Virtual Monochromatic Imaging in Dual-source and Dual-energy CT for Visualization of Acute Ischemic Stroke

被引:5
作者
Hara, Hidetake [1 ]
Muraishi, Hiroshi [1 ]
Matsuzawa, Hiroki [2 ]
Inoue, Toshiyuki [3 ]
Nakajima, Yasuo [3 ]
Satoh, Hitoshi [4 ]
Abe, Shinji [4 ]
机构
[1] Kitasato Univ, Sch Allied Hlth Sci, Sagamihara, Kanagawa 2520373, Japan
[2] Saitama Med Univ, Gen Med Ctr, Kawagoe, Saitama 3508550, Japan
[3] St Marianna Univ, Sch Med, Dept Radiol, Kawasaki, Kanagawa 2168511, Japan
[4] Ibaraki Prefectural Univ Hlth Sci, Sch Hlth Sci, Ami, Ibaraki 3000394, Japan
关键词
Dual-energy CT; Acute ischemic stroke; Virtual monochromatic imaging; QUALITY;
D O I
10.3938/jkps.67.103
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We have recently developed a phantom that simulates acute ischemic stroke. We attempted to visualize an acute-stage cerebral infarction by using dual-energy Computed tomography (DECT) to obtain virtual monochromatic images of this phantom. Virtual monochromatic images were created by using DECT voltages from 40 to 100 keV in steps of 10 keV and from 60 to 80 keV in steps of 1 keV, under three conditions of the tube voltage with thin (Sn) filters. Calculation of the CNR values allowed us to evaluate the visualization of acute-stage cerebral infarction. The CNR value of a virtual monochromatic image was the highest at 68 keV under 80 kV / Sn 140 kV, at 72 keV under 100 kV / Sn 140 kV, and at 67 keV under 140 kV / 80 kV. The CNR values of virtual monochromatic images at voltages between 65 and 75 keV were significantly higher than those obtained for all other created images. Therefore, the optimal conditions for visualizing acute ischemic stroke were achievable.
引用
收藏
页码:103 / 107
页数:5
相关论文
共 10 条
[1]  
Hara H., 2010, ST MARIANNA MED J, V39, P9
[2]  
Hara H., 2013, JPN J MED PHYS, V33, P124
[3]  
Hara H., 2011, AOCMP P, V6
[4]  
Johnson TRC, 2011, MED RADIOL DIAGN IMA, P1, DOI 10.1007/978-3-642-01740-7
[5]   Preliminary report on virtual monochromatic spectral imaging with fast kVp switching dual energy head CT: comparable image quality to that of 120-kVp CT without increasing the radiation dose [J].
Kamiya, Kouhei ;
Kunimatsu, Akira ;
Mori, Harushi ;
Sato, Jiro ;
Akahane, Masaaki ;
Yamakawa, Takana ;
Ohtomo, Kuni .
JAPANESE JOURNAL OF RADIOLOGY, 2013, 31 (04) :293-298
[6]   TISSUE-PLASMINOGEN ACTIVATOR FOR ACUTE ISCHEMIC STROKE [J].
MARLER, JR ;
BROTT, T ;
BRODERICK, J ;
KOTHARI, R ;
ODONOGHUE, M ;
BARSAN, W ;
TOMSICK, T ;
SPILKER, J ;
MILLER, R ;
SAUERBECK, L ;
JARRELL, J ;
KELLY, J ;
PERKINS, T ;
MCDONALD, T ;
RORICK, M ;
HICKEY, C ;
ARMITAGE, J ;
PERRY, C ;
THALINGER, K ;
RHUDE, R ;
SCHILL, J ;
BECKER, PS ;
HEATH, RS ;
ADAMS, D ;
REED, R ;
KLEI, M ;
HUGHES, S ;
ANTHONY, J ;
BAUDENDISTEL, D ;
ZADICOFF, C ;
RYMER, M ;
BETTINGER, I ;
LAUBINGER, P ;
SCHMERLER, M ;
MEIROSE, G ;
LYDEN, P ;
RAPP, K ;
BABCOCK, T ;
DAUM, P ;
PERSONA, D ;
BRODY, M ;
JACKSON, C ;
LEWIS, S ;
LISS, J ;
MAHDAVI, Z ;
ROTHROCK, J ;
TOM, T ;
ZWEIFLER, R ;
DUNFORD, J ;
ZIVIN, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 333 (24) :1581-1587
[7]  
Tanaka C, 2006, AM J NEURORADIOL, V27, P40
[8]  
The National Institute of Neurological disorders and Stroke rt-PA Study Group, 1995, IFMBE P, V333, P1581
[9]   Virtual monochromatic imaging in dual-source dual-energy CT: Radiation dose and image quality [J].
Yu, Lifeng ;
Christner, Jodie A. ;
Leng, Shuai ;
Wang, Jia ;
Fletcher, Joel G. ;
McCollough, Cynthia H. .
MEDICAL PHYSICS, 2011, 38 (12) :6371-6379
[10]   Image quality optimization and evaluation of linearly mixed images in dual-source, dual-energy CT [J].
Yu, Lifeng ;
Primak, Andrew N. ;
Liu, Xin ;
McCollough, Cynthia H. .
MEDICAL PHYSICS, 2009, 36 (03) :1019-1024