Automatic, Operator-adjusted, and Manual Disc-definition for Optic Nerve Head and Retinal Nerve Fiber Layer Measurements With the RTVue-100 Optical Coherence Tomograph

被引:12
作者
Garas, Anita [1 ]
Vargha, Peter [2 ]
Hollo, Gabor [1 ]
机构
[1] Semmelweis Univ, Dept Ophthalmol, H-1083 Budapest, Hungary
[2] Semmelweis Univ, Ctr Cardiovasc, H-1083 Budapest, Hungary
关键词
disc definition; glaucoma; RTVue Fourier-domain optical coherence tomography; repeatability; diagnostic classification; FOURIER-DOMAIN; THICKNESS; GLAUCOMA; ATROPHY;
D O I
10.1097/IJG.0b013e3181d787fd
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the repeatability and between-methods differences of optic nerve head and retinal nerve fiber layer thickness (RNFLT) measurements as made with the automatic, operator-adjusted, and manual disc-definition functions of the RTVue-100 Fourier-domain optical coherence tomograph. Methods: One eye of each of 126 persons (72 glaucomatous, 10 ocular hypertensive, 44 healthy control eyes) was analyzed with all 3 disc-definition functions. Thirty-three eyes were imaged 5 times for the determination of measurement repeatability. Results: For several parameters, repeatability with automatic disc definition was significantly poorer than the other options. In contrast, for all but 1 parameter repeatability did not differ between the manual and operator-adjusted methods. Refractive error, disease category or peripapillary atrophy had no influence on repeatability. However, the measured values differed significantly between the methods, for all but 3 parameters. Similar between-method differences were seen for eyes irrespective of glaucoma, refractive error, or parapapillary atrophy. High intraclass correlation (93.5% to 99.9%) was seen for all parameters measured with manual and operator-adjusted methods, but in the other comparisons only for RNFLT parameters. Agreement of the classifications was better for RNFLT parameters than disc parameters, and the k-values were highest (0.881 to 0.968) in comparing the manual and operator-adjusted methods. Conclusions: Measurement repeatability with manual and operator-adjusted disc-definition functions is similar and is not influenced by refractive error, glaucoma, or parapapillary atrophy. The high intraclass correlation and the agreement of diagnostic classifications suggest that operator-adjusted disc-definition can be useful for glaucoma detection with the RTVue-100 Fourier-domain optical coherence tomograph.
引用
收藏
页码:80 / 86
页数:7
相关论文
共 21 条
[1]   Relationship between visual field sensitivity and retinal nerve fiber layer thickness as measured by optical coherence tomography [J].
Ajtony, Csilla ;
Balla, Zsolt ;
Somoskeoy, Szabolcs ;
Kovacs, Balint .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (01) :258-263
[2]  
[Anonymous], OPHTHALMOLO IN PRESS
[3]  
[Anonymous], 2008, TERMINOLOGY GUIDELIN, V3rd
[4]  
[Anonymous], OPHTHALMOLOGY
[5]  
[Anonymous], RNFL PROGRESSION ANA
[6]  
[Anonymous], J GLAUCOMA IN PRESS
[7]   Thickness Profiles of Retinal Layers by Optical Coherence Tomography Image Segmentation [J].
Bagci, Ahmet Murat ;
Shahidi, Mahnaz ;
Ansari, Rashid ;
Blair, Michael ;
Blair, Norman Paul ;
Zelkha, Ruth .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (05) :679-687
[8]   Effects of scan circle displacement in optical coherence tomography retinal nerve fibre layer thickness measurement: a RNFL modelling study [J].
Cheung, C. Y. L. ;
Yiu, C. K. F. ;
Weinreb, R. N. ;
Lin, D. ;
Li, H. ;
Yung, A. Y. ;
Pang, C. P. ;
Lam, D. S. C. ;
Leung, C. K. S. .
EYE, 2009, 23 (06) :1436-1441
[9]   Comparison of Fourier-Domain and Time-Domain Optical Coherence Tomography in the Detection of Band Atrophy of the Optic Nerve [J].
Costa-Cunha, Luciana V. F. ;
Cunha, Leonardo P. ;
Malta, Roberto F. S. ;
Monteiro, Mario L. R. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (01) :56-63
[10]   Reproducibility of RTVue Retinal Nerve Fiber Layer Thickness and Optic Disc Measurements and Agreement with Stratus Optical Coherence Tomography Measurements [J].
Gonzalez-Garcia, Alberto O. ;
Vizzeri, Gianmarco ;
Bowd, Christopher ;
Medeiros, Felipe A. ;
Zangwill, Linda M. ;
Weinreb, Robert N. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (06) :1067-1074