High frequency ultrasound imaging using Fabry-Perot optical etalon

被引:4
|
作者
Ashkenazi, S [1 ]
Witte, R [1 ]
O'Donnell, M [1 ]
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
来源
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2005 | 2005年 / 5697卷
关键词
D O I
10.1117/12.589274
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Optical detection of ultrasound provides a unique and appealing way of forming detector arrays (1D or 2D) using either raster beam scanning or simultaneous array detection exploiting wide area illumination. Etalon based optical techniques are of particular interest, due to their relatively high sensitivity resulting from multiple optical reflections within the resonance structure. Detector arrays formed by etalon based techniques are characterized by high element density and small element active area, which enables high resolution imaging at high ultrasonic frequencies (typically 10-50 MHz). In this paper we present an application of an optical etalon structure for very high frequency ultrasound detection (exceeding 100 MHz). A thin polymer Fabry-Perot etalon (10 mu m thickness) has been fabricated using spin coating of polymer photoresist on a glass substrate and gold evaporation forming partially reflecting mirrors on both faces of the polymer layer. The optical resonator formed by the etalon structure has a measured Q-factor of 300. The characteristic broadband response of the optical signal was demonstrated by insonifying the etalon using two different ultrasound transducers and recording the resulting intensity modulation of optical reflection from the etalon. A focused 10 MHz transducer was used for the low MHz frequency region, and a 50 MHz focused transducer was used for the high frequency region. The optical reflection signal was compared to the pulse/echo signal detected by the same ultrasound transducer. The measured signal to noise ratio of the optically detected signal is comparable to that of the pulse/echo signal in both low and high frequency ranges. The etalon detector was integrated in a photoacoustic imaging system. High resolution images of phantom targets and biological tissue (nerve cord) were obtained. ne additional information of optical absorption obtained by photoacoustic imaging, along with the high resolution detection of the etalon, offer unique advantages for intravascular and neurolocical imaging devices.
引用
收藏
页码:243 / 250
页数:8
相关论文
共 50 条
  • [31] High-performance Fabry-Perot etalon mount for spaceflight
    McKay, JA
    Rees, D
    OPTICAL ENGINEERING, 2000, 39 (01) : 315 - 319
  • [32] Photoacoustic Mouse Brain Imaging Using an Optical Fabry-Perot Interferometric Ultrasound Sensor
    Chen, Yuwen
    Chen, Buhua
    Yu, Tengfei
    Yin, Lu
    Sun, Mingjian
    He, Wen
    Ma, Cheng
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [33] An optical pulse generation technique using two optical phase modulators and a Fabry-Perot etalon
    Akkaya, Ibrahim
    Tozburun, Serhat
    PHYSICS AND SIMULATION OF OPTOELECTRONIC DEVICES XXVIII, 2020, 11274
  • [34] CALIBRATED FABRY-PEROT ETALON AS AN ABSOLUTE FREQUENCY REFERENCE FOR OFDM COMMUNICATIONS
    BOUCHER, R
    VILLENEUVE, B
    BRETON, M
    TETU, M
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1992, 4 (07) : 801 - 804
  • [35] ON THE FREQUENCY-DEPENDENT OPTICAL-LENGTH OF A LASER RESONATOR WITH AN INTERNAL FABRY-PEROT ETALON
    MEHENDALE, SC
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1991, 27 (05) : 1141 - 1142
  • [37] Hybrid Fabry-Perot etalon using an electro-optic polymer for optical modulation
    Gan, Haiyong
    Zhang, Hongxi
    DeRose, Christopher T.
    Norwood, Robert A.
    Fallahi, Mahmoud
    Luo, Jingdong
    Jen, Alex K. -Y.
    Liu, Boyang
    Ho, Seng-Tiong
    Peyghambarian, Nasser
    APPLIED PHYSICS LETTERS, 2006, 89 (14)
  • [38] Small broadband receiving antenna using a Fabry-Perot etalon
    Meyer, GV
    Wittneben, A
    2005 IEEE International Conference on Ultra-Wideband (ICU), 2005, : 190 - 195
  • [39] Liquid Crystal Phase Transitions Using Fabry-Perot Etalon
    Gupta, Suresh Chandra J.
    Journal of Optics (India), 2000, 29 (02): : 53 - 62
  • [40] Phase transition temperatures of LCs using Fabry-Perot etalon
    Gupta, SJ
    Gharde, RA
    Tripathi, AR
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 2001, 364 : 461 - 468