Thermal and environmental evaluation of mid-rise social housing retrofit under different climate conditions

被引:16
作者
Flamant, Gilles [1 ]
Bustamante, Waldo [1 ,2 ]
Schmitt, Cristian [2 ]
Bunster, Victor [3 ,4 ]
Osorio, Cesar [1 ,2 ]
机构
[1] Pontificia Univ Catolica Chile, Ctr Sustainable Urban Dev CEDEUS, Comendador 1916, Santiago 7520245, RM, Chile
[2] Pontificia Univ Catolica Chile, Sch Architecture, Comendador 1916, Santiago 7520245, RM, Chile
[3] Monash Univ, Sch Architecture, 900 Dandenong Rd, Caulfield, Vic 3145, Australia
[4] Monash Univ, Sch Civil Engn, 49 Rainforest Walk, Clayton, Vic 3800, Australia
关键词
Energy retrofit; Social housing; Building extension; Summer comfort; Life cycle analysis; LIFE-CYCLE ASSESSMENT; ENERGY-EFFICIENCY; RENOVATION; BUILDINGS; BEHAVIOR; LCA;
D O I
10.1016/j.jobe.2021.103724
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A significant share of the global housing stock lacks minimum residential quality standards. This has prompted the emergence of schemes to meet the needs of current occupants and country-specific carbon targets. Energy retrofitting, in this context, is a cornerstone for initiatives aimed at improving the indoor environmental quality of residential buildings while reducing environmental impacts and costs associated with space conditioning. This study explores different energy retrofitting solutions to the CORVI 1020 scheme, an emblematic mass social housing scheme that was heavily replicated in Chile disregarding local environmental conditions. Building energy simulation and life cycle assessment are used to evaluate three retrofitting scenarios under four contrasting climatic conditions. These scenarios reflect conditions that can be achieved under current subsidized schemes, including moderate and high-performance envelope improvements, with and without a sunspace extension. The scenarios are finetuned to minimize heating demand in winter and overheating risks in summer. Overall, the high-performance solution without sunspace extension outperforms other scenarios across climates and metrics. This study contributes to the development of strategies to improve residential quality and environmental performance in mass housing from a multi-variable perspective.
引用
收藏
页数:18
相关论文
共 86 条
[1]   Easy to implement ventilated sunspace for energy retrofit of condominium buildings with balconies [J].
Allesina, Giulio ;
Ferrari, Chiara ;
Muscio, Alberto ;
Pedrazzi, Simone .
RENEWABLE ENERGY, 2019, 141 :541-548
[2]   Recent developments, future challenges and new research directions in LCA of buildings: A critical review [J].
Anand, Chirjiv Kaur ;
Amor, Ben .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 67 :408-416
[3]  
[Anonymous], 2019, 167981 BS EN, pM1
[4]  
[Anonymous], 2007, BS EN 15251
[5]  
[Anonymous], 2014, VIV SOC COPR
[6]  
[Anonymous], 2013, The Limits of Thermal Comfort: Avoiding Overheating in European Buildings
[7]  
[Anonymous], 2017, D S N 18 PROGR REG C
[8]   Multi-objective optimization coupled with life cycle assessment for retrofitting buildings [J].
Antipova, Ekaterina ;
Boer, Dieter p ;
Guillen-Gosalbez, Gonzalo ;
Cabeza, Luisa F. ;
Jimenez, Laureano .
ENERGY AND BUILDINGS, 2014, 82 :92-99
[9]   Rooftop extension as a solution to reach nZEB in building renovation. Application through typology classification at a neighborhood level [J].
Aparicio-Gonzalez, Elena ;
Domingo-Irigoyen, Silvia ;
Sanchez-Ostiz, Ana .
SUSTAINABLE CITIES AND SOCIETY, 2020, 57
[10]  
Aravena S., 2005, Los con techo. Un desafio para la politica de vivienda social, P125