Motion artifacts occurring at the lung/diaphragm interface using 4D CT attenuation correction of 4D PET scans

被引:20
作者
Killoran, Joseph H. [1 ]
Gerbaudo, Victor H. [2 ]
Mamede, Marcelo [2 ]
Ionascu, Dan [1 ]
Park, Sang-June [1 ]
Berbeco, Ross [1 ]
机构
[1] Dana Farber Brigham & Womens Canc Ctr, Dept Radiat Oncol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Dept Radiol, Brigham & Womens Hosp,Div Nucl Med, Boston, MA 02115 USA
关键词
4D PET; motion artifacts; attenuation correction; CELL LUNG-CANCER; RESPIRATORY MOTION; VOLUME DELINEATION; TUMOR MOTION; FDG-PET/CT; RADIOTHERAPY; IMPACT; IMAGES; LIVER; 3D;
D O I
10.1120/jacmp.v12i4.3502
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For PET/CT, fast CT acquisition time can lead to errors in attenuation correction, particularly at the lung/diaphragm interface. Gated 4D PET can reduce motion artifacts, though residual artifacts may persist depending on the CT dataset used for attenuation correction. We performed phantom studies to evaluate 4D PET images of targets near a density interface using three different methods for attenuation correction: a single 3D CT (3D CTAC), an averaged 4D CT (CINE CTAC), and a fully phase matched 4D CT (4D CTAC). A phantom was designed with two density regions corresponding to diaphragm and lung. An 8 mL sphere phantom loaded with 18F-FDG was used to represent a lung tumor and background FDG included at an 8:1 ratio. Motion patterns of sin(x) and sin(4)(x) were used for dynamic studies. Image data was acquired using a GE Discovery DVCT-PET/CT scanner. Attenuation correction methods were compared based on normalized recovery coefficient (NRC), as well as a novel quantity "fixed activity volume" (FAV) introduced in our report. Image metrics were compared to those determined from a 3D PET scan with no motion present (3D STATIC). Values of FAV and NRC showed significant variation over the motion cycle when corrected by 3D CTAC images. 4D CTAC- and CINE CTAC-corrected PET images reduced these motion artifacts. The amount of artifact reduction is greater when the target is surrounded by lower density material and when motion was based on sin4(x). 4D CTAC reduced artifacts more than CINE CTAC for most scenarios. For a target surrounded by water equivalent material, there was no advantage to 4D CTAC over CINE CTAC when using the sin(x) motion pattern. Attenuation correction using both 4D CTAC or CINE CTAC can reduce motion artifacts in regions that include a tissue interface such as the lung/diaphragm border. 4D CTAC is more effective than CINE CTAC at reducing artifacts in some, but not all, scenarios.
引用
收藏
页码:261 / 274
页数:14
相关论文
共 28 条
[1]   Cine CT for attenuation correction in cardiac PET/CT [J].
Alessio, Adam M. ;
Kohmyer, Steve ;
Branch, Kelley ;
Chen, Grace ;
Caldwell, James ;
Kinahan, Paul .
JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (05) :794-801
[2]   The contribution of integrated PET/CT to the evolving definition of treatment volumes in radiation treatment planning in lung cancer [J].
Ashamalla, H ;
Rafla, S ;
Parikh, K ;
Mokhtar, B ;
Goswami, G ;
Kambam, S ;
Abdel-Dayem, H ;
Guirguis, A ;
Ross, P ;
Evola, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (04) :1016-1023
[3]   Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology [J].
Beyer, T ;
Antoch, G ;
Blodgett, T ;
Freudenberg, LF ;
Akhurst, T ;
Mueller, S .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) :588-596
[4]  
Biehl KJ, 2006, J NUCL MED, V47, P1808
[5]   Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer [J].
Bradley, J ;
Thorstad, WL ;
Mutic, S ;
Miller, TR ;
Dehdashti, F ;
Siegel, BA ;
Bosch, W ;
Bertrand, RJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (01) :78-86
[6]   Local motion correction for lung tumours in PET/CT-first results [J].
Bundschuh, Ralph A. ;
Martinez-Moeller, Axel ;
Essler, Markus ;
Nekolla, Stephan G. ;
Ziegler, Sibylle I. ;
Schwaiger, Markus .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (11) :1981-1988
[7]   PET-CT: accuracy of PET and CT spatial registration of lung lesions [J].
Cohade, C ;
Osman, M ;
Marshall, LT ;
Wahl, RL .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (05) :721-726
[8]  
Erdi YE, 2004, J NUCL MED, V45, P1287
[9]   Impact of FDG-PET/CT on radiotherapy volume delineation in non-small-cell lung cancer and correlation of imaging stage with pathologic findings [J].
Faria, Sergio L. ;
Menard, Sonia ;
Devic, Slobodan ;
Sirois, Christian ;
Souhami, Luis ;
Lisbona, Robert ;
Freeman, Carolyn R. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04) :1035-1038
[10]   Respiration-induced attenuation artifact at PET/CT: Technical considerations [J].
Goerres, GW ;
Burger, C ;
Kamel, E ;
Seifert, B ;
Kaim, AH ;
Buck, A ;
Buehler, TC ;
von Schulthess, GK .
RADIOLOGY, 2003, 226 (03) :906-910