3D visualization and quantification of rat cortical bone porosity using a desktop micro-CT system: a case study in the tibia

被引:41
作者
Britz, H. M.
Jokihaara, J. [2 ]
Leppanen, O. V. [3 ]
Jarvinen, T. [3 ]
Cooper, D. M. L. [1 ]
机构
[1] Univ Saskatchewan, Dept Anat & Cell Biol, Saskatoon, SK S7N 5E5, Canada
[2] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[3] Univ Tampere, FIN-33101 Tampere, Finland
关键词
Cortical bone; cortical porosity; histology; micro-CT; rat; synchrotron; MICROCOMPUTED TOMOGRAPHY; MORPHOMETRIC-ANALYSIS; COMPUTED TOMOGRAPHY; CANCELLOUS BONE; TRABECULAR BONE; MICROSTRUCTURE; SECTIONS; SCAFFOLDS; THICKNESS; SIZE;
D O I
10.1111/j.1365-2818.2010.03381.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
P>Although micro-computed tomography (micro-CT) has become the gold standard for assessing the 3D structure of trabecular bone, its extension to cortical bone microstructure has been relatively limited. Desktop micro-CT has been employed to assess cortical bone porosity of humans, whereas that of smaller animals, such as mice and rats, has thus far only been imaged using synchrotron-based micro-CT. The goal of this study was to determine if it is possible to visualize and quantify rat cortical porosity using desktop micro-CT. Tibiae (n = 10) from 30-week-old female Sprague-Dawley rats were imaged with micro-CT (3 mu m nominal resolution) and sequential ground sections were then prepared. Bland-Altman plots were constructed to compare per cent porosity and mean canal diameter from micro-CT (3D) versus histology (2D). The mean difference or bias (histology - micro-CT; +/- 95% confidence interval) for per cent porosity was found to be -0.15% (+/- 2.57%), which was not significantly different from zero (P = 0.720). Canal diameter had a bias (+/- 95% confidence interval) of -5.73 mu m (+/- 4.02 mu m) which was found to be significantly different from zero (P < 0.001). The results indicated that cortical porosity in rat bone can indeed be visualized by desktop micro-CT. Quantitative assessment of per cent porosity provided unbiased results, whereas direct analysis of mean canal diameter was overestimated by micro-CT. Thus, although higher resolution, such as that available from synchrotron micro-CT, may ultimately be required for precise geometric measurements, desktop micro-CT - which is far more accessible - is capable of yielding comparable measures of porosity and holds great promise for assessment of the 3D arrangement of cortical porosity in the rat.
引用
收藏
页码:32 / 37
页数:6
相关论文
共 36 条
[31]   Ultrastructural properties in cortical bone vary greatly in two inbred strains of mice as assessed by synchrotron light based micro- and Nano-CT [J].
Schneider, Philipp ;
Stauber, Martin ;
Voide, Romain ;
Stampanoni, Marco ;
Donahue, Leah Rae ;
Mueller, Ralph .
JOURNAL OF BONE AND MINERAL RESEARCH, 2007, 22 (10) :1557-1570
[32]   Simultaneous 3D Visualization and Quantification of Murine Bone and Bone Vasculature Using Micro-Computed Tomography and Vascular Replica [J].
Schneider, Philipp ;
Krucker, Thomas ;
Meyer, Eric ;
Ulmann-Schuler, Alexandra ;
Weber, Bruno ;
Stampanoni, Marco ;
Mueller, Ralph .
MICROSCOPY RESEARCH AND TECHNIQUE, 2009, 72 (09) :690-701
[33]   Computer-assisted 3D reconstruction of serial sections of cortical bone to determine the 3D structure of osteons [J].
Stout, SD ;
Brunsden, BS ;
Hildebolt, CF ;
Commean, PK ;
Smith, KE ;
Tappen, NC .
CALCIFIED TISSUE INTERNATIONAL, 1999, 65 (04) :280-284
[34]   Nondestructive imaging of hominoid dental microstructure using phase contrast X-ray synchrotron microtomography [J].
Tafforeau, Paul ;
Smith, Tanya A. .
JOURNAL OF HUMAN EVOLUTION, 2008, 54 (02) :272-278
[35]   3-DIMENSIONAL STUDIES OF RESORPTION SPACES AND DEVELOPING OSTEONS [J].
TAPPEN, NC .
AMERICAN JOURNAL OF ANATOMY, 1977, 149 (03) :301-332
[36]   Prediction of cortical bone porosity in vitro by microcomputed tomography [J].
Wachter, NJ ;
Augat, P ;
Krischak, GD ;
Mentzel, M ;
Kinzl, L ;
Claes, L .
CALCIFIED TISSUE INTERNATIONAL, 2001, 68 (01) :38-42