EEG Artifact Removal System for Depression Using a Hybrid Denoising Approach

被引:6
|
作者
Kaur, Chamandeep [1 ]
Singh, Preeti [1 ]
Sahni, Sukhtej [2 ]
机构
[1] Panjab Univ Chandigarh, Dept Elect & Commun Engn, Chandigarh, India
[2] Cheema Med Complex, Dept Psychiat, Mohali, India
关键词
EEG; Wavelets; Artifacts; Empirical Mode Decomposition (EMD); Depression; EMPIRICAL MODE DECOMPOSITION; OCULAR ARTIFACTS; PERFORMANCE; REDUCTION; DIAGNOSIS; SUPPRESSION; FILTER;
D O I
10.32598/bcn.2021.1388.2
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Introduction: Several computer-aided diagnosis systems for depression are suggested for use by clinicians to authorize the diagnosis. EEG may be used as an objective analysis tool for identifying depression in the initial stage to avoid it from reaching a severe and permanent state. However, artifact contamination reduces the accuracy in EEG signal processing systems. Methods: This work proposes a novel denoi sing method based on Empirical Mode Decomposition (EMD) (with Detrended Fluctuation Analysis (DFA) and wavelet packet transform. Initially, real EEG recordings corresponding to depression patients are decomposed into various mode functions by applying EMD. Then, DFA is used as the mode selection criteria. Further Wavelet Packets Decomposition (WPD)-based evaluation is applied to extract the cleaner signal. Results: Simulations were conducted on real EEG databases for depression to demonstrate the effects of the proposed techniques. To conclude the efficacy of the proposed technique, SNR and MAE were identified. The obtained results indicated improved signal-to-noise ratio and lower values of MAE for the combined EMD-DFA-WPD technique. Additionally, Random Forest and SVM (Support Vector Machine)-based classification revealed the improved accuracy of 98.51% and 98.10% for the proposed denoising technique. Whereas the accuracy of the EMD-DFA is 98.01% and 95.81% and EMD combined with DWT technique equaled 98.0% and 97.21% for the EMD-DFA technique for RF and SVM, respectively, compared to the proposed method. Furthermore, the classification performance for both classifiers was compared with and without denoising to highlight the effects of the proposed technique. Conclusion: Proposed denoising system results in better classification of depressed and healthy individuals resulting in a better diagnosing system. These results can be further analyzed using other approaches as a solution to the mode mixing problem of the EMD approach.
引用
收藏
页码:465 / 476
页数:12
相关论文
共 50 条
  • [41] ARTIFACT REMOVAL FROM EEG A COMPARISON OF TECHNIQUES
    Johal, Pawanpreet Kaur
    Jain, Neelu
    2016 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, AND OPTIMIZATION TECHNIQUES (ICEEOT), 2016, : 2088 - 2091
  • [42] Intelligent fuzzy system for automatic artifact detection and removal from EEG signals
    Agounad, Said
    Hamou, Soukaina
    Tarahi, Ousama
    Moufassih, Mustapha
    Islam, Md Kafiul
    JOURNAL OF KING SAUD UNIVERSITY-COMPUTER AND INFORMATION SCIENCES, 2022, 34 (10) : 9428 - 9441
  • [43] Ghost artifact removal using a parallel imaging approach
    Winkelmann, R
    Börnert, P
    Dössel, O
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (04) : 1002 - 1009
  • [44] Power Line and Ocular Artifact Denoising from EEG using Notch Filter and Wavelet Transform
    Tibdewal, Manish N.
    Mahadevappa, M.
    Ray, Ajoy Kumar
    Malokar, Monika
    Dey, Himanshu R.
    PROCEEDINGS OF THE 10TH INDIACOM - 2016 3RD INTERNATIONAL CONFERENCE ON COMPUTING FOR SUSTAINABLE GLOBAL DEVELOPMENT, 2016, : 1654 - 1659
  • [45] IC-U-Net: A U-Net-based Denoising Autoencoder Using Mixtures of Independent Components for Automatic EEG Artifact Removal
    Chuang, Chun-Hsiang
    Chang, Kong-Yi
    Huang, Chih-Sheng
    Jung, Tzyy-Ping
    NEUROIMAGE, 2022, 263
  • [46] Ballistocardiographic artifact removal from simultaneous EEG-fMRI using an optical motion-tracking system
    LeVan, Pierre
    Maclaren, Julian
    Herbst, Michael
    Sostheim, Rebecca
    Zaitsev, Maxim
    Hennig, Juergen
    NEUROIMAGE, 2013, 75 : 1 - 11
  • [47] Removal of the ballistocardiographic artifact from EEG-fMRI data: a canonical correlation approach
    Assecondi, Sara
    Hallez, Hans
    Staelens, Steven
    Bianchi, Anna M.
    Huiskamp, Geertjan M.
    Lemahieu, Ignace
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (06): : 1673 - 1689
  • [48] Denosieformer: A Transformer-Based Approach for Single-Channel EEG Artifact Removal
    Chen, Junfu
    Pi, Dechang
    Jiang, Xiaoyi
    Xu, Yue
    Chen, Yang
    Wang, Xixuan
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 16
  • [49] Automatic EEG Artifact Removal: A Weighted Support Vector Machine Approach With Error Correction
    Shao, Shi-Yun
    Shen, Kai-Quan
    Ong, Chong Jin
    Wilder-Smith, Einar P. V.
    Li, Xiao-Ping
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (02) : 336 - 344
  • [50] Removal Of EOG From EEG By Adaptive Filtering Without Using Artifact Reference
    Shahbakhti, Mohammad
    2013 ISSNIP BIOSIGNALS AND BIOROBOTICS CONFERENCE (BRC), 2013, : 244 - 247