The effects of center of rotation errors on cardiac SPECT imaging

被引:2
|
作者
Bai, CY [1 ]
Shao, L [1 ]
Ye, JH [1 ]
Durbin, M [1 ]
机构
[1] Philips Med Syst, Milpitas, CA 95035 USA
关键词
cardiac imaging; center of rotation error; lesion-to-background contrast;
D O I
10.1109/TNS.2003.817288
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In SPECT imaging, center of rotation (COR) errors lead to the misalignment of projection data and can potentially degrade the quality of the reconstructed images. In this work, we study the effects of COR errors on cardiac SPECT imaging using simulation, point source, cardiac phantom, and patient studies. For simulation studies, we generate projection data using a uniform MCAT phantom first without modeling any physical effects (NPH), then with the modeling of detector response effect (DR) alone. We then corrupt the projection data with simulated sinusoid and step COR errors. For other studies, we introduce sinusoid COR errors to projection data acquired on SPECT systems. An OSEM algorithm is used for image reconstruction without detector response correction, but with nonuniform attenuation correction when needed. The simulation studies show that, when COR errors increase from 0 to 0.96 cm: 1) sinusoid COR errors in axial direction lead to intensity decrease in the inferoapical region; 2) step COR errors in axial direction lead to intensity decrease in the distal anterior region. The intensity decrease is more severe in images reconstructed from projection data with NPH than with DR; and 3) the effects of COR errors in transaxial direction seem to be insignificant. In other studies, COR errors slightly degrade point source resolution; COR errors of 0.64 cm or above introduce visible but insignificant nonuniformity in the images of uniform cardiac phantom; COR errors up to 0.96 cm in transaxial direction affect the lesion-to-background contrast (LBC) insignificantly in the images of cardiac phantom with defects, and COR errors up to 0.64 cm in axial direction only slightly decrease the LBC. For the patient studies with COR errors up to 0.96 cm, images have the same diagnostic/prognostic values as those without COR errors. This work suggests that COR errors of up to 0.64 cm are not likely to change the clinical applications of cardiac SPECT imaging when using iterative reconstruction algorithm without detector response correction.
引用
收藏
页码:1528 / 1535
页数:8
相关论文
共 50 条
  • [41] Cardiac Imaging Modalities and Appropriate Use
    Peterson, Paul Gabriel
    Berge, Michael
    Lichtenberger, John P., III
    Hood, Maureen N.
    Ho, Vincent B.
    PRIMARY CARE, 2018, 45 (01): : 155 - 168
  • [42] Resolution and Speckle Reduction in Cardiac Imaging
    Bottenus, Nick
    LeFevre, Melissa
    Cleve, Jayne
    Crowley, Anna Lisa
    Trahey, Gregg
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (04) : 1131 - 1143
  • [43] Gating Approaches in Cardiac PET Imaging
    Lassen, Martin Lyngby
    Kwiecinski, Jacek
    Slomka, Piotr J.
    PET CLINICS, 2019, 14 (02) : 271 - +
  • [44] What is new in pediatric cardiac imaging?
    Mertens, Luc
    Ganame, Javier
    Eyskens, Benedicte
    EUROPEAN JOURNAL OF PEDIATRICS, 2008, 167 (01) : 1 - 8
  • [45] The Role of Artificial Intelligence in Cardiac Imaging
    Onnis, Carlotta
    van Assen, Marly
    Muscogiuri, Emanuele
    Muscogiuri, Giuseppe
    Gershon, Gabrielle
    Saba, Luca
    De Cecco, Carlo N.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2024, 62 (03) : 473 - 488
  • [46] Imaging Cardiac Masses in Patients with Cancer
    Prabhu, Nicole
    DeCara, Jeanne M.
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2022, 24 (03): : 186 - 190
  • [47] Incidental Cardiac Findings on Thoracic Imaging
    Kok, Hong Kuan
    Loo, Bryan
    Torreggiani, William C.
    Buckley, Orla
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2013, 64 (04): : 325 - 332
  • [48] Pharmacologic Stress Agents for Cardiac Imaging
    Reyes E.
    Anagnostopoulos C.
    Current Cardiovascular Imaging Reports, 2013, 6 (4) : 369 - 378
  • [49] Pediatric cardiac imaging: the beat goes on!
    Strife, JL
    PEDIATRIC RADIOLOGY, 2006, 36 (07) : 578 - 580
  • [50] Cardiac state driven CT image reconstruction algorithm for cardiac imaging
    Cesmeli, E
    Edic, PM
    Iatrou, M
    Hsieh, J
    Gupta, R
    Pfoh, AH
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 779 - 789