A standard method to calibrate sonochemical efficiency of an individual reaction system

被引:664
作者
Koda, S
Kimura, T
Kondo, T
Mitome, H
机构
[1] Nagoya Univ, Grad Sch Engn, Dept Mol Design & Engn, Chikusa Ku, Nagoya, Aichi 4648603, Japan
[2] Toyama Med & Pharmaceut Univ, Fac Med, Dept Radiol Sci, Toyama 9300194, Japan
[3] Shiga Univ Med Sci, Dept Chem, Otsu, Shiga 5202192, Japan
[4] AIST, Natl Inst Adv Ind Sci & Technol, Moriyam Ku, Nagoya, Aichi 4638560, Japan
关键词
sonochemistry; sonochemical efficiency; KI dosimetry; Fricke dosimetry; decomposition of porphyrin; calorimetry;
D O I
10.1016/S1350-4177(03)00084-1
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Fricke reaction, KI oxidation and decomposition of porphyrin derivatives by use of seven types of sonochemical apparatus in four different laboratories were examined in the range of frequency of 19.5 kHz to 1.2 MHz. The ultrasonic energy dissipated into an apparatus was determined also by calorimetry. Sonochemical efficiency of Fricke reaction and KI oxidation was defined as the number of reacted molecule per unit ultrasonic energy. The sonochemical efficiency is independent of experimental conditions such as the shape of sample cell and irradiation instruments, but depends on the ultrasonic frequency. We propose the KI oxidation dosimetry using 0.1 mol dm(-3) KI solution as a standard method to calibrate the sonochemical efficiency of an individual reaction system. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:149 / 156
页数:8
相关论文
共 43 条
  • [1] Impact of ultrasonic frequency on aqueous sonoluminescence and sonochemistry
    Beckett, MA
    Hua, I
    [J]. JOURNAL OF PHYSICAL CHEMISTRY A, 2001, 105 (15) : 3796 - 3802
  • [2] SONOCHEMISTRY - FROM RESEARCH LABORATORIES TO INDUSTRIAL-PLANTS
    BERLAN, J
    MASON, TJ
    [J]. ULTRASONICS, 1992, 30 (04) : 203 - 212
  • [3] BERLAN J, 1996, ADV SONOCH, V4, P1
  • [4] *RAPPORTS ENTRE LA LONGUEUR DONDE ET LOXYDATION DE LIODURE DE POTASSIUM PAR LES ULTRASONS
    BUSNEL, RG
    PICARD, D
    BOUZIGUES, H
    [J]. JOURNAL DE CHIMIE PHYSIQUE ET DE PHYSICO-CHIMIE BIOLOGIQUE, 1953, 50 (02) : 97 - 101
  • [5] BUSNEL RG, 1952, CR HEBD ACAD SCI, V235, P1257
  • [6] POWER MEASUREMENT IN SONOCHEMISTRY
    CONTAMINE, RF
    WILHELM, AM
    BERLAN, J
    DELMAS, H
    [J]. ULTRASONICS SONOCHEMISTRY, 1995, 2 (01) : S43 - S47
  • [7] Crum LA., 1999, Sonochemistry And Sonoluminescence, DOI DOI 10.1007/978-94-015-9215-4
  • [8] ELPINER IE, 1964, ULTRASOUND PHYSICAL
  • [9] EFFECT OF FREQUENCY ON SONOCHEMICAL REACTIONS .1. OXIDATION OF IODIDE
    ENTEZARI, MH
    KRUUS, P
    [J]. ULTRASONICS SONOCHEMISTRY, 1994, 1 (02) : S75 - S79
  • [10] The effect of frequency on sonochemical reactions .3. Dissociation of carbon disulfide
    Entezari, MH
    Kruus, P
    Otson, R
    [J]. ULTRASONICS SONOCHEMISTRY, 1997, 4 (01) : 49 - 54