Automatic filtering of outliers in RR intervals before analysis of heart rate variability in Holter recordings: a comparison with carefully edited data

被引:47
作者
Karlsson, Marcus [1 ,2 ]
Hornsten, Rolf [3 ]
Rydberg, Annika [4 ]
Wiklund, Urban [1 ,2 ]
机构
[1] Umea Univ, Dept Radiat Sci, Umea, Sweden
[2] Umea Univ, Ctr Biomed Engn & Phys, Umea, Sweden
[3] Umea Univ, Clin Physiol & Heart Ctr, Dept Surg & Perioperat Sci, Umea, Sweden
[4] Umea Univ, Dept Clin Sci, Pediat Cardiol Sect, Umea, Sweden
关键词
COMPUTERIZED ANALYSIS; GENDER; ERRORS; BEAT;
D O I
10.1186/1475-925X-11-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Undetected arrhythmic beats seriously affect the power spectrum of the heart rate variability (HRV). Therefore, the series of RR intervals are normally carefully edited before HRV is analysed, but this is a time consuming procedure when 24-hours recordings are analysed. Alternatively, different methods can be used for automatic removal of arrhythmic beats and artefacts. This study compared common frequency domain indices of HRV when determined from manually edited and automatically filtered RR intervals. Methods and Results: Twenty-four hours Holter recordings were available from 140 healthy subjects of age 1-75 years. An experienced technician carefully edited all recordings. Automatic filtering was performed using a recursive procedure where RR intervals were removed if they differed from the mean of the surrounding RR intervals with more than a predetermined limit (ranging from 10% to 50%). The filtering algorithm was evaluated by replacing 1% of the beats with synthesised ectopic beats. Power spectral analysis was performed before and after filtering of both the original edited data and the noisy data set. The results from the analysis using the noisy data were used to define an age-based filtering threshold. The age-based filtration was evaluated with completely unedited data, generated by removing all annotations from the series of RR intervals, and then comparing the resulting HRV indices with those obtained using edited data. The results showed equivalent results after age-based filtration of both the edited and unedited data sets, where the differences in HRV indices obtained by different preprocessing methods were small compared to the mean values within each age group. Conclusions: The study showed that it might not be necessary to perform the time-consuming careful editing of all detected heartbeats before HRV is analysed in Holter recordings. In most subjects, it is sufficient to perform the regular editing needed for valid arrhythmia analyses, and then remove undetected ectopic beats and artefacts by age-based filtration of the series of RR intervals, particularly in subjects older than 30 years.
引用
收藏
页数:12
相关论文
共 14 条
[1]   Effects of Gender and Aging on Differential Autonomic Responses to Orthostatic Maneuvers [J].
Barantke, Melanie ;
Krauss, Timothy ;
Ortak, Jasmin ;
Lieb, Wolfgang ;
Reppel, Michael ;
Burgdorf, Christof ;
Pramstaller, Peter P. ;
Schunkert, Heribert ;
Bonnemeier, Hendrik .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2008, 19 (12) :1296-1303
[2]  
Camm AJ, 1996, CIRCULATION, V93, P1043
[3]   Quantifying errors in spectral estimates of HRV due to beat, replacement and resampling [J].
Clifford, GD ;
Tarassenko, L .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (04) :630-638
[4]   Outcome of heart rate variability and ventricular late potentials after liver transplantation for familial amyloidotic polyneuropathy [J].
Hornsten, Rolf ;
Suhr, Ole B. ;
Jensen, Steen M. ;
Wiklund, Urban .
AMYLOID-JOURNAL OF PROTEIN FOLDING DISORDERS, 2008, 15 (03) :187-195
[5]   Automatic measurement of long-term heart rate variability by implanted single-chamber devices [J].
Malik, M ;
Padmanabhan, V ;
Olson, WH .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (05) :585-594
[6]  
MYERS G, 1993, J ELECTROCARDIOL, V25, P214
[7]   A COMPARISON OF THE 2 ONE-SIDED TESTS PROCEDURE AND THE POWER APPROACH FOR ASSESSING THE EQUIVALENCE OF AVERAGE BIOAVAILABILITY [J].
SCHUIRMANN, DJ .
JOURNAL OF PHARMACOKINETICS AND BIOPHARMACEUTICS, 1987, 15 (06) :657-680
[8]   Traditional and nonlinear heart rate variability are each independently associated with mortality after myocardial infarction [J].
Stein, PK ;
Domitrovich, PP ;
Huikuri, HV ;
Kleiger, RE .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (01) :13-20
[9]   Automatic computerized analysis of heart rate variability with digital filtering of ectopic beats [J].
Storck, N ;
Ericson, M ;
Lindblad, LE ;
Jensen-Urstad, M .
CLINICAL PHYSIOLOGY, 2001, 21 (01) :15-24
[10]   Twenty-four hour time domain heart rate variability and heart rate: Relations to age and gender over nine decades [J].
Umetani, K ;
Singer, DH ;
McCraty, R ;
Atkinson, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (03) :593-601