Direct Liquid Sampling for Corona Discharge Ion Mobility Spectrometry

被引:12
作者
Sabo, Martin [1 ]
Malaskova, Michaela [1 ]
Harmathova, Olga [1 ]
Hradski, Jasna [2 ]
Masar, Marian [2 ]
Radjenovic, Branislav [3 ]
Matejcik, Stefan [1 ]
机构
[1] Comenius Univ, Fac Math Phys & Informat, Dept Expt Phys, Bratislava 84248, Slovakia
[2] Comenius Univ, Fac Nat Sci, Dept Analyt Chem, Bratislava 84215, Slovakia
[3] Univ Belgrade, Inst Phys, Belgrade 11080, Serbia
关键词
MASS-SPECTROMETRY; ORGANIC-COMPOUNDS; IONIZATION; EXPLOSIVES; MICROEXTRACTION; EXTRACTION;
D O I
10.1021/acs.analchem.5b01585
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a new technique suitable for direct liquid sampling and analysis by ion mobility spectrometry (IMS), The technique is based on introduction of a droplet stream to the IMS reaction region. The technique was successfully used to detect explosives dissolved in methanol and oil as well as to analyze amino acids and dipeptides. One of the main advantages of this technique is its ability to analyze liquid samples without the requirement of any special solution.
引用
收藏
页码:7389 / 7394
页数:6
相关论文
共 29 条
  • [1] Sample-introduction systems coupled to ion-mobility spectrometry equipment for determining compounds present in gaseous, liquid and solid samples
    Arce, L.
    Menendez, M.
    Garrido-Delgado, R.
    Valcarcel, M.
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (02) : 139 - 150
  • [2] Asbury GR, 2000, TALANTA, V50, P1291
  • [3] Ion mobility spectrometry coupled with multi-capillary columns for metabolic profiling of human breath
    Baumbach, Joerg Ingo
    [J]. JOURNAL OF BREATH RESEARCH, 2009, 3 (03)
  • [4] Electrospray ionization nigh-resolution ion mobility spectrometry for the detection of organic compounds, 1. Amino acids
    Beegle, LW
    Kanik, I
    Matz, L
    Hill, HH
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (13) : 3028 - 3034
  • [5] Recent Developments in Ion Mobility Spectrometry
    Borsdorf, Helko
    Mayer, Thomas
    Zarejousheghani, Mashaalah
    Eiceman, Gary A.
    [J]. APPLIED SPECTROSCOPY REVIEWS, 2011, 46 (06) : 472 - 521
  • [6] Comparison of reactant and analyte ions for 63Nickel, corona discharge, and secondary electrospray ionization sources with ion mobility-mass spectrometry
    Crawford, C. L.
    Hill, H. H.
    [J]. TALANTA, 2013, 107 : 225 - 232
  • [7] Membrane-Extraction Ion Mobility Spectrometry for in Situ Detection of Chlorinated Hydrocarbons in Water
    Du, Yongzhai
    Zhang, Wei
    Whitten, William
    Li, Haiyang
    Watson, David B.
    Xu, Jun
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (10) : 4089 - 4096
  • [8] Metabolic profiling of human blood by high-resolution ion mobility mass spectrometry (IM-MS)
    Dwivedi, Prabha
    Schultz, Albert J.
    Hill, Herbert H., Jr.
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 298 (1-3) : 78 - 90
  • [9] Eiceman GA, 2014, ION MOBILITY SPECTROMETRY, 3RD EDITION, P1
  • [10] Chemical standards in ion mobility spectrometry
    Eiceman, GA
    Nazarov, EG
    Stone, JA
    [J]. ANALYTICA CHIMICA ACTA, 2003, 493 (02) : 185 - 194