Use of Real-World Data for Enhancing Model Credibility: Applications to Medical Device Development

被引:1
作者
Briant, Paul [1 ]
Bischoff, Jeffrey E. [2 ]
Dharia, Mehul A. [2 ]
Le Naveaux, Franck [3 ]
Li, XueMei [4 ]
Kulkarni, Sanjeev [5 ]
Levine, Danny [6 ]
Ramos, David O. [7 ]
Afshari, Payman [8 ]
机构
[1] Exponent Inc, 149 Commonwealth Dr, Menlo Pk, CA 94025 USA
[2] Zimmer Biomet, 1800 West Ctr St, PL-46580 Warsaw, IN, Poland
[3] Numalogics, 6750 Ave Esplanade,290, Montreal, PQ H2V 1A2, Canada
[4] Abbott Labs, 5050 Nathan Lane North, Plymouth, MN 55442 USA
[5] Neilsoft Inc, 7000 Execut Ctr Dr,Suite 210, Brentwood, TN 37027 USA
[6] Purdue Polytech Inst, 635 South Lafayette Bldg Suite 128, South Bend, IN 46601 USA
[7] Janssen Pharmaceut, Johnson & Johnson, 4691 Karson Creek Dr, Orange Pk, FL 32065 USA
[8] Depuy Synthes, Johnson & Johnson, 325 Paramt Dr, Raynham, MA 02767 USA
来源
JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME | 2022年 / 16卷 / 03期
关键词
TOTAL KNEE REPLACEMENT; TIBIAL TRAY; FRACTURE;
D O I
10.1115/1.4053888
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Evaluating the credibility of computational models used in medical device development is increasingly important as medical devices become more complex and modeling takes on a more critical role in the device development process. While bench-testing based comparisons are common for assessing model credibility and have many advantages, such as control over test specimens and the ability to quantify outputs, the credibility assessments performed with bench tests often do not evaluate the clinical relevance of key aspects of model form (such as boundary conditions, constitutive models/properties, and geometries) selected when simulating in vivo conditions. Real-world data (outcomes data generated through clinical use of a device) offer an opportunity to assess the applicability and clinical relevance of a computational model. Although real-world data are frequently less controlled and more qualitative than benchtop data, real-world data are often a direct assessment of a particular clinical complication and therefore of high clinical relevance. Further, real-world data have the potential to reveal failure modes not previously identified in preclinical failure modes analysis, thereby motivating testing advancements. To review the use of clinical data in medical device modeling, this paper presents a series of examples related to tibial tray fracture that incorporate varying levels of benchtop data and real world data when evaluating model credibility. The merits and drawbacks of the credibility assessment for each example are discussed in order to provide practical and actionable guidance on the use of real-world data for establishing and demonstrating model credibility.
引用
收藏
页数:9
相关论文
共 22 条
  • [1] Fracture of the metal tibial tray after kinematic total knee replacement - A common cause of early aseptic failure
    Abernethy, PJ
    Robinson, CM
    Fowler, RM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (02): : 220 - 225
  • [2] Evaluation of a testing method for the fatigue performance of total knee tibial trays
    Ahir, SP
    Blunn, GW
    Haider, H
    Walker, PS
    [J]. JOURNAL OF BIOMECHANICS, 1999, 32 (10) : 1049 - 1057
  • [3] ASME, 2018, 40 ASME VV
  • [4] ASTM, 2020, ASTM INT CONSHOHOCKE
  • [5] ASTM, 2019, STANDARD PRACTICE CY
  • [6] ASTM International, 2014, F251408 ASTM
  • [7] ASTM International, 2019, F333419 ASTM
  • [8] ASTM International, 2016, STANDARD TEST METHOD
  • [9] Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties
    Banks, S
    Bellemans, J
    Nozaki, H
    Whiteside, LA
    Harman, M
    Hodge, WA
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) : 131 - 138
  • [10] Boran S., 2005, Eur. J. Orthop. Surg. Traumatol., V15, P295