The use of a fluorescent bacteriophage assay for detection of Escherichia coli O157:H7 in inoculated ground beef and raw milk

被引:75
作者
Goodridge, L
Chen, JR
Griffiths, M [1 ]
机构
[1] Univ Guelph, Dept Food Sci, Guelph, ON N1G 2W1, Canada
[2] Univ Georgia, Ctr Food Safety & Qual Enhancement, Griffin, GA 30223 USA
关键词
fluorescent; bacteriophage; detection; Escherichia coli O157 : H7; ground beef; raw milk;
D O I
10.1016/S0168-1605(99)00010-0
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The objective of this study was to develop a fluorescent bacteriophage assay (FBA) for the detection of E. coli O157:H7 in ground beef and raw milk. The FBA is a two step assay that combines immunomagnetic separation, to separate the target organism from mixed culture, with a highly specific fluorescently stained bacteriophage to label the E. coli O157:H7 cells. When used in conjunction with flow cytometry, the FBA was able to detect 2.2 CFU/g of artificially contaminated ground beef following a 6 h enrichment. Between 10(1) and 10(2) CFU/ml of artificially contaminated raw milk were detectable after a 10 h enrichment step. The results show that the FBA is potentially useful as a rapid technique for the preliminary detection of E. coli O157:H7 in food. (C) 1999 Elsevier Science B.V. All rights reserved.