The effects of center of rotation errors on cardiac SPECT imaging

被引:2
|
作者
Bai, CY [1 ]
Shao, L [1 ]
Ye, JH [1 ]
Durbin, M [1 ]
机构
[1] Philips Med Syst, Milpitas, CA 95035 USA
关键词
cardiac imaging; center of rotation error; lesion-to-background contrast;
D O I
10.1109/TNS.2003.817288
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In SPECT imaging, center of rotation (COR) errors lead to the misalignment of projection data and can potentially degrade the quality of the reconstructed images. In this work, we study the effects of COR errors on cardiac SPECT imaging using simulation, point source, cardiac phantom, and patient studies. For simulation studies, we generate projection data using a uniform MCAT phantom first without modeling any physical effects (NPH), then with the modeling of detector response effect (DR) alone. We then corrupt the projection data with simulated sinusoid and step COR errors. For other studies, we introduce sinusoid COR errors to projection data acquired on SPECT systems. An OSEM algorithm is used for image reconstruction without detector response correction, but with nonuniform attenuation correction when needed. The simulation studies show that, when COR errors increase from 0 to 0.96 cm: 1) sinusoid COR errors in axial direction lead to intensity decrease in the inferoapical region; 2) step COR errors in axial direction lead to intensity decrease in the distal anterior region. The intensity decrease is more severe in images reconstructed from projection data with NPH than with DR; and 3) the effects of COR errors in transaxial direction seem to be insignificant. In other studies, COR errors slightly degrade point source resolution; COR errors of 0.64 cm or above introduce visible but insignificant nonuniformity in the images of uniform cardiac phantom; COR errors up to 0.96 cm in transaxial direction affect the lesion-to-background contrast (LBC) insignificantly in the images of cardiac phantom with defects, and COR errors up to 0.64 cm in axial direction only slightly decrease the LBC. For the patient studies with COR errors up to 0.96 cm, images have the same diagnostic/prognostic values as those without COR errors. This work suggests that COR errors of up to 0.64 cm are not likely to change the clinical applications of cardiac SPECT imaging when using iterative reconstruction algorithm without detector response correction.
引用
收藏
页码:1528 / 1535
页数:8
相关论文
共 50 条
  • [1] Myocardial Perfusion SPECT and Cardiac MR Correlative Imaging
    Prosper, Ashley E.
    Colletti, Patrick M.
    CLINICAL NUCLEAR MEDICINE, 2017, 42 (12) : 941 - 944
  • [2] Establishing a cardiac imaging rotation in radiology residency
    Zaheer, Atif
    Raptopoulos, Vassilios
    ACADEMIC RADIOLOGY, 2006, 13 (07) : 871 - 873
  • [3] Computer Evaluation of a Novel Multipinhole SPECT System for Cardiac Imaging
    Huang, Qiu
    Boutchko, Rostyslav
    Hasegawa, Bruce H.
    Budinger, Thomas F.
    Gullberg, Grant T.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3300 - +
  • [4] Acquisition and Processing Methods for a Bedside Cardiac SPECT Imaging System
    Studenski, Matthew T.
    Gilland, David R.
    Cebula, Alan
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 206 - 213
  • [5] Estimation of dynamic time activity curves from dynamic cardiac SPECT imaging
    Hossain, J.
    Du, Y.
    Links, J.
    Rahmim, A.
    Karakatsanis, N.
    Akhbardeh, A.
    Lyons, J.
    Frey, E. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (08) : 3193 - U501
  • [6] Automatic in-plane rotation for doubly-oblique cardiac imaging
    Kellman, P
    Derbyshire, JA
    McVeigh, ER
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (05) : 612 - 615
  • [7] The Biological Effects of Diagnostic Cardiac Imaging
    Landini, L.
    Ripoli, A.
    Santarelli, M. F.
    Landini, L., Jr.
    Positano, V.
    CURRENT PHARMACEUTICAL DESIGN, 2009, 15 (10) : 1123 - 1130
  • [8] The environmental effects of non-invasive cardiac imaging
    Gardiner, Kelsey
    Hanneman, Kate
    Kozor, Rebecca
    AMERICAN HEART JOURNAL PLUS: CARDIOLOGY RESEARCH AND PRACTICE, 2024, 46
  • [9] Effects of Radiation Exposure From Cardiac Imaging How Good Are the Data?
    Einstein, Andrew J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (06) : 553 - 565
  • [10] Cardiac Imaging 2006
    Colletti, PM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) : S337 - S339