A Probabilistic Model for Automatic Segmentation of the Esophagus in 3-D CT Scans

被引:19
作者
Feulner, Johannes [1 ,3 ]
Zhou, S. Kevin [2 ]
Hammon, Matthias [4 ]
Seifert, Sascha [3 ]
Huber, Martin [3 ]
Comaniciu, Dorin [2 ]
Hornegger, Joachim [1 ]
Cavallaro, Alexander [4 ]
机构
[1] Univ Erlangen Nurnberg, Pattern Recognit Lab, D-91058 Erlangen, Germany
[2] Siemens Corp Res, Princeton, NJ 08540 USA
[3] Siemens Corp Technol, D-91058 Erlangen, Germany
[4] Univ Erlangen Nurnberg, Inst Radiol, D-91054 Erlangen, Germany
关键词
Esophagus; Markov chain; segmentation; tracking; tubular structure;
D O I
10.1109/TMI.2011.2112372
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Being able to segment the esophagus without user interaction from 3-D CT data is of high value to radiologists during oncological examinations of the mediastinum. The segmentation can serve as a guideline and prevent confusion with pathological tissue. However, limited contrast to surrounding structures and versatile shape and appearance make segmentation a challenging problem. This paper presents a multistep method. First, a detector that is trained to learn a discriminative model of the appearance is combined with an explicit model of the distribution of respiratory and esophageal air. In the next step, prior shape knowledge is incorporated using a Markov chain model. We follow a "detect and connect" approach to obtain the maximum a posteriori estimate of the approximate esophagus shape from hypothesis about the esophagus contour in axial image slices. Finally, the surface of this approximation is nonrigidly deformed to better fit the boundary of the organ. The method is compared to an alternative approach that uses a particle filter instead of a Markov chain to infer the approximate esophagus shape, to the performance of a human observer and also to state of the art methods, which are all semiautomatic. Cross-validation on 144 CT scans showed that the Markov chain based approach clearly outperforms the particle filter. It segments the esophagus with a mean error of 1.80 mm in less than 16 s on a standard PC. This is only 1 mm above the interobserver variability and can compete with the results of previously published semiautomatic methods.
引用
收藏
页码:1252 / 1264
页数:13
相关论文
共 20 条
  • [1] [Anonymous], 1980, MARKOV RANDOM FIELDS, DOI DOI 10.1090/CONM/001
  • [2] Tumors of the mediastinum
    Duwe, BV
    Sterman, DH
    Musani, AI
    [J]. CHEST, 2005, 128 (04) : 2893 - 2909
  • [3] Fan B, 2007, IEEE 2007 INTERNATIONAL SYMPOSIUM ON MICROWAVE, ANTENNA, PROPAGATION AND EMC TECHNOLOGIES FOR WIRELESS COMMUNICATIONS, VOLS I AND II, P1
  • [4] Feulner J, 2010, LECT NOTES COMPUT SC, V6361, P95
  • [5] Feulner J, 2009, LECT NOTES COMPUT SC, V5761, P255, DOI 10.1007/978-3-642-04268-3_32
  • [6] Fieselmann A., 2008, BILDVERARBEITUNG F R, P247, DOI [10.1007/978-3-540-78640-5_50, DOI 10.1007/978-3-540-78640-5_50]
  • [7] Fieselmann A., 2008, BILDVERARBEITUNG MED, P397
  • [8] Direct least square fitting of ellipses
    Fitzgibbon, A
    Pilu, M
    Fisher, RB
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1999, 21 (05) : 476 - 480
  • [9] Florin C, 2005, LECT NOTES COMPUT SC, V3749, P246
  • [10] Semi-automated CT segmentation using optic flow and Fourier interpolation techniques
    Huang, Tzung-Chi
    Zhang, Geoffrey
    Guerrero, Thomas
    Starkschall, George
    Lin, Kan-Ping
    Forster, Ken
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2006, 84 (2-3) : 124 - 134