Carbon isotope ratio determination and investigation of seized testosterone preparations

被引:35
作者
Forsdahl, Guro [1 ]
Oestreicher, Christian [1 ]
Koller, Martina [1 ]
Gmeiner, Guenter [1 ]
机构
[1] Seibersdorf Lab GmbH, Doping Control Lab, A-2444 Seibersdorf, Austria
关键词
IRMS; testosterone; doping; black market products; ENDOGENOUS URINARY STEROIDS; MASS-SPECTROMETRIC ANALYSIS; DOPING CONTROL PURPOSES; C-13/C-12; RATIOS; SPORT; ANDROSTANEDIOLS; ABUSE;
D O I
10.1002/dta.373
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present study, the content of a number of black market testosterone products collected in Austria has been analyzed. Additionally, C-13/C-12 ratios were measured for testosterone in the products after cleavage of the testosterone ester. The aim was to determine whether some of these products had similar C-13/C-12 ratios to those normally found for endogenous testosterone, which could prevent a positive isotopic ratio mass spectrometric (IRMS) finding in doping control. Moreover, it was investigated to what extent the preparations contained the masking agent epitestosterone, in order to lower the testosterone/epitestosterone (T/E) ratio in urinary steroid profiles. Out of 30 analyzed products, the declared ingredients differed from the actual content in 10 cases. Epitestosterone, however, could not be found in any of the products. The products displayed delta C-13(VPDB) values between -23.6 and -29.4 parts per thousand. For more than half of these products, the values were within a range reported for endogenous urinary steroids. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:814 / 819
页数:6
相关论文
共 26 条
[1]   Screening urine for exogenous testosterone by isotope ratio mass spectrometric analysis of one pregnanediol and two androstanediols [J].
Aguilera, R ;
Catlin, DH ;
Becchi, M ;
Phillips, A ;
Wang, C ;
Swerdloff, RS ;
Pope, HG ;
Hatton, CK .
JOURNAL OF CHROMATOGRAPHY B, 1999, 727 (1-2) :95-105
[2]  
Aguilera R, 1996, J MASS SPECTROM, V31, P169, DOI 10.1002/(SICI)1096-9888(199602)31:2<169::AID-JMS276>3.0.CO
[3]  
2-I
[4]  
Aguilera R, 2001, CLIN CHEM, V47, P292
[5]  
Ayotte Christiane, 2010, Handb Exp Pharmacol, P77, DOI 10.1007/978-3-540-79088-4_4
[6]   Use of isotope ratio mass spectrometry to detect doping with oral testosterone undecanoate:: Inter-individual variability of 13C/12C ratio [J].
Baume, N ;
Saudan, C ;
Desmarchelier, A ;
Strahm, E ;
Sottas, PE ;
Bagutti, C ;
Cauderay, M ;
Schumacher, YO ;
Manyin, P ;
Saugy, M .
STEROIDS, 2006, 71 (05) :364-370
[7]   GAS-CHROMATOGRAPHY COMBUSTION ISOTOPE RATIO MASS-SPECTROMETRY ANALYSIS OF URINARY STEROIDS TO DETECT MISUSE OF TESTOSTERONE IN SPORT [J].
BECCHI, M ;
AGUILERA, R ;
FARIZON, Y ;
FLAMENT, MM ;
CASABIANCA, H ;
JAMES, P .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (04) :304-308
[8]  
Catlin DH, 1997, CLIN CHEM, V43, P1280
[9]   Stable isotope ratio profiling of testosterone preparations [J].
Cawley, Adam ;
Collins, Michael ;
Kazlauskas, Rymantas ;
Handelsman, David J. ;
Heywood, Robert ;
Longworth, Mitchell ;
Arenas-Queralt, Andrea .
DRUG TESTING AND ANALYSIS, 2010, 2 (11-12) :557-567
[10]   Carbon isotope ratio (δ13C) values of urinary steroids for doping control in sport [J].
Cawley, Adam T. ;
Trout, Graham J. ;
Kazlauskas, Rymantas ;
Howe, Christopher J. ;
George, Adrian V. .
STEROIDS, 2009, 74 (03) :379-392