherence with complications in patients with type 2 diabetes and obstructive sleep apnea
    Sheth, Urmi
    Monson, Rebecca S.
    Prasad, Bharati
    Sahni, Ashima S.
    Matani, Sara
    Mercado, Tomas
    Smith, Maureen A.
    Carlucci, Melissa A.
    Danielson, Kirstie K.
    Reutrakul, Sirimon
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2021, 17 (08): : 1563 - 1569
  • [29] Influence of Continuous Positive Airway Pressure on Outcomes of Rehabilitation in Stroke Patients With Obstructive Sleep Apnea
    Ryan, Clodagh M.
    Bayley, Mark
    Green, Robin
    Murray, Brian J.
    Bradley, T. Douglas
    STROKE, 2011, 42 (04) : 1062 - 1067
  • [30] Continuous positive airway pressure and adherence in patients with different endotypes of obstructive sleep apnea
    Cheng, Wan-Ju
    Finnsson, Eysteinn
    Agustsson, Jon S.
    Sands, Scott A.
    Hang, Liang-Wen
    JOURNAL OF SLEEP RESEARCH, 2024, 33 (01)