Mass spectrometric techniques for label-free high-throughput screening in drug discovery

被引:63
作者
Roddy, Thomas P. [1 ]
Horvath, Christopher R. [1 ]
Stout, Steven J. [1 ]
Kenney, Kristin L. [1 ]
Ho, Pei-I [1 ]
Zhang, Ji-Hu [1 ]
Vickers, Chad [1 ]
Kaushik, Virendar [1 ]
Hubbard, Brian [1 ]
Wang, Y. Karen [1 ]
机构
[1] Novartis Inst Biomed Res, Cambridge, MA 02139 USA
关键词
D O I
10.1021/ac062421q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High-throughput screening (HTS) is an important tool for finding active compounds to initiate medicinal chemistry programs in pharmaceutical discovery research. Traditional HTS methods rely on fluorescent or radiolabeled reagents and/or coupling assays to permit quantitation of enzymatic target inhibition or activation. Mass spectrometry-based high-throughput screening (MS-HTS) is an alternative that is not susceptible to the limitations imposed by labeling and coupling enzymes. MS-HTS offers a selective and sensitive analytical method for unlabeled substrates and products. Furthermore, method development times are reduced without the need to incorporate labels or coupling assays. MS-HTS also permits screening of targets that are difficult or impossible to screen by other techniques. For example, enzymes that are challenging to purify can lead to the nonspecific detection of structurally similar components of the impure enzyme or matrix of membraneous enzymes. The high selectivity of tandem mass spectrometry (MS/MS) enables these screens to proceed with low levels of background noise to sensitively discover interesting hits even with relatively weak activity. In this article, we describe three techniques that we have adapted for large-scale (similar to 175 000 sample) compound library screening, including four-way parallel multiplexed electrospray liquid chromatography tandem mass spectrometry (MUX-LC/MS/MS), four-way parallel staggered gradient liquid chromatography tandem mass spectrometry (LC/MS/MS), and eight-way staggered flow injection MS/MS following 384-well plate solid-phase extraction (S:PE). These methods are capable of analyzing a 384-well plate in 37 min, with typical analysis times of less than 2 h. The quality of the MS-HTS approach is demonstrated herein with screening data from two large-scale screens.
引用
收藏
页码:8207 / 8213
页数:7
相关论文
共 25 条
[1]  
Biddlecombe RA, 2001, RAPID COMMUN MASS SP, V15, P33, DOI 10.1002/1097-0231(20010115)15:1<33::AID-RCM188>3.0.CO
[2]  
2-4
[3]   Looking towards label-free biomolecular interaction analysis in a high-throughput format: a review of new surface plasmon resonance technologies [J].
Boozer, Christina ;
Kim, Gibum ;
Cong, Shuxin ;
Guan, HannWen ;
Londergan, Timothy .
CURRENT OPINION IN BIOTECHNOLOGY, 2006, 17 (04) :400-405
[4]   Description and validation of a four-channel staggered LC-MS/MS system for high-throughput in vitro screens [J].
Briem, S ;
Pettersson, B ;
Skoglund, E .
ANALYTICAL CHEMISTRY, 2005, 77 (06) :1905-1910
[5]   Frontal affinity chromatography-mass spectrometry assay technology for multiple stages of drug. discovery: applications of a chromatographic biosensor [J].
Chan, NWC ;
Lewis, DF ;
Rosner, PJ ;
Kelly, MA ;
Schriemer, DC .
ANALYTICAL BIOCHEMISTRY, 2003, 319 (01) :1-12
[6]  
de Biasi V, 1999, RAPID COMMUN MASS SP, V13, P1165, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1165::AID-RCM638>3.0.CO
[7]  
2-4
[8]   Applications of mass spectrometry in early stages of target based drug discovery [J].
Deng, GJ ;
Sanyal, G .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (03) :528-538
[9]   High-speed gradient parallel liquid chromatography/tandem mass spectrometry with fully automated sample preparation for bioanalysis: 30 seconds per sample from plasma [J].
Deng, Y ;
Wu, JT ;
Lloyd, TL ;
Chi, CL ;
Olah, TV ;
Unger, SE .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (11) :1116-1123
[10]   Statistical evaluation of a self-deconvoluting matrix strategy for high-throughput screening of the CXCR3 receptor [J].
Ferrand, S ;
Schmid, A ;
Engeloch, C ;
Glickman, JF .
ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2005, 3 (04) :413-424