Study of the X-ray energy utilization efficiency of the X-ray digital imaging systems in industrial applications

被引:3
作者
Li Ruihong [1 ]
Han Yueping [1 ]
机构
[1] N Univ China, Natl Key Lab Elect Measurement Technol, Taiyuan 030051, Peoples R China
基金
中国国家自然科学基金;
关键词
X-ray imaging system; Optimized design; Energy utilization efficiency; Focal length; DOSE UNIFORMITY; DETECTOR; RESOLUTION; RANGE; BEAM;
D O I
10.1016/j.nima.2010.05.036
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The purpose of the present paper is to study the X-ray energy utilization efficiency that is inherent in the improved design of actual X-ray digital imaging systems in industrial applications. Both the X-ray energy utilization efficiency and the light intensity of the X-ray beam are lowered distinctly while the distance of the focal length is increased for high spatial resolution and high sensitivity. Furthermore, the utilization efficiency is even lowered for improving the tube current to maintain the light intensity. The theoretical analysis and the experimental results show that the sensitivity, spatial resolution and Xray energy utilization efficiency should be synthetically considered in an optimized X-ray imaging system. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:368 / 372
页数:5
相关论文
共 13 条
[1]   Improvement of image resolution and quantitative accuracy in clinical Single Photon Emission Computed Tomography [J].
Beekman, FJ ;
Kamphuis, C ;
King, MA ;
van Rijk, PP ;
Viergever, MA .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2001, 25 (02) :135-146
[2]   Development of an advanced X-ray detector for inspecting inner microscopic structural details in industrial applications [J].
Han, Yueping ;
Han, Yan ;
Li, Ruihong ;
Li, Haiting .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 600 (02) :440-444
[3]   Study of a new X-ray gaseous detector [J].
Ismaili, Y ;
Fontbonne, JM ;
Mosrin, P ;
Tamain, B ;
Tillier, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 423 (01) :68-74
[4]   An increase of utilization efficiency of X-ray beam [J].
Lazurik, V. T. ;
Pismenesky, S. A. ;
Popov, G. F. ;
Rudychev, D. V. ;
Rudychev, V. G. .
RADIATION PHYSICS AND CHEMISTRY, 2007, 76 (11-12) :1787-1791
[5]   Improving spatial resolution in SPECT with the combination of PSPMT based detector and iterative reconstruction algorithms [J].
Loudos, GK ;
Nikita, KS ;
Uzunoglu, NK ;
Giokaris, ND ;
Papanicolas, CN ;
Archimandritis, SC ;
Varvarigou, D ;
Maintas, D .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2003, 27 (04) :307-313
[6]   BEAM SCANNING FOR DOSE UNIFORMITY [J].
MCKEOWN, J ;
CRAIG, ST ;
DREWELL, NH ;
FRKETICH, G ;
SMYTH, DL .
RADIATION PHYSICS AND CHEMISTRY, 1995, 46 (4-6) :1363-1372
[7]   Development of a dual-detector X-ray imaging system for phase retrieval study [J].
Meng, Fanbo ;
Yan, Aimin ;
Zhou, Ge ;
Wu, Xizeng ;
Liu, Hong .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 254 (02) :300-306
[8]   Evaluation of the GSO:Ce scintillator in the X-ray energy range from 40 to 140 kV for possible applications in medical X-ray imaging [J].
Nikolopoulos, D. ;
Valais, I. ;
Kandarakis, I. ;
Cavouras, D. ;
Linardatos, D. ;
Sianoudis, I. ;
Louizi, A. ;
Dimitropoulos, N. ;
Vattis, D. ;
Episkopakis, A. ;
Nomicos, C. ;
Panayiotakis, G. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 560 (02) :577-583
[9]   Digital radiography using an EBCCD-based imaging device [J].
Rossi, M ;
Casali, F ;
Golovkin, SV ;
Covorun, VN .
APPLIED RADIATION AND ISOTOPES, 2000, 53 (4-5) :699-709
[10]   The Palletron™:: a high-dose uniformity pallet irradiator with X-rays [J].
Stichelbaut, F ;
Bol, JL ;
Cleland, MR ;
Grégoire, O ;
Herer, AS ;
Jongen, Y ;
Mullier, B .
RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (1-2) :291-295