The effects of center of rotation errors on cardiac SPECT imaging

被引:2
|
作者
Bai, CY [1 ]
Shao, L [1 ]
Ye, JH [1 ]
Durbin, M [1 ]
机构
[1] Philips Med Syst, Milpitas, CA 95035 USA
关键词
cardiac imaging; center of rotation error; lesion-to-background contrast;
D O I
10.1109/TNS.2003.817288
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In SPECT imaging, center of rotation (COR) errors lead to the misalignment of projection data and can potentially degrade the quality of the reconstructed images. In this work, we study the effects of COR errors on cardiac SPECT imaging using simulation, point source, cardiac phantom, and patient studies. For simulation studies, we generate projection data using a uniform MCAT phantom first without modeling any physical effects (NPH), then with the modeling of detector response effect (DR) alone. We then corrupt the projection data with simulated sinusoid and step COR errors. For other studies, we introduce sinusoid COR errors to projection data acquired on SPECT systems. An OSEM algorithm is used for image reconstruction without detector response correction, but with nonuniform attenuation correction when needed. The simulation studies show that, when COR errors increase from 0 to 0.96 cm: 1) sinusoid COR errors in axial direction lead to intensity decrease in the inferoapical region; 2) step COR errors in axial direction lead to intensity decrease in the distal anterior region. The intensity decrease is more severe in images reconstructed from projection data with NPH than with DR; and 3) the effects of COR errors in transaxial direction seem to be insignificant. In other studies, COR errors slightly degrade point source resolution; COR errors of 0.64 cm or above introduce visible but insignificant nonuniformity in the images of uniform cardiac phantom; COR errors up to 0.96 cm in transaxial direction affect the lesion-to-background contrast (LBC) insignificantly in the images of cardiac phantom with defects, and COR errors up to 0.64 cm in axial direction only slightly decrease the LBC. For the patient studies with COR errors up to 0.96 cm, images have the same diagnostic/prognostic values as those without COR errors. This work suggests that COR errors of up to 0.64 cm are not likely to change the clinical applications of cardiac SPECT imaging when using iterative reconstruction algorithm without detector response correction.
引用
收藏
页码:1528 / 1535
页数:8
相关论文
共 50 条
  • [21] Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose
    Abdollahi, Hamid
    Shiri, Isaac
    Salimi, Yazdan
    Sarebani, Maghsoud
    Mehdinia, Reza
    Deevband, Mohammad Reza
    Mahdavi, Seied Rabi
    Sohrabi, Ahmad
    Bitarafan-Rajabi, Ahmad
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (12) : 2257 - 2261
  • [22] Easy Method of Patient Positioning for Convergent-Beam Cardiac SPECT
    Zeng, Gengsheng L.
    Christian, Paul E.
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2007, 35 (03) : 131 - 134
  • [23] Synthetic Attenuation Correction Maps for SPECT Imaging Using Deep Learning: A Study on Myocardial Perfusion Imaging
    Canalejo, Mariana Andrea Prieto
    Pedro, Aley Palau San
    Geronazzo, Ricardo
    Minsky, Daniel Mauricio
    Juarez-Orozco, Luis Eduardo
    Namias, Mauro
    DIAGNOSTICS, 2023, 13 (13)
  • [24] Quantitative Flow Cytometry Detects DNA Damage in Patients Undergoing Cardiac SPECT
    Lee, Won H.
    Nguyen, Patricia K.
    Hu, Shijun
    Sanchez-Freire, Veronica
    Narsinh, Kazim
    de Almeida, Patricia
    Lee, Andrew S.
    Segall, George
    Wu, Joseph C.
    CIRCULATION, 2012, 126 (21)
  • [25] Comparison of radionuclide ventriculography using SPECT and planar techniques in different cardiac conditions
    Massardo, Teresa
    Jaimovich, Rodrigo
    Lavados, Hugo
    Gutierrez, Daniela
    Rodriguez, J. Carlos
    Saavedra, J. Miguel
    Alay, Rita
    Gatica, Hector
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (11) : 1735 - 1746
  • [26] Comparison of radionuclide ventriculography using SPECT and planar techniques in different cardiac conditions
    Teresa Massardo
    Rodrigo Jaimovich
    Hugo Lavados
    Daniela Gutiérrez
    J. Carlos Rodríguez
    J. Miguel Saavedra
    Rita Alay
    Héctor Gatica
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 1735 - 1746
  • [27] Cardiac Imaging in Patients With Ventricular Tachycardia
    Mahida, Saagar
    Sacher, Frederic
    Dubois, Remi
    Sermesant, Maxime
    Bogun, Frank
    Haissaguerre, Michel
    Jais, Pierre
    Cochet, Hubert
    CIRCULATION, 2017, 136 (25) : 2491 - +
  • [28] Imaging features of primary cardiac lymphoma
    Coulier, B.
    Colin, G. C.
    Tourmous, H.
    Floris, N.
    Van Eeckhout, P.
    Scavee, C.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2018, 99 (02) : 115 - 117
  • [29] Computed Tomography Imaging of Cardiac Masses
    Young, Phillip M.
    Foley, Thomas A.
    Araoz, Philip A.
    Williamson, Eric E.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2019, 57 (01) : 75 - +
  • [30] Rapid cardiac imaging with turbo BRISK
    Doyle, M
    Walsh, EG
    Foster, RE
    Pohost, GM
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) : 410 - 417