3D visualization and quantification of rat cortical bone porosity using a desktop micro-CT system: a case study in the tibia

被引:41
作者
Britz, H. M.
Jokihaara, J. [2 ]
Leppanen, O. V. [3 ]
Jarvinen, T. [3 ]
Cooper, D. M. L. [1 ]
机构
[1] Univ Saskatchewan, Dept Anat & Cell Biol, Saskatoon, SK S7N 5E5, Canada
[2] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[3] Univ Tampere, FIN-33101 Tampere, Finland
关键词
Cortical bone; cortical porosity; histology; micro-CT; rat; synchrotron; MICROCOMPUTED TOMOGRAPHY; MORPHOMETRIC-ANALYSIS; COMPUTED TOMOGRAPHY; CANCELLOUS BONE; TRABECULAR BONE; MICROSTRUCTURE; SECTIONS; SCAFFOLDS; THICKNESS; SIZE;
D O I
10.1111/j.1365-2818.2010.03381.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
P>Although micro-computed tomography (micro-CT) has become the gold standard for assessing the 3D structure of trabecular bone, its extension to cortical bone microstructure has been relatively limited. Desktop micro-CT has been employed to assess cortical bone porosity of humans, whereas that of smaller animals, such as mice and rats, has thus far only been imaged using synchrotron-based micro-CT. The goal of this study was to determine if it is possible to visualize and quantify rat cortical porosity using desktop micro-CT. Tibiae (n = 10) from 30-week-old female Sprague-Dawley rats were imaged with micro-CT (3 mu m nominal resolution) and sequential ground sections were then prepared. Bland-Altman plots were constructed to compare per cent porosity and mean canal diameter from micro-CT (3D) versus histology (2D). The mean difference or bias (histology - micro-CT; +/- 95% confidence interval) for per cent porosity was found to be -0.15% (+/- 2.57%), which was not significantly different from zero (P = 0.720). Canal diameter had a bias (+/- 95% confidence interval) of -5.73 mu m (+/- 4.02 mu m) which was found to be significantly different from zero (P < 0.001). The results indicated that cortical porosity in rat bone can indeed be visualized by desktop micro-CT. Quantitative assessment of per cent porosity provided unbiased results, whereas direct analysis of mean canal diameter was overestimated by micro-CT. Thus, although higher resolution, such as that available from synchrotron micro-CT, may ultimately be required for precise geometric measurements, desktop micro-CT - which is far more accessible - is capable of yielding comparable measures of porosity and holds great promise for assessment of the 3D arrangement of cortical porosity in the rat.
引用
收藏
页码:32 / 37
页数:6
相关论文
共 36 条
[21]   EVALUATION OF A MICROCOMPUTED TOMOGRAPHY SYSTEM TO STUDY TRABECULAR BONE-STRUCTURE [J].
KUHN, JL ;
GOLDSTEIN, SA ;
FELDKAMP, LA ;
GOULET, RW ;
JESION, G .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (06) :833-842
[22]   Biphasic change and disuse-mediated regression of canal network structure in cortical bone of growing rats [J].
Matsumoto, T. ;
Yoshino, M. ;
Uesugi, K. ;
Tanaka, M. .
BONE, 2007, 41 (02) :239-246
[23]   Monochromatic synchrotron radiation μCT reveals disuse-mediated canal network rarefaction in cortical bone of growing rat tibiae [J].
Matsumoto, T ;
Yoshino, M ;
Asano, T ;
Uesugi, K ;
Todoh, M ;
Tanaka, M .
JOURNAL OF APPLIED PHYSIOLOGY, 2006, 100 (01) :274-280
[24]   Robust Pore Size Analysis of Filamentous Networks from Three-Dimensional Confocal Microscopy [J].
Mickel, Walter ;
Muenster, Stefan ;
Jawerth, Louise M. ;
Vader, David A. ;
Weitz, David A. ;
Sheppard, Adrian P. ;
Mecke, Klaus ;
Fabry, Ben ;
Schroeder-Turk, Gerd E. .
BIOPHYSICAL JOURNAL, 2008, 95 (12) :6072-6080
[25]  
Mohsin S., 2002, European Journal of Morphology, V40, P309, DOI 10.1076/ejom.40.5.309.28901
[26]   Morphometric analysis of human bone biopsies:: A quantitative structural comparison of histological sections and micro-computed tomography [J].
Müller, R ;
Van Campenhout, H ;
Van Damme, B ;
Van Der Perre, G ;
Dequeker, J ;
Hildebrand, T ;
Rüegsegger, P .
BONE, 1998, 23 (01) :59-66
[27]  
Muller R, 1996, Technol Health Care, V4, P113
[28]   RELATIONSHIPS BETWEEN SURFACE, VOLUME, AND THICKNESS OF ILIAC TRABECULAR BONE IN AGING AND IN OSTEOPOROSIS - IMPLICATIONS FOR THE MICROANATOMIC AND CELLULAR MECHANISMS OF BONE LOSS [J].
PARFITT, AM ;
MATHEWS, CHE ;
VILLANUEVA, AR ;
KLEEREKOPER, M ;
FRAME, B ;
RAO, DS .
JOURNAL OF CLINICAL INVESTIGATION, 1983, 72 (04) :1396-1409
[29]  
Peyrin F, 2000, CELL MOL BIOL, V46, P1089
[30]   Porosity of human mandibular condylar bone [J].
Renders, G. A. P. ;
Mulder, L. ;
van Ruijven, L. J. ;
van Eijden, T. M. G. J. .
JOURNAL OF ANATOMY, 2007, 210 (03) :239-248