Ion-channel sensing of ferricyanide anion based on a supported bilayer lipid membrane

被引:8
|
作者
Han, XJ [1 ]
Wang, E [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Jilin, Peoples R China
关键词
D O I
10.2116/analsci.17.1171
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ferricyanide anion has usually been used as a marker of ion-channel sensors. In this work we first found that ferricyanide, itself, can act as a stimulus to regulate the permeability of sBLM prepared from didodecyldimethylammonium bromide (a kind of synthetic lipid) on a GC electrode. We used cyclic voltammetry and a.c. impedance to investigate this phenomenon. The interaction between sBLM and ferricyanide concerns time. Furthermore, we developed a sensor for ferricyanide anion. The ion-channel sensor is highly sensitive. It can detect ferricyanide concentration as low as 5 muM.
引用
收藏
页码:1171 / 1174
页数:4
相关论文
共 50 条
  • [1] Ion-Channel Sensing of Ferricyanide Anion Based on a Supported Bilayer Lipid Membrane
    Xiaojun Han
    Erkang Wang
    Analytical Sciences, 2001, 17 : 1171 - 1174
  • [2] Membrane supported bilayer lipid membranes array: preparation, stability and ion-channel insertion
    Favero, G
    D'Annibale, A
    Campanella, L
    Santucci, R
    Ferri, T
    ANALYTICA CHIMICA ACTA, 2002, 460 (01) : 23 - 34
  • [3] Study of the ion-channel behavior on glassy carbon electrode supported bilayer lipid membranes stimulated by perchlorate anion
    Zhang, Zhiquan
    Shi, Jun
    Huang, Weimin
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 55 : 431 - 435
  • [4] ARTIFICIAL ION-CHANNEL PROVIDING ION FLUX ACROSS LIPID BILAYER-MEMBRANE
    KOBUKE, Y
    JOURNAL OF SYNTHETIC ORGANIC CHEMISTRY JAPAN, 1995, 53 (05) : 451 - 460
  • [5] Screening ion-channel ligand interactions with passive pumping in a microfluidic bilayer lipid membrane chip
    Saha, Shimul C.
    Powl, Andrew M.
    Wallace, B. A.
    de Planque, Maurits R. R.
    Morgan, Hywel
    BIOMICROFLUIDICS, 2015, 9 (01):
  • [6] BIOSENSOR DEVELOPMENT WITH A GLUTAMATE RECEPTOR ION-CHANNEL RECONSTITUTED IN A LIPID BILAYER
    UTO, M
    MICHAELIS, EK
    HU, IF
    UMEZAWA, Y
    KUWANA, T
    ANALYTICAL SCIENCES, 1990, 6 (02) : 221 - 225
  • [7] Field-induced reorganization of the neural membrane lipid bilayer: a proposed role in the regulation of ion-channel dynamics
    Price, H
    Wallace, R
    BIOSYSTEMS, 2003, 68 (01) : 67 - 77
  • [8] Micro- and Nano-Technologies for Lipid Bilayer-Based Ion-Channel Functional Assays
    Hirano-Iwata, Ayumi
    Ishinari, Yutaka
    Yamamoto, Hideaki
    Niwano, Michio
    CHEMISTRY-AN ASIAN JOURNAL, 2015, 10 (06) : 1266 - 1274
  • [9] Imaging Amyloid-β Membrane Interactions: Ion-Channel Pores and Lipid-Bilayer Permeability in Alzheimer's Disease
    Viles, John H.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2023, 62 (25)
  • [10] Lipid bilayer mediates ion-channel cooperativity in a model of hair-cell mechanotransduction
    Gianoli, Francesco
    Risler, Thomas
    Kozlov, Andrei S.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2017, 114 (51) : E11010 - E11019