Pulmonary Bleeding During Right Ventricular Support After Left Ventricular Assist Device Implantation

被引:15
|
作者
Welp, Henryk [1 ]
Sindermann, Juegen R. [1 ]
Deschka, Heinz [1 ]
Martens, Sven [1 ]
Scherer, Mirela [1 ]
机构
[1] Univ Hosp Munster, Div Cardiac Surg, Dept Cardiothorac Surg, Albert Schweitzer Campus 1, D-48149 Munster, Germany
关键词
bleeding; circulatory support devices; temporary circulatory support; extracorporeal membrane oxygenation; lung; right ventricular support; LVAD; RVAD; EXTRACORPOREAL MEMBRANE-OXYGENATION; CIRCULATORY SUPPORT; ARTERIAL-HYPERTENSION; HEART-FAILURE; SURGICAL MODALITIES; COMPLICATIONS; PATIENT; SYSTEM; MODEL;
D O I
10.1053/j.jvca.2015.07.012
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objectives: Right heart failure still occurs in up to 20% of patients after implantation of a left ventricular assist device (LVAD). One treatment option for these patients is the implantation of a temporary right ventricular assist device (RVAD). Experimental data suggest that non-pulsatile perfusion of the lungs is associated with an increased rate of pulmonary hemorrhage. The aim of this study was to determine the incidence of pulmonary bleeding complications in these patients. Design: Observational study. Setting: Single center, university hospital. Participants: This study included patients undergoing LVAD implantation for end-stage heart failure and subsequent implantation of a temporary right ventricular support system. Interventions: In this study, 25 patients who underwent LVAD and additional temporary RVAD implantation were screened for pulmonary bleeding complications. Measurements and Main Results: The mean Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) level at the time of LVAD implantation was 2.84. All patients experienced severe right ventricular failure (tricuspid annular plane systolic excursion [TAPSE], 10.16 +/- 26.3 mm) and severe pulmonary hypertension (right atrial [RA] pressure, 56.21 +/- 15.58 mmHg). Average duration of right ventricular support was 11.12 +/- 7.20 days, with right ventricular support being administered to 14 patients for more than 7 days. Seventeen patients were weaned successfully from right ventricular support after a mean support duration of 5 days. Five patients developed pulmonary bleeding complications, diagnosed using computed tomography scan and bronchoscopy. All bleeding occurred after postoperative day 7 and was associated with RVAD flow of more than 4 L/min within 24 hours before bleeding occurred. Conclusions: The data presented in this study suggested that right ventricular support for more than 7 days and a blood flow greater than 4 L/min were associated with pulmonary bleeding complications. This should be taken into consideration when temporary right ventricular support after LVAD implantation is planned. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:627 / 631
页数:5
相关论文
共 50 条
  • [1] Right Ventricular Assist Device Placement During Left Ventricular Assist Device Implantation Is Associated With Improved Survival
    Crespo-Diaz, Ruben
    Mudy, Karol
    Khan, Nadeem
    Samara, Michael
    Eckman, Peter M.
    Sun, Benjamin
    Hryniewicz, Katarzyna
    ASAIO JOURNAL, 2024, 70 (07) : 570 - 577
  • [2] Minimal invasive temporary percutaneous right ventricular circulatory support after left ventricular assist device implantation
    Natanov, Ruslan
    Ricklefs, Marcel
    Madrahimov, Nodir
    Fleissner, Felix
    Haverich, Axel
    Kuhn, Christian
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2021, 33 (05) : 795 - 800
  • [3] Outcome of unplanned right ventricular assist device support for severe right heart failure after implantable left ventricular assist device insertion
    Takeda, Koji
    Naka, Yoshifumi
    Yang, Jonathan A.
    Uriel, Nir
    Colombo, Paolo C.
    Jorde, Ulrich P.
    Takayama, Hiroo
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (02) : 141 - 148
  • [4] Extracorporeal membrane oxygenation support for right ventricular failure after left ventricular assist device implantation
    Riebandt, Julia
    Haberl, Thomas
    Wiedemann, Dominik
    Moayedifar, R.
    Schloeglhofer, Thomas
    Mahr, Stephane
    Dimitrov, Kamen
    Angleitner, Philipp
    Laufer, Guenther
    Zimpfer, Daniel
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (03) : 590 - 595
  • [5] Pulmonary artery pulsatility index predicts right ventricular failure after left ventricular assist device implantation
    Kang, Guson
    Ha, Richard
    Banerjee, Dipanjan
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (01) : 67 - 73
  • [6] Right ventricular failure after left ventricular assist device implantation: a review of the literature
    Coco, Valeria Lo
    Piero, Maria Elena De
    Massimi, Giulio
    Chiarini, Giovanni
    Raffa, Giuseppe M.
    Kowalewski, Mariusz
    Maessen, Jos
    Lorusso, Roberto
    JOURNAL OF THORACIC DISEASE, 2021, 13 (02) : 1256 - 1269
  • [7] Postoperative Pulmonary Artery Pulsatility Index Improves Prediction of Right Ventricular Failure After Left Ventricular Assist Device Implantation
    Wei, Johnny
    Franke, Jack
    Kee, Abigail
    Dukes, Rachel
    Leonardo, Vincent
    Flynn, Brigid C.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2024, 38 (01) : 214 - 220
  • [8] Alternative right ventricular assist device implantation technique for patients with perioperative right ventricular failure
    Saeed, Diyar
    Maxhera, Bujar
    Kamiya, Hiroyuki
    Lichtenberg, Artur
    Albert, Alexander
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 149 (03) : 927 - 932
  • [9] Timing of Temporary Right Ventricular Assist Device Insertion for Severe Right Heart Failure After Left Ventricular Assist Device Implantation
    Takeda, Koji
    Naka, Yoshifumi
    Yang, Jonathan A.
    Uriel, Nir
    Colombo, Paolo C.
    Jorde, Ulrich P.
    Takayama, Hiroo
    ASAIO JOURNAL, 2013, 59 (06) : 564 - 569
  • [10] Right Ventricular Failure After Left Ventricular Assist Device
    Cogswell, Rebecca
    John, Ranjit
    Shaffer, Andrew
    CARDIOLOGY CLINICS, 2020, 38 (02) : 219 - +