Capacitance electrochemical biosensor based on silicon nitride transducer for TNF-α cytokine detection in artificial human saliva: Heart failure (HF)

被引:40
作者
Bahri, Mohamed [1 ,2 ]
Baraket, Abdoullatif [3 ]
Zine, Nadia [3 ]
Ben Ali, Mounir [1 ,2 ]
Bausells, Joan [4 ]
Errachid, Abdelhamid [3 ]
机构
[1] Ctr Res Microelect & Nanotechnol Sousse, LR16CRMN01, NANOMISENE Lab, Technopole Sousse BP 334, Sahloul 4034, Sousse, Tunisia
[2] Univ Sousse, Higher Inst Appl Sci & Technol Sousse, GREENS ISSAT, Ibn Khaldoun Sousse 4003, Tunisia
[3] Univ Lyon 1, Univ Lyon, CNRS, Inst Sci Analyt,ENS Lyon,UMR 5280, 5 Rue Doua, F-69100 Villeurbanne, France
[4] CSIC, CNM, IMB, Barcelona Microelect Inst, Bellaterra, Spain
关键词
Electrochemical biosensor; Mott-Schottky; Silicon nitride transducer; Tumour Necrosis Factor; Human artificial saliva; TUMOR-NECROSIS-FACTOR; SENSITIVE IMMUNOASSAY; SERUM; NANOPARTICLES; IMMUNOSENSOR; POLYMER; SENSORS; CANCER; CHIP;
D O I
10.1016/j.talanta.2019.120501
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present study, we have developed a capacitance electrochemical biosensor based on silicon nitride substrate (Si3N4/SiO2/Si[P]/Al) for Tumour Necrosis Factor Alpha (TNF-alpha) cytokines detection. Micro-contact printing, Fluorescence microscopy characterization and contact angle measurement (CAM) were carried out during the bio-functionalization of the biosensor surface. Mott-Schottky analyses were applied for TNF-alpha detection within the range of 1 pg/mL to 30 pg/mL in which the immunosensor has exhibited a good linearity, a sensitivity of 4 mV.pM(-1) and 4.4 mV.pM(-1) in PBS and artificial saliva (AS) respectively. While the LOD was found at 0.38 pg/mL and 1 pg/mL in PBS and AS respectively. The developed immunosensor has also demonstrated a high and good selectivity for TNF-alpha detection in human AS when compared to other interferences like Cortisol and Interleukin-10. The performances of the developed biosensor are very promising for biomedical application to predict the first sign of inflammation.
引用
收藏
页数:7
相关论文
共 51 条
[1]   The Global Health and Economic Burden of Hospitalizations for Heart Failure Lessons Learned From Hospitalized Heart Failure Registries [J].
Ambrosy, Andrew P. ;
Fonarow, Gregg C. ;
Butler, Javed ;
Chioncel, Ovidiu ;
Greene, Stephen J. ;
Vaduganathan, Muthiah ;
Nodari, Savina ;
Lam, Carolyn S. P. ;
Sato, Naoki ;
Shah, Ami N. ;
Gheorghiade, Mihai .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) :1123-1133
[2]  
[Anonymous], [No title captured]
[3]  
[Anonymous], [No title captured]
[4]  
[Anonymous], [No title captured]
[5]  
[Anonymous], 2008, J AM DENT ASS
[6]  
[Anonymous], [No title captured]
[7]   Lung Cancer and Its Early Detection Using Biomarker-Based Biosensors [J].
Arya, Sunil K. ;
Bhansali, Shekhar .
CHEMICAL REVIEWS, 2011, 111 (11) :6783-6809
[8]   Spectroscopic and microscopic characterization of biosensor surfaces with protein/amino-organosilane/silicon structure [J].
Awsiuk, K. ;
Bernasik, A. ;
Kitsara, M. ;
Budkowski, A. ;
Petrou, P. ;
Kakabakos, S. ;
Prauzner-Bechcicki, S. ;
Rysz, J. ;
Raptis, I. .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2012, 90 :159-168
[9]   A highly sensitive immunosensor based on ITO thin films covered by a new semi-conductive conjugated polymer for the determination of TNFα in human saliva and serum samples [J].
Aydin, Elif Burcu ;
Aydin, Muhammet ;
Sezginturk, Mustafa Kemal .
BIOSENSORS & BIOELECTRONICS, 2017, 97 :169-176
[10]   A flexible electrochemical micro lab-on-chip: application to the detection of interleukin-10 [J].
Baraket, Abdoullatif ;
Lee, Michael ;
Zine, Nadia ;
Yaakoubi, Nourdin ;
Bausells, Joan ;
Errachid, Abdelhamid .
MICROCHIMICA ACTA, 2016, 183 (07) :2155-2162