Effect on Thermal Comfort and Energy Consumption of Different Installation Height and Supply Air Angle of Room Air Conditioner by Simulation

被引:0
|
作者
Yang, Zixu [1 ]
Wang, Baolong [1 ]
Shi, Wenxing [1 ]
Li, Xianting [1 ]
机构
[1] Tsinghua Univ, Beijing, Peoples R China
来源
INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES (IAQ 2020), PT 1 | 2021年
关键词
BUILDING ENERGY;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Improving actual operation performance of room air conditioners (RAC) shows great importance in the indoor environment and building energy conversation. The installation height and supply air angle of the indoor unit of RAC directly affect thermal comfort and energy performance in heating conditions. In this paper, a combined simulation of building, indoor air distribution, and performance of RAC is proposed to investigate the influence of installation height and supply air angle. The combined simulation model was validated by experiment results. Based on the simulation model, a living room in Shanghai was analyzed. The results indicated that the indoor temperature and the heat transfer coefficient of the external wall vary from different installation heights and supply air angles. When the RAC was installed at a relatively low height, the return air temperature was significantly lower than that in higher height, and the thermal environment was more comfortable. Moreover, the heating capacity of RAC was increased by about 12.2%, and the energy efficiency ratio was increased by approximately 3.5% at the lower height position. The results highlight the issues of installation height and supply air angle, in order to improve indoor thermal comfort and optimize the actual performance of RACs.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Effect of installation height of indoor unit on field heating performance of room air conditioner
    Yang, Zixu
    Xiao, Hansong
    Ji, Changqi
    Wang, Baolong
    Shi, Wenxing
    JOURNAL OF BUILDING ENGINEERING, 2020, 32
  • [2] Influence of Household Heat Pump Air Conditioner Air Supply Modes on Thermal Comfort
    Dong M.
    Tan J.
    Xiao B.
    Li B.
    Zhao S.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2022, 49 (01): : 183 - 191
  • [3] Investigation of thermal comfort of room air conditioner during heating season
    Yang, Zixu
    Dong, Xian
    Xiao, Hansong
    Sun, Hongli
    Wang, Baolong
    Shi, Wenxing
    Li, Xianting
    BUILDING AND ENVIRONMENT, 2022, 207
  • [4] Energy conservation and thermal environment analysis of room air conditioner with intermittent supply airflow
    Fan, Yunqing
    Toyoshima, Masaki
    Saito, Makoto
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2018, 13 (01) : 84 - 91
  • [5] METHOD FOR CALCULATING ENERGY-CONSUMPTION OF A ROOM AIR CONDITIONER
    BEARD, WL
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1976, 18 (12): : 42 - 42
  • [6] Analysis and Optimization of Varying Door and Windows Opening on Energy Consumption and Thermal Comfort in Air-Conditioner Office
    Shen, Chunming
    Wang, Zhicheng
    Yao, Kailu
    Yuan, Wenying
    Sun, Fangtian
    Journal of Engineering Science and Technology Review, 2024, 17 (03) : 217 - 227
  • [7] Effects of return air vent height on energy consumption, thermal comfort conditions and indoor air quality in an under floor air distribution system
    Heidarinejad, Ghassem
    Fathollahzadeh, Mohammad Hassan
    Pasdarshahri, Hadi
    ENERGY AND BUILDINGS, 2015, 97 : 155 - 161
  • [8] Small fan assisted air conditioner for thermal comfort and energy saving in Thailand
    Atthajariyakul, Surat
    Lertsatittanakorn, Charoenporn
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (10) : 2499 - 2504
  • [9] Effect of Supply Air Temperature on Indoor Thermal Comfort in a Room with Radiant Heating and Mechanical Ventilation
    Wu, Xiaozhou
    Liu, Yujia
    Liu, Genglin
    Wang, Fenghao
    Wang, Zhihua
    IMPROVING RESIDENTIAL ENERGY EFFICIENCY INTERNATIONAL CONFERENCE, IREE 2017, 2017, 121 : 206 - 213
  • [10] Efficiency evaluation of a floor standing air conditioner with different installation positions and air supply parameters applied to a large laboratory
    Xin, Song
    Xu, Hong
    Li, Sasa
    Wang, Wenhao
    Guo, Jianghui
    Yang, Wenyu
    JOURNAL OF BUILDING ENGINEERING, 2020, 32 (32):