Determination of 1,4-benzodiazepines by high-performance liquid chromatography electrospray tandem mass spectrometry

被引:52
作者
Kleinschnitz, M [1 ]
Herderich, M [1 ]
Schreier, P [1 ]
机构
[1] UNIV WURZBURG,LEHRSTUHL LEBENSMITTELCHEM,D-97074 WURZBURG,GERMANY
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1996年 / 676卷 / 01期
关键词
1,4-benzodiazepines; diazepam; N-desmethyldiazepam; nitrazepam; flunitrazepam; medazepam;
D O I
10.1016/0378-4347(95)00412-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and selective method to determine diazepam, N-desmethyldiazepam, nitrazepam, flunitrazepam and medazepam in human serum and urine was established employing solid-phase extraction and high-performance liquid chromatography-electrospray tandem mass spectrometry (HPLC-ESI-MS-MS) with the selected reaction monitoring (SRM) mode. Using diazepam-d(5) and N-desmethyldiazepam-d(5) as internal standards, recoveries between 90.4 and 109.7% were determined. The routine quantification limit was set at 2 ng/ml for serum and urine at a signal-to-noise ratio of 10:1.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 19 条
  • [1] DETERMINATION OF BENZODIAZEPINES BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY
    BECHET, I
    FILLET, M
    HUBERT, P
    CROMMEN, J
    [J]. ELECTROPHORESIS, 1994, 15 (10) : 1316 - 1321
  • [2] FRAGMENTATION OF 5-PHENYL-1,4-BENZODIAZEPIN-2-ONES - MECHANISM FOR THE FORMATION OF [M-H]+
    BENZ, W
    VANE, FM
    RAPP, U
    [J]. ORGANIC MASS SPECTROMETRY, 1979, 14 (03): : 154 - 159
  • [3] URINARY SCREENING FOR BENZODIAZEPINES WITH RADIORECEPTOR ASSAY - COMPARISON WITH EMIT(R) DAU BENZODIAZEPINE ASSAY AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    BORGGAARD, B
    JOERGENSEN, I
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 1994, 18 (05) : 243 - 246
  • [4] DETERMINATION OF 1,4-BENZODIAZEPINES AND 1,4-BENZODIAZEPINE-2-ONES IN BLOOD BY ELECTRON-CAPTURE GAS-LIQUID-CHROMATOGRAPHY
    DESILVA, JAF
    BEKERSKY, I
    PUGLISI, CV
    BROOKS, MA
    WEINFELD, RE
    [J]. ANALYTICAL CHEMISTRY, 1976, 48 (01) : 10 - 19
  • [5] QUANTITATION BY GAS-CHROMATOGRAPHY WITH SELECTED-ION MONITORING MASS-SPECTROMETRY OF NATURAL DIAZEPAM, N-DESMETHYLDIAZEPAM AND OXAZEPAM IN NORMAL HUMAN SERUM
    DUTHEL, JM
    CONSTANT, H
    VALLON, JJ
    ROCHET, T
    MIACHON, S
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 579 (01): : 85 - 91
  • [6] EBEL S, 1977, DTSCH APOTH ZTG, V40, P1605
  • [7] DETERMINATION OF L-365,260, A NEW CHOLECYSTOKININ RECEPTOR (CCK-B) ANTAGONIST, IN PLASMA BY LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE CHEMICAL IONIZATION MASS-SPECTROMETRY
    GILBERT, JD
    HAND, EL
    YUAN, AS
    OLAH, TV
    COVEY, TR
    [J]. BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (02) : 63 - 68
  • [8] DETERMINATION OF BENZODIAZEPINE RESIDUES IN BIOLOGICAL TISSUES AND FLUIDS BY GAS-LIQUID-CHROMATOGRAPHY
    HOHNE, D
    BOHN, G
    THIER, HP
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 328 (1-2): : 99 - 104
  • [9] JONES CE, 1989, CLIN CHEM, V35, P1394
  • [10] SCREENING, IDENTIFICATION, AND QUANTITATION OF BENZODIAZEPINES IN POSTMORTEM SAMPLES BY HPLC WITH PHOTODIODE-ARRAY DETECTION
    LAMBERT, WE
    MEYER, E
    XUEPING, Y
    DELEENHEER, AP
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 1995, 19 (01) : 35 - 40