Simultaneous electrochemical detection of uric acid and ascorbic acid at a silver doped poly(glutamic acid) modified glassy carbon electrode

被引:14
作者
Sun, D. M. [1 ]
Hu, W. N. [1 ]
Ma, W. [1 ]
机构
[1] Huaibei Coal Normal Coll, Dept Chem, Huaibei 235000, Anhui, Peoples R China
关键词
electrochemical detection; glassy carbon electrode; silver dopped poly(glutamic acid); uric acid; ascorbic acid; SELF-ASSEMBLED MONOLAYERS; CAPILLARY-ELECTROPHORESIS; GOLD ELECTRODE; D-SERINE; OXIDATION; ELECTROANALYSIS; EPINEPHRINE; DOPAMINE; XANTHINE; SENSOR;
D O I
10.1134/S1061934811030063
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, the silver doped poly (L-glutamic acid) modified glassy carbon electrode (PLG-Ag/GCE) was fabricated through an electrochemical immobilization. The modified electrode was used for simultaneous determination of uric acid (UA) and ascorbic acid (AA) in 0.1 M phosphate buffer solutions (PBS). The cyclic voltammetric signals of UA and AA were well separated with a potential difference of 396 mV in pH 3.0 phosphate buffer solution. The linear calibration curves were obtained in the concentration range 5.00 x 10(-7)-1.00 x 10(-4) M for UA and 8.00 x 10(-6)-5.00 x 10(-3) M for AA with the detection limits of 3 x 10(-7) M and 4 x 10(-6) M, respectively. The relative standard deviations were 1.3 and 1.0% for the determinations of UA and AA for 20 continuous measurements. The signal was highly stable and reproducible. This method was successfully applied to the determination of UA in human urine samples.
引用
收藏
页码:310 / 316
页数:7
相关论文
共 39 条
[1]   Ascorbic acid: much more than just an antioxidant [J].
Arrigoni, O ;
De Tullio, MC .
BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 2002, 1569 (1-3) :1-9
[2]   Self-assembled monolayers of thio-substituted nucleobases on gold electrode for the electroanalysis of NADH, ethanol and uric acid [J].
Behera, S. ;
Raj, C. Retna .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 128 (01) :31-38
[3]   Possibilities and limitations in miniaturized sensor design for uric acid [J].
Bravo, R ;
Hsueh, C ;
Jaramillo, A ;
Brajter-Toth, A .
ANALYST, 1998, 123 (07) :1625-1630
[4]  
Deng-Ming S, 2007, CHINESE J ANAL CHEM, V35, P1787
[5]   Detection of uric acid with a new type of conducting polymer-based enzymatic sensor by bipotentiostatic technique [J].
Dobay, R ;
Harsányi, G ;
Visy, C .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :187-194
[7]  
DUTT V V S E, 1974, Analytical Chemistry, V46, P1777, DOI 10.1021/ac60348a041
[8]  
Fox B.A., 1989, FOOD SCI NUTR HLTH, V15th
[9]  
Harper H.A., 1977, Review of Physiological Chemistry, V16th
[10]   Growth and electrochemical activity of the poly-L-lysine|poly-L-glutamic acid thin layer films:: an EQCM and electrochemical study [J].
Hoffmannová, H ;
Fermín, D ;
Krtil, P .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 562 (02) :261-265