Flow injection-chemiluminescence determination of propranolol in pharmaceutical preparations

被引:58
|
作者
Townshend, A
Pulgarín, JAM
Pardo, MTA
机构
[1] Univ Castilla La Mancha, Dept Analyt Chem & Foods Technol, E-13071 Ciudad Real, Spain
[2] Univ Hull, Sch Chem, Kingston Upon Hull HU6 7RX, N Humberside, England
关键词
propranolol; chemiluminescence; flow injection; pharmaceutical formulations;
D O I
10.1016/S0003-2670(03)00664-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and precise continuous-flow method is described for the determination of propranolol based on the chemiluminescence (CL) produced by its reaction with potassium permanganate in a sulphuric acid medium. The optimum chemical conditions for the chemiluminescence emission were investigated. Two manifolds were tested and their characteristics such as the length of the reactor, injection volume and flow rate were compared. When using the selected manifold, propranolol gives a linear calibration graph over the concentration range 1.0-17.5 mg l(-1). The detection limit calculated as proposed by IUPAC was 70 ng ml(-1) and the detection limit calculated as proposed by Clayton was 0.87 mg l(-1). For analysis of 10 solutions of 10.0 mg l(-1) propranolol, if error propagation theory is assumed, the relative error was 0.1%. The standard deviation (S.D.) for 10 replicate samples was 0.07 mg l(-1). The method has been validated versus a published fluorimetric method. The present chemiluminescence procedure was applied to the determination of propranolol in simple British and Spanish pharmaceutical formulations, with excellent recoveries, as the determination is free from interference from common excipients. However, some drugs, such as hydralazine and bendroflumethizide which may also be present in the formulation, increase the emission intensity. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 50 条
  • [21] Flow-injection enhanced chemiluminescence method for determination of ciprofloxacin in pharmaceutical preparations and biological fluids
    Han-Wen Sun
    Li-Qing Li
    Xue-Yan Chen
    Analytical and Bioanalytical Chemistry, 2006, 384 : 1314 - 1319
  • [22] Flow-injection enhanced chemiluminescence method for determination of ciprofloxacin in pharmaceutical preparations and biological fluids
    Sun, HW
    Li, LQ
    Chen, XY
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (06) : 1314 - 1319
  • [23] Flow injection-chemiluminescence determination of phenol using potassium permanganate and formaldehyde system
    Cao, Wei
    Mu, Xuemin
    Yang, Jinghe
    Shi, Wenbo
    Zheng, Yongcun
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2007, 66 (01) : 58 - 62
  • [24] Determination of hydrogen peroxide by flow injection-chemiluminescence using a novel flow-cell reactor in a chemiluminescence detector
    Kawamoto, H
    Nozaki, O
    BUNSEKI KAGAKU, 1999, 48 (05) : 471 - 476
  • [25] Flow injection-chemiluminescence determination of amoxycillin using potassium permanganate and formaldehyde system
    Cao, W
    Yang, JH
    Sun, CX
    Chen, YJ
    Ga, QF
    LUMINESCENCE, 2005, 20 (01) : 20 - 24
  • [26] Determination of piroxicam in pharmaceutical preparations by continuous-flow chemiluminescence
    Murillo Pulgarin, J. A.
    Alanon Molina, A.
    Boras, N.
    ANALYTICAL METHODS, 2010, 2 (01) : 76 - 81
  • [27] Flow Injection Chemiluminescence Determination of Puerarin in Pharmaceutical Preparations Using Eosin Y-Fenton System
    Cai Zhuo
    Zhang Xian
    Lu Dengfeng
    Gan Jingni
    CHINESE JOURNAL OF CHEMISTRY, 2011, 29 (06) : 1261 - 1267
  • [28] Sensitive determination of 2-methoxyestradiol in pharmaceutical preparations and serum samples using flow injection chemiluminescence
    Yao, Hanchun
    Zhang, Min
    Zeng, Wenyuan
    Zeng, Xiaoying
    Zhang, Zhenzhong
    LUMINESCENCE, 2014, 29 (03) : 261 - 265
  • [29] Analytical intercomparison between flow injection-chemiluminescence and flow injection-spectrophotometry for the determination of picomolar concentrations of iron in seawater
    Bowie, AR
    Sedwick, PN
    Worsfold, PJ
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2004, 2 : 42 - 54
  • [30] Flow-Batch Analyzer for the Chemiluminescence Determination of Catecholamines in Pharmaceutical Preparations
    Gruenhut, Marcos
    Martins, Valdomiro L.
    Centurion, Maria E.
    Ugulino Araujo, Mario Cesar
    Fernandez Band, Beatriz S.
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 67 - 81