3D intrastomal ultrasonography, an instrument for detecting stoma-related fistula

被引:3
作者
Gunnarsson, U. [3 ]
Strigard, K. [1 ,2 ,3 ]
机构
[1] Umea Univ, Dept Surg & Perioperat Sci, S-90185 Umea, Sweden
[2] Umea Univ Hosp, S-90185 Umea, Sweden
[3] Karolinska Univ, Huddinge Hosp, Div Surg, Dept Clin Sci Intervent & Technol,CLINTEC,Karolin, Stockholm, Sweden
关键词
3D ultrasonography; Stoma; IPOM mesh; Inflammatory bowel disease; PARASTOMAL HERNIA; REPAIR; SITE; MESH;
D O I
10.1007/s10151-012-0821-x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
The aim of the present study was to evaluate the recently developed 3D intrastomal ultrasonography in diagnosing stoma-associated complaints and suspected complications after parastomal hernia repair such as peristomal fistula and abscesses. 3D intrastomal ultrasonography was used to image peristomal tissue in two patients with complaints after parastomal hernia repair performed with IPOM (intraperitoneal onlay mesh). One patient had ulcerative colitis and one Crohn's disease. Both patients were investigated because of pain and in one case also signs of a subcutaneous abscess. Intrastomal ultrasonography revealed fistulas connected to the intestinal segment leading to the stoma in both cases. Both cases also showed signs of a fistula descending to the abdominal cavity. In one case, a subcutaneous abscess was identified and in the other a small abscess adjacent to the fistula and the edge of the fascia. Stoma complaints after surgery for parastomal hernia with implantation of IPOM mesh can be diagnosed using 3D intrastomal ultrasonography. This new 3D technique for imaging intrastomal hernia can be used to complement traditional methods in the detection of stoma-associated abscesses and fistulas with or without foreign material such as mesh.
引用
收藏
页码:233 / 236
页数:4
相关论文
共 16 条
[1]  
Aldridge A J, 2001, Hernia, V5, P110
[2]   Parastomal hernia [J].
Carne, PWG ;
Robertson, GM ;
Frizelle, FA .
BRITISH JOURNAL OF SURGERY, 2003, 90 (07) :784-793
[3]   Enterostomy site hernias: A clinical and computerized tomographic evaluation [J].
Cingi, Asim ;
Cakir, Tebessum ;
Sever, Ali ;
Aktan, A. Ozdemir .
DISEASES OF THE COLON & RECTUM, 2006, 49 (10) :1559-1563
[4]  
El Mouhadi Sanaa, 2011, AJR Am J Roentgenol, V196, P577, DOI 10.2214/AJR.10.4894
[5]  
Goligher JC, 1985, SURG ANUS RECTUM COL, P703
[6]   PERIILEOSTOMY FISTULAS IN CROHNS-DISEASE [J].
GREENSTEIN, AJ ;
DICKER, A ;
MEYERS, S ;
AUFSES, AH .
ANNALS OF SURGERY, 1983, 197 (02) :179-182
[7]   Imaging of parastomal hernia using three-dimensional intrastomal ultrasonography [J].
Gurmu, A. ;
Gunnarsson, U. ;
Strigard, K. .
BRITISH JOURNAL OF SURGERY, 2011, 98 (07) :1026-1029
[8]   The inter-observer reliability is very low at clinical examination of parastomal hernia [J].
Gurmu, Ambatchew ;
Matthiessen, Peter ;
Nilsson, Sven ;
Pahlman, Lars ;
Rutegard, Jorgen ;
Gunnarsson, Ulf .
INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 2011, 26 (01) :89-95
[9]   Three-dimensional endoanal ultrasonographic assessment of an anal fistula with and without H2O2 enhancement [J].
Kim, Yung ;
Park, Young Jin .
WORLD JOURNAL OF GASTROENTEROLOGY, 2009, 15 (38) :4810-4815
[10]   Laparoscopic parastomal hernia repair [J].
LeBlanc K.A. ;
Bellanger D.E. ;
Whitaker J.M. ;
Hausmann M.G. .
Hernia, 2005, 9 (2) :140-144