Quantitative analysis of volatiles from solid matrices of vegetable origin by high concentration capacity headspace techniques: Determination of furan in roasted coffee

被引:59
作者
Bicchi, Carlo [1 ]
Ruosi, Manuela Rosanna [1 ]
Cagliero, Cecilia [1 ]
Cordero, Chiara [1 ]
Liberto, Erica [1 ]
Rubiolo, Patrizia [1 ]
Sgorbini, Barbara [1 ]
机构
[1] Dipartimento Sci & Tecnol Farmaco, Lab Phytochem Anal, I-10125 Turin, Italy
关键词
Furan; 2-Methyl-furan; Roasted coffee; HS-SPME-GC-MS; HS-SPME-MS; Quantitative analysis; CHROMATOGRAPHY-MASS SPECTROMETRY; EXTRACTION-GAS CHROMATOGRAPHY; PHASE MICROEXTRACTION; FOODS; SPME; METHYLFURAN; FLAVORS; SYSTEMS; MODEL; MS;
D O I
10.1016/j.chroma.2010.12.002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The study compares standard addition (SA), stable isotope dilution assay (SIDA) and multiple headspace extraction (MHE) as methods to quantify furan and 2-methyl-furan in roasted coffee with HS-SPME-GC-MS, using CAR-PDMS as fibre coating, d(4)-furan as internal standard and in-fibre internal standardization with n-undecane to check the fibre reliability. The results on about 150 samples calculated with the three quantitation approaches were all very satisfactory, with coefficient of variation (CV) versus the U.S. Food and Drug Administration (FDA) method, taken as reference, almost always below the arbitrarily-fixed limit of 15%. Furan was detected in the 1-5 ppm range, 2-methyl-furan in the 4-20 ppm range. Moreover, experimental exponential slopes (Q) and linearity (r) of both furan and 2-methyl-furan MHE regression equation on 50 samples were very similar thus making possible to use the same average Q value for all samples of the investigated set and their quantitation with a single determination. This makes this approach very rapid and competitive in-time with SA and SIDA. A non-separative method (HS-SPME-MS) was also developed in view of possible application on-line monitoring of furan and 2-methyl-furan in a pilot-plant with the aim of optimizing the roasting process to reduce these compounds to a minimum. Sampling times of 20 and 5 min were tested, the latter enabling total analysis time to be reduced to about 9 min. The results on 105 samples with both SIDA and MHE approaches were again highly satisfactory most of the samples giving a CV% versus the conventional methods below 20%. In this case too average Q values for both furan and 2-methyl-furan were used for MHE. The separative method presented very good repeatability (RSD% always below 10%) and intermediate precision over three months (RSD% always below 15%); performance were similar for the non-separative method, with repeatability (RSD%) always below 12% and intermediate precision over three months (RSD%) always below 15%. The sensitivity of both separative and non-separative methods was also very good, LOD and LOQ being in the ppb range for both furan and 2-methyl-furan, i.e. well below the amounts present in the roasted coffee samples. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:753 / 762
页数:10
相关论文
共 43 条
  • [1] Analysis of furan in foods by headspace solid-phase microextraction-gas chromatography-ion trap mass spectrometry
    Altaki, M. S.
    Santos, F. J.
    Galceran, M. T.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1146 (01) : 103 - 109
  • [2] Automated headspace solid-phase microextraction versus headspace for the analysis of furan in foods by gas chromatography-mass spectrometry
    Altaki, M. S.
    Santos, F. J.
    Galceran, M. T.
    [J]. TALANTA, 2009, 78 (4-5) : 1315 - 1320
  • [3] [Anonymous], 2004, EFSA Journal, V137, P1
  • [4] [Anonymous], 2004, DETERMINATION FURAN
  • [5] [Anonymous], 2004, DET FUR FOODS
  • [6] Becalski A, 2005, J AOAC INT, V88, P102
  • [7] Development of an analytical method and survey of foods for furan, 2-methylfuran and 3-methylfuran with estimated exposure
    Becalski, A.
    Hayward, S.
    Krakalovich, T.
    Pelletier, L.
    Roscoe, V.
    Vavasour, E.
    [J]. FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2010, 27 (06): : 764 - 775
  • [8] Development and validation of a solid phase micro-extraction-gas chromatography-mass spectrometry method for the determination of furan in baby-food
    Bianchi, F
    Careri, M
    Mangia, A
    Musci, M
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1102 (1-2) : 268 - 272
  • [9] A survey on high-concentration-capability headspace sampling techniques in the analysis of flavors and fragrances
    Bicchi, C
    Cordero, C
    Rubiolo, P
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2004, 42 (08) : 402 - 409
  • [10] Headspace sampling of the volatile fraction of vegetable matrices
    Bicchi, Carlo
    Cordero, Chiara
    Liberto, Erica
    Sgorbini, Barbara
    Rubiolo, Patrizia
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) : 220 - 233