Current sensor fault detection and reconfiguration for a Doubly Fed Induction Generator

被引:23
作者
Rothenhagen, Kai [1 ]
Fuchs, Friedrich W. [1 ]
机构
[1] Univ Kiel, Inst Power Elect & Elect Dr, D-24143 Kiel, Germany
来源
2007 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6 | 2007年
关键词
D O I
10.1109/PESC.2007.4342450
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Sensor fault detection and reconfiguration of the control loops of a Doubly-Fed Induction Generator is presented in this paper. The stator and rotor currents are measured as well as observed. During fault free operation, the measured signals are used for the voltage oriented control. In case of a current sensor fault, the faulty measurement is identified and the control is reconfigured using the observer output. Laboratory measurements prove this concept.
引用
收藏
页码:2732 / 2738
页数:7
相关论文
共 50 条
[11]   Model and Performance of Current Sensor Observers for a Doubly Fed Induction Generator [J].
Li, Hui ;
Yang, Chao ;
Hu, Yaogang ;
Zhao, Meng ;
Zhao, Bin ;
Chen, Zhe ;
Liu, Shengquan ;
Yang, Dong .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2014, 42 (10) :1048-1058
[12]   Advanced Sensor Fault Detection and Control Reconfiguration of Wind Power Plants using Doubly Fed Induction Generators [J].
Rothenhagen, Kai ;
Fuchs, Friedrich W. .
2008 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-10, 2008, :913-919
[13]   The simulation research on the characteristic of fault current of doubly-fed induction generator [J].
Han, Aoyang ;
Zhang, Zhe ;
Yin, Xianggen .
Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2009, 37 (09) :105-108
[14]   Sensor fault-tolerant control for a doubly fed induction generator in a smart grid [J].
Conchas, Robin F. ;
Sanchez, Edgar N. ;
Ricalde, Luis J. ;
Alvarez, Jesus G. ;
Alanis, Alma Y. .
ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2023, 117
[15]   Current sensor fault diagnosis for doubly-fed wind generator control system [J].
Zhang, Chang-Fan ;
Yan, Min ;
He, Jing ;
Luo, Cheng ;
Xiao, Yuan-Yuan .
Information Technology Journal, 2013, 12 (18) :4368-4373
[16]   Performance of Sensor and Sensorless Doubly Fed Induction Motor (DFIM) under the Current Sensor Fault [J].
Singh, Arunesh Kumar ;
Saxena, Abhinav .
PROCEEDINGS OF THE FIRST IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, INTELLIGENT CONTROL AND ENERGY SYSTEMS (ICPEICES 2016), 2016,
[17]   Combined Signal and Model-Based Sensor Fault Diagnosis for a Doubly Fed Induction Generator [J].
Boulkroune, Boulaid ;
Galvez-Carrillo, Manuel ;
Kinnaert, Michel .
IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2013, 21 (05) :1771-1783
[18]   Fault Current Contribution Analysis of Doubly Fed Induction Generator-Based Wind Turbines [J].
El-Naggar, Ahmed ;
Erlich, Istvan .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (03) :874-882
[19]   An improved fault current calculation method and protection scheme of Doubly-fed Induction Generator [J].
Yin, Jun .
ENERGY REPORTS, 2021, 7 :5168-5174
[20]   Short Circuit Current Calculation of Doubly Fed Induction Generator [J].
Mortezapour, V. ;
Lesani, H. ;
Abbaszadeh, A. .
2009 INTERNATIONAL CONFERENCE ON ELECTRIC POWER AND ENERGY CONVERSION SYSTEMS (EPECS 2009), 2009, :128-+