Use of electronic monitoring devices to measure antiretroviral adherence: Practical considerations

被引:100
作者
Bova, CA
Fennie, KP
Knafl, GJ
Dieckhaus, KD
Watrous, E
Williams, AB
机构
[1] Univ Massachusetts, Grad Sch Nursing, Worcester, MA 01655 USA
[2] Univ Massachusetts, Div Infect Dis, Worcester, MA 01655 USA
[3] Yale Univ, Sch Nursing, New Haven, CT 06536 USA
[4] Univ Connecticut, Ctr Hlth, Dept Infect Dis, Farmington, CT USA
关键词
Electronic Monitoring Device; MEMS caps; antiretroviral adherence; HIV;
D O I
10.1007/s10461-005-1685-0
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The purpose of this paper is to describe electronic monitoring device (EMD) (e.g., MEMS caps) use among HIV-infected adults enrolled in a randomized clinical trial and to make explicit some of the benefits and caveats of using electronic monitoring device technology. This is a descriptive, exploratory study of EMD use among 128 HIV-infected adults treated with at least three antiretroviral agents. Thirty-six percent of the sample admitted that they did not use the EMD consistently. Forty-one percent of the subjects reported taking out more than one dose at a time and 26% reported opening the EMD but not taking the medication. Special subject-related issues accounted for only a small percentage of all reported problems with EMD use (e.g., transient housing, incarceration, substance abuse relapse and drug treatment). Results of this study suggest that EMDs may underestimate antiretroviral adherence among HIV-infected adults. Recommendations for improving EMD data quality are presented.
引用
收藏
页码:103 / 110
页数:8
相关论文
共 24 条
[1]  
[Anonymous], 2001, AIDS and Behavior
[2]  
Bangsberg D.R., 2001, AIDS Behav, V5, P275, DOI [10.1023/A:1011396711486, DOI 10.1023/A:1011396711486]
[3]   Adherence to protease inhibitors, HIV-1 viral load, and development of drug resistance in an indigent population [J].
Bangsberg, DR ;
Hecht, FM ;
Charlebois, ED ;
Zolopa, AR ;
Holodniy, M ;
Sheiner, L ;
Bamberger, JD ;
Chesney, MA ;
Moss, A .
AIDS, 2000, 14 (04) :357-366
[4]   Adherence to single daily dose of aspirin in a chemoprevention trial - An evaluation of self-report and microelectronic monitoring [J].
Burney, KD ;
Krishnan, K ;
Ruffin, MT ;
Zhang, DW ;
Brenner, DE .
ARCHIVES OF FAMILY MEDICINE, 1996, 5 (05) :297-300
[5]   COMPLIANCE DECLINES BETWEEN CLINIC VISITS [J].
CRAMER, JA ;
SCHEYER, RD ;
MATTSON, RH .
ARCHIVES OF INTERNAL MEDICINE, 1990, 150 (07) :1509-1510
[6]   HOW OFTEN IS MEDICATION TAKEN AS PRESCRIBED - A NOVEL ASSESSMENT TECHNIQUE [J].
CRAMER, JA ;
MATTSON, RH ;
PREVEY, ML ;
SCHEYER, RD ;
OUELLETTE, VL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1989, 261 (22) :3273-3277
[7]  
Dunbar-Jacob J, 2000, Annu Rev Nurs Res, V18, P48
[8]   Methods for measuring and monitoring medication regimen adherence in clinical trials and clinical practice [J].
Farmer, KC .
CLINICAL THERAPEUTICS, 1999, 21 (06) :1074-1090
[9]   Antiretroviral medication compliance in patients with AIDS [J].
Frick, PA ;
Gal, P ;
Lane, TW ;
Sewell, PC .
AIDS PATIENT CARE AND STDS, 1998, 12 (06) :463-470
[10]   Discrimination between rival dosing histories [J].
Jonsson, EN ;
Wade, JR ;
Almqvist, G ;
Karlsson, MO .
PHARMACEUTICAL RESEARCH, 1997, 14 (08) :984-991