Nusselt number correlation for turbulent heat transfer of helium-xenon gas mixtures

被引:13
作者
Zhou, Biao [1 ]
Ji, Yu [1 ]
Sun, Jun [1 ]
Sun, Yu-Liang [1 ]
机构
[1] Tsinghua Univ, Inst Nucl & New Energy Technol, Key Lab Adv Reactor Engn & Safety, Minist Educ, Beijing 100084, Peoples R China
关键词
Gas-cooled nuclear reactor; Space nuclear power; Helium-xenon mixtures; Convective heat transfer; Nusselt number; PRANDTL-NUMBER; BINARY-MIXTURES; FORCED-CONVECTION; MASS-TRANSFER; FLOW; REACTOR; TEMPERATURE; PREDICTION; BRAYTON; EQUATIONS;
D O I
10.1007/s41365-021-00972-1
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A gas-cooled nuclear reactor combined with a Brayton cycle shows promise as a technology for high-power space nuclear power systems. Generally, a helium-xenon gas mixture with a molecular weight of 14.5-40.0 g/mol is adopted as the working fluid to reduce the mass and volume of the turbomachinery. The Prandtl number for helium-xenon mixtures with this recommended mixing ratio may be as low as 0.2. As the convective heat transfer is closely related to the Prandtl number, different heat transfer correlations are often needed for fluids with various Prandtl numbers. Previous studies have established heat transfer correlations for fluids with medium-high Prandtl numbers (such as air and water) and extremely low-Prandtl fluids (such as liquid metals); however, these correlations cannot be directly recommended for such helium-xenon mixtures without verification. This study initially assessed the applicability of existing Nusselt number correlations, finding that the selected correlations are unsuitable for helium-xenon mixtures. To establish a more general heat transfer correlation, a theoretical derivation was conducted using the turbulent boundary layer theory. Numerical simulations of turbulent heat transfer for helium-xenon mixtures were carried out using Ansys Fluent. Based on simulated results, the parameters in the derived heat transfer correlation are determined. It is found that calculations using the new correlation were in good agreement with the experimental data, verifying its applicability to the turbulent heat transfer for helium-xenon mixtures. The effect of variable gas properties on turbulent heat transfer was also analyzed, and a modified heat transfer correlation with the temperature ratio was established. Based on the working conditions adopted in this study, the numerical error of the property-variable heat transfer correlation was almost within 10%.
引用
收藏
页数:15
相关论文
共 47 条
  • [21] Kays W.M., 2011, Convective heat and mass transfer
  • [22] TURBULENT PRANDTL NUMBER - WHERE ARE WE
    KAYS, WM
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1994, 116 (02): : 284 - 295
  • [23] Design of a hundred-kilowatt level integrated gas-cooled space nuclear reactor for deep space application
    Li, Zeguang
    Sun, Jun
    Liu, Malin
    Lang, Minggang
    Shi, Lei
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2020, 361
  • [24] LYON RN, 1951, CHEM ENG PROG, V47, P75
  • [25] Mason LS, 2001, AIP CONF PROC, V552, P1017, DOI 10.1063/1.1358045
  • [26] Computational flow and heat transfer design and analysis for 1/12 gas-cooled space nuclear reactor
    Meng, Tao
    Cheng, Kun
    Zhao, Fulong
    Xia, Chenchao
    Tan, Sichao
    [J]. ANNALS OF NUCLEAR ENERGY, 2020, 135
  • [27] SOLUTION TO TURBULENT GRAETZ PROBLEM .3. FULLY DEVELOPED AND ENTRY REGION HEAT-TRANSFER RATES
    NOTTER, RH
    SLEICHER, CA
    [J]. CHEMICAL ENGINEERING SCIENCE, 1972, 27 (11) : 2073 - &
  • [28] HEATED TURBULENT-FLOW OF HELIUM-ARGON MIXTURES IN TUBES
    PICKETT, PE
    TAYLOR, MF
    MCELIGOT, DM
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1979, 22 (05) : 705 - 719
  • [29] NOTE ON THE HISTORY OF THE REYNOLDS-NUMBER
    ROTT, N
    [J]. ANNUAL REVIEW OF FLUID MECHANICS, 1990, 22 : 1 - 11
  • [30] Schlichting H, 1979, Boundary-Layer Theory, DOI DOI 10.1007/978-3-662-52919-5